Quantitative myocardial perfusion imaging using rapid kVp switch dual-energy CT: Preliminary experience

被引:49
|
作者
So, Aaron [1 ,2 ]
Lee, Ting-Yim [1 ,2 ]
Imai, Yasuhiro [3 ]
Narayanan, Suresh [3 ]
Hsieh, Jiang [3 ]
Kramer, John [3 ]
Procknow, Karen [3 ]
Leipsic, Jonathon [4 ]
LaBounty, Troy [5 ]
Min, James
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Lawson Hlth Res Inst, London, ON, Canada
[3] GE Healthcare, CT Engn, Waukesha, WI USA
[4] St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
[5] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
基金
加拿大健康研究院;
关键词
Quantitative myocardial CT perfusion; Beam-hardening artifact; Beam-hardening correction; Single-energy CT; Dual-energy CT; CONVENTIONAL CORONARY-ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; STRESS; ISCHEMIA; EXTENT; SPECT; HEART; REST;
D O I
10.1016/j.jcct.2011.10.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Quantitative myocardial CT perfusion (CTP) is susceptible to beam-hardening (BH) artifact from conventional single-energy (kVp) CT (SECT) scanning, which can mimic perfusion deficits. OBJECTIVE: We evaluated the minimization of BH artifact with dual-energy (kVp) CT (DECT) generated monochromatic CT images to improve perfusion estimate's. METHODS: We investigated the performance of DECT with a scanner capable of rapid kVp switching with respect to (1) BH artifact in a myocardium phantom model comparing SECT with image-based DECT and projection-based DECT, (2) optimal imaging parameters for measuring iodine concentration at high contrast-to-noise ratio in a tissue characterization phantom model, and (3) the feasibility of a dynamic time-resolved scan protocol with the projection-based DECT technique to measure myocardial perfusion in normal (nonischemic) porcine. RESULTS: In a myocardium phantom model, projection-based DECT 70 keV was better able to minimize the difference in the attenuation of the myocardium (19.9 HU) between having and not having contrast in the heart chambers in comparison to SECT using 80 kVp (30.4 HU) or 140 kVp ( 23.3 HU) and image-based DECT 70 keV (27.5 HU). Further, projection-based DECT 70 keV achieved the highest contrast-to-noise ratio (3.0), which exceeded that from imaged-based DECT 70 keV (2.0), 140 kVp SECT (1.3), and 80 kVp SECT (2.9). In 5 normal pigs, projection-based DECT at 70 keV provided a more uniform perfusion estimate than SECT. CONCLUSION: By effectively reducing BH artifact, projection-based DECT may permit improved quantitative myocardial CTP compared with the conventional SECT technique. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:430 / 442
页数:13
相关论文
共 50 条
  • [41] Dual-energy CT lung ventilation/perfusion imaging for diagnosing pulmonary embolism
    Long Jiang Zhang
    Chang Sheng Zhou
    U. Joseph Schoepf
    Hui Xue Sheng
    Sheng Yong Wu
    Aleksander W. Krazinski
    Justin R. Silverman
    Felix G. Meinel
    Yan E. Zhao
    Zong Jun Zhang
    Guang Ming Lu
    European Radiology, 2013, 23 : 2666 - 2675
  • [42] Dual-energy CT lung ventilation/perfusion imaging for diagnosing pulmonary embolism
    Zhang, Long Jiang
    Zhou, Chang Sheng
    Schoepf, U. Joseph
    Sheng, Hui Xue
    Wu, Sheng Yong
    Krazinski, Aleksander W.
    Silverman, Justin R.
    Meinel, Felix G.
    Zhao, Yan E.
    Zhang, Zong Jun
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2013, 23 (10) : 2666 - 2675
  • [43] Imaging of acute pulmonary embolism using a dual energy CT system with rapid kVp switching: Initial results
    Geyer, Lucas L.
    Scherr, Michael
    Koerner, Markus
    Wirth, Stefan
    Deak, Paul
    Reiser, Maximilian F.
    Linsenmaier, Ulrich
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 3711 - 3718
  • [44] Dual-Energy CT Perfusion During Pharmacologic Stress for the Assessment of Myocardial Perfusion Defects Using a Second-Generation Dual-Source CT: A Comparison With Cardiac Magnetic Resonance Imaging
    Kim, Sung Mok
    Chang, Sung-A
    Shin, Wonseon
    Choe, Yeon Hyeon
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) : 44 - 52
  • [45] Dual-energy CT and coronary imaging
    Kay, Fernando Uliana
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2020, 10 (04) : 1090 - 1107
  • [46] Imaging the Spine with Dual-Energy CT
    Murray N.
    Le M.
    Ebrahimzadeh O.
    Alharthy A.
    Mohammed M.F.
    Ouellette H.A.
    Khosa F.
    Current Radiology Reports, 5 (9)
  • [47] Dual-Energy CT in Oncologic Imaging
    Foti, Giovanni
    Ascenti, Giorgio
    Agostini, Andrea
    Longo, Chiara
    Lombardo, Fabio
    Inno, Alessandro
    Modena, Alessandra
    Gori, Stefania
    TOMOGRAPHY, 2024, 10 (03) : 299 - 319
  • [48] Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms
    Izuru Matsuda
    Masaaki Akahane
    Jiro Sato
    Masaki Katsura
    Shigeru Kiryu
    Naoki Yoshioka
    Akira Kunimatsu
    Kenji Ino
    Kuni Ohtomo
    Japanese Journal of Radiology, 2012, 30 : 34 - 39
  • [49] Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms
    Matsuda, Izuru
    Akahane, Masaaki
    Sato, Jiro
    Katsura, Masaki
    Kiryu, Shigeru
    Yoshioka, Naoki
    Kunimatsu, Akira
    Ino, Kenji
    Ohtomo, Kuni
    JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (01) : 34 - 39
  • [50] Comparison of low kVp CT and dual-energy CT for the evaluation of hypervascular hepatocellular carcinoma
    Yoo, Jeongin
    Lee, Jeong Min
    Yoon, Jeong Hee
    Joo, Ijin
    Lee, Eun Sun
    Jeon, Sun Kyung
    Jang, Siwon
    ABDOMINAL RADIOLOGY, 2021, 46 (07) : 3217 - 3226