Quantitative myocardial perfusion imaging using rapid kVp switch dual-energy CT: Preliminary experience

被引:49
|
作者
So, Aaron [1 ,2 ]
Lee, Ting-Yim [1 ,2 ]
Imai, Yasuhiro [3 ]
Narayanan, Suresh [3 ]
Hsieh, Jiang [3 ]
Kramer, John [3 ]
Procknow, Karen [3 ]
Leipsic, Jonathon [4 ]
LaBounty, Troy [5 ]
Min, James
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Lawson Hlth Res Inst, London, ON, Canada
[3] GE Healthcare, CT Engn, Waukesha, WI USA
[4] St Pauls Hosp, Vancouver, BC V6Z 1Y6, Canada
[5] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
基金
加拿大健康研究院;
关键词
Quantitative myocardial CT perfusion; Beam-hardening artifact; Beam-hardening correction; Single-energy CT; Dual-energy CT; CONVENTIONAL CORONARY-ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; STRESS; ISCHEMIA; EXTENT; SPECT; HEART; REST;
D O I
10.1016/j.jcct.2011.10.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Quantitative myocardial CT perfusion (CTP) is susceptible to beam-hardening (BH) artifact from conventional single-energy (kVp) CT (SECT) scanning, which can mimic perfusion deficits. OBJECTIVE: We evaluated the minimization of BH artifact with dual-energy (kVp) CT (DECT) generated monochromatic CT images to improve perfusion estimate's. METHODS: We investigated the performance of DECT with a scanner capable of rapid kVp switching with respect to (1) BH artifact in a myocardium phantom model comparing SECT with image-based DECT and projection-based DECT, (2) optimal imaging parameters for measuring iodine concentration at high contrast-to-noise ratio in a tissue characterization phantom model, and (3) the feasibility of a dynamic time-resolved scan protocol with the projection-based DECT technique to measure myocardial perfusion in normal (nonischemic) porcine. RESULTS: In a myocardium phantom model, projection-based DECT 70 keV was better able to minimize the difference in the attenuation of the myocardium (19.9 HU) between having and not having contrast in the heart chambers in comparison to SECT using 80 kVp (30.4 HU) or 140 kVp ( 23.3 HU) and image-based DECT 70 keV (27.5 HU). Further, projection-based DECT 70 keV achieved the highest contrast-to-noise ratio (3.0), which exceeded that from imaged-based DECT 70 keV (2.0), 140 kVp SECT (1.3), and 80 kVp SECT (2.9). In 5 normal pigs, projection-based DECT at 70 keV provided a more uniform perfusion estimate than SECT. CONCLUSION: By effectively reducing BH artifact, projection-based DECT may permit improved quantitative myocardial CTP compared with the conventional SECT technique. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:430 / 442
页数:13
相关论文
共 50 条
  • [21] Initial experience of dual-energy lung perfusion CT using a dual-source CT system in children
    Hyun Woo Goo
    Pediatric Radiology, 2010, 40 : 1536 - 1544
  • [22] QUANTITATIVE MYOCARDIAL CT PERFUSION WITH RAPID KV SWITCHING DUAL ENERGY CT: A MICROSPHERES VALIDATION STUDY
    So, Aaron
    Hsieh, Jiang
    Imai, Yashirho
    Narayanan, Suresh
    Thibault, Jean-Baptiste
    Dutta, Sandeep
    Branch, Kelley
    Lee, Ting-Yim
    HEART, 2013, 99 : E269 - E270
  • [23] Quantitative myocardial CT perfusion with rapid kV switching dual energy CT: a microspheres validation study
    So, Aaron
    Hsieh, Jiang
    Imai, Yashirho
    Narayanan, Suresh
    Thibault, Jean-Baptiste
    Dutta, Sandeep
    Branch, Kelley
    Lee, Ting-Yim
    CARDIOLOGY, 2013, 126 : 86 - 87
  • [24] Diagnostic accuracy of coronary CT angiography combined with dual-energy myocardial perfusion imaging for detection of myocardial infarction
    Han, Ruijuan
    Sun, Kai
    Lu, Bin
    Zhao, Ruiping
    Li, Kuncheng
    Yang, Xinchun
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (01) : 207 - 213
  • [25] Improved imaging of colorectal liver metastases using single-source, fast kVp-switching, dual-energy CT: preliminary results
    Ratajczak, Przemyslaw
    Serafin, Zbigniew
    Slawinska, Agata
    Slupski, Maciej
    Leszczynski, Waldemar
    POLISH JOURNAL OF RADIOLOGY, 2018, 83 : E514 - E520
  • [26] Diagnostic Performance of Dual-Energy CT Stress Myocardial Perfusion Imaging: Direct Comparison With Cardiovascular MRI
    Ko, Sung Min
    Song, Meong Gun
    Chee, Hyun Kun
    Hwang, Hweung Kon
    Feuchtner, Gudrun Maria
    Min, James K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (06) : W605 - W613
  • [27] Normalized Dual-Energy Iodine Ratio Best Differentiates Renal Cell Carcinoma Subtypes Among Quantitative Imaging Biomarkers From Perfusion CT and Dual-Energy CT
    Manoharan, Dinesh
    Netaji, Arjunlokesh
    Diwan, Kanika
    Sharma, Sanjay
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (06) : 1389 - 1397
  • [28] OPTIMIZED KVP, FILTRATION AND DETECTION PARAMETERS FOR DUAL-ENERGY IMAGING
    RUTT, BK
    MEDICAL PHYSICS, 1985, 12 (04) : 536 - 536
  • [29] Dual-Energy Perfusion-CT in Recurrent Pancreatic Cancer - Preliminary Results
    Fritz, F.
    Skornitzke, S.
    Hackert, T.
    Kauczor, H. U.
    Stiller, W.
    Grenacher, L.
    Klauss, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (06): : 559 - 565
  • [30] Comparative diagnostic accuracy of dual-energy CT myocardial perfusion imaging by monochromatic energy versus material decomposition methods
    Danad, Ibrahim
    Cho, Iksung
    Elmore, Kimberly
    Schulman-Marcus, Joshua
    Hartaigh, Briain O.
    Stuijfzand, Wijnand J.
    Carrascosa, Patricia
    Min, James K.
    CLINICAL IMAGING, 2018, 50 : 1 - 4