Quantitative myocardial perfusion imaging using rapid kVp switch dual-energy CT: Preliminary experience

被引:49
|
作者
So, Aaron [1 ,2 ]
Lee, Ting-Yim [1 ,2 ]
Imai, Yasuhiro [3 ]
Narayanan, Suresh [3 ]
Hsieh, Jiang [3 ]
Kramer, John [3 ]
Procknow, Karen [3 ]
Leipsic, Jonathon [4 ]
LaBounty, Troy [5 ]
Min, James
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Lawson Hlth Res Inst, London, ON, Canada
[3] GE Healthcare, CT Engn, Waukesha, WI USA
[4] St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
[5] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
基金
加拿大健康研究院;
关键词
Quantitative myocardial CT perfusion; Beam-hardening artifact; Beam-hardening correction; Single-energy CT; Dual-energy CT; CONVENTIONAL CORONARY-ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; STRESS; ISCHEMIA; EXTENT; SPECT; HEART; REST;
D O I
10.1016/j.jcct.2011.10.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Quantitative myocardial CT perfusion (CTP) is susceptible to beam-hardening (BH) artifact from conventional single-energy (kVp) CT (SECT) scanning, which can mimic perfusion deficits. OBJECTIVE: We evaluated the minimization of BH artifact with dual-energy (kVp) CT (DECT) generated monochromatic CT images to improve perfusion estimate's. METHODS: We investigated the performance of DECT with a scanner capable of rapid kVp switching with respect to (1) BH artifact in a myocardium phantom model comparing SECT with image-based DECT and projection-based DECT, (2) optimal imaging parameters for measuring iodine concentration at high contrast-to-noise ratio in a tissue characterization phantom model, and (3) the feasibility of a dynamic time-resolved scan protocol with the projection-based DECT technique to measure myocardial perfusion in normal (nonischemic) porcine. RESULTS: In a myocardium phantom model, projection-based DECT 70 keV was better able to minimize the difference in the attenuation of the myocardium (19.9 HU) between having and not having contrast in the heart chambers in comparison to SECT using 80 kVp (30.4 HU) or 140 kVp ( 23.3 HU) and image-based DECT 70 keV (27.5 HU). Further, projection-based DECT 70 keV achieved the highest contrast-to-noise ratio (3.0), which exceeded that from imaged-based DECT 70 keV (2.0), 140 kVp SECT (1.3), and 80 kVp SECT (2.9). In 5 normal pigs, projection-based DECT at 70 keV provided a more uniform perfusion estimate than SECT. CONCLUSION: By effectively reducing BH artifact, projection-based DECT may permit improved quantitative myocardial CTP compared with the conventional SECT technique. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:430 / 442
页数:13
相关论文
共 50 条
  • [1] Dual-Energy CT with Fast-KVp Switch
    Hsieh, J.
    MEDICAL PHYSICS, 2009, 36 (06) : 2749 - +
  • [2] Prospectively ECG-Triggered Rapid kV-Switching Dual-Energy CT for Quantitative Imaging of Myocardial Perfusion
    So, Aaron
    Hsieh, Jiang
    Imai, Yasuhiro
    Narayanan, Suresh
    Kramer, John
    Procknow, Karen
    Dutta, Sandeep
    Leipsic, Jonathon
    Min, James K.
    LaBounty, Troy
    Lee, Ting-Yim
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (08) : 829 - 836
  • [3] Dual-energy CT and its potential use for quantitative myocardial CT perfusion
    So, Aaron
    Hsieh, Jiang
    Narayanan, Suresh
    Thibault, Jean-Baptiste
    Imai, Yasuhiro
    Dutta, Sandeep
    Leipsic, Jonathon
    Min, James
    LaBounty, Troy
    Lee, Ting-Yim
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (05) : 308 - 317
  • [4] Quantitative evaluation of beam-hardening artefact correction in dual-energy CT myocardial perfusion imaging
    Andreas M. Bucher
    Julian L. Wichmann
    U. Joseph Schoepf
    Christopher D. Wolla
    Christian Canstein
    Andrew D. McQuiston
    Aleksander W. Krazinski
    Carlo N. De Cecco
    Felix G. Meinel
    Thomas J. Vogl
    Lucas L. Geyer
    European Radiology, 2016, 26 : 3215 - 3222
  • [5] Quantitative evaluation of beam-hardening artefact correction in dual-energy CT myocardial perfusion imaging
    Bucher, Andreas M.
    Wichmann, Julian L.
    Schoepf, U. Joseph
    Wolla, Christopher D.
    Canstein, Christian
    McQuiston, Andrew D.
    Krazinski, Aleksander W.
    De Cecco, Carlo N.
    Meinel, Felix G.
    Vogl, Thomas J.
    Geyer, Lucas L.
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 3215 - 3222
  • [6] Motion Correction for Improving the Accuracy of Dual-Energy Myocardial Perfusion CT Imaging
    Pack, Jed D.
    Yin, Zhye
    Xiong, Guanglei
    Mittal, Priya
    Dunham, Simon
    Elmore, Kimberly
    Edic, Peter M.
    Min, James K.
    MEDICAL IMAGING 2016-BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2016, 9788
  • [7] Dual-energy CT lung perfusion in systemic sclerosis: preliminary experience in 101 patients
    Dupont, Antoine
    Koether, Vincent
    Labreuche, Julien
    Felloni, Paul
    Perez, Thierry
    de Groote, Pascal
    Remy, Jacques
    Duhamel, Alain
    Hachulla, Eric
    Launay, David
    Remy-Jardin, Martine
    EUROPEAN RADIOLOGY, 2023, 33 (01) : 401 - 413
  • [8] Dual-energy CT lung perfusion in systemic sclerosis: preliminary experience in 101 patients
    Antoine Dupont
    Vincent Koether
    Julien Labreuche
    Paul Felloni
    Thierry Perez
    Pascal de Groote
    Jacques Remy
    Alain Duhamel
    Eric Hachulla
    David Launay
    Martine Remy-Jardin
    European Radiology, 2023, 33 : 401 - 413
  • [9] Pulmonary ventilation and perfusion imaging with dual-energy CT
    Sven F. Thieme
    Sandra Hoegl
    Konstantin Nikolaou
    Juergen Fisahn
    Michael Irlbeck
    Daniel Maxien
    Maximilian F. Reiser
    Christoph R. Becker
    Thorsten R. C. Johnson
    European Radiology, 2010, 20 : 2882 - 2889
  • [10] Pulmonary ventilation and perfusion imaging with dual-energy CT
    Thieme, Sven F.
    Hoegl, Sandra
    Nikolaou, Konstantin
    Fisahn, Juergen
    Irlbeck, Michael
    Maxien, Daniel
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    EUROPEAN RADIOLOGY, 2010, 20 (12) : 2882 - 2889