GDL-FIRE4D: Deep Learning-Based Fast 4D CT Image Registration

被引:35
|
作者
Sentker, Thilo [1 ,2 ]
Madesta, Frederic [1 ,2 ]
Werner, Rene [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Computat Neurosci, Martinistr 52, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Radiotherapy & Radiat Oncol, Martinistr 52, D-20246 Hamburg, Germany
来源
MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT I | 2018年 / 11070卷
关键词
Non-linear image registration; Registration uncertainty; 4D CT; Deep learning;
D O I
10.1007/978-3-030-00928-1_86
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Deformable image registration (DIR) in thoracic 4D CT image data is integral for, e.g., radiotherapy treatment planning, but time consuming. Deep learning (DL)-based DIR promises speed-up, but present solutions are limited to small image sizes. In this paper, we propose a General Deep Learning-based Fast Image Registration framework suitable for application to clinical 4D CT data (GDL-FIRE4D). Open source DIR frameworks are selected to build GDL-FIRE4D variants. In-house-acquired 4D CT images serve as training and open(4D) CT data repositories as external evaluation cohorts. Taking up current attempts to DIR uncertainty estimation, dropout-based uncertainty maps for GDL-FIRE4D variants are analyzed. We show that (1) registration accuracy of GDL-FIRE4D and standard DIR are in the same order; (2) computation time is reduced to a few seconds (here: 60-fold speed-up); and (3) dropout-based uncertainty maps do not correlate to across-DIR vector field differences, raising doubts about applicability in the given context.
引用
收藏
页码:765 / 773
页数:9
相关论文
共 50 条
  • [41] Deep learning-based 3D brain multimodal medical image registration
    Deng, Liwei
    Lan, Qi
    Zhi, Qiang
    Huang, Sijuan
    Wang, Jing
    Yang, Xin
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (02) : 505 - 519
  • [42] Consistent estimation of cardiac motions by 4D image registration
    Shen, DG
    Sundar, H
    Xue, Z
    Fan, Y
    Litt, H
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 902 - 910
  • [43] Multimodality and 4D image registration: Methods and clinical use
    Kessler, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2618 - 2618
  • [44] Feature-aligned 4D Spatiotemporal Image Registration
    Xu, Huanhuan
    Chen, Peizhi
    Yu, Wuyi
    Sawant, Amit
    Iyengar, S. S.
    Li, Xin
    2012 21ST INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR 2012), 2012, : 2639 - 2642
  • [45] Validation of a GPU-Based Fast Deformable Image Registration Platform for 4D Treatment Planning Application
    Roland, Teboh
    Hales, R.
    McNutt, T.
    Wong, J.
    Simari, P.
    Tryggestad, E.
    MEDICAL PHYSICS, 2011, 38 (06) : 3628 - +
  • [46] Clinical application of breathing-adapted 4D CT: image quality comparison to conventional 4D CT
    Werner, Rene
    Szkitsak, Juliane
    Madesta, Frederic
    Buettgen, Laura
    Wimmert, Lukas
    Sentker, Thilo
    Fietkau, Rainer
    Haderlein, Marlen
    Bert, Christoph
    Gauer, Tobias
    Hofmann, Christian
    STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 (07) : 686 - 691
  • [47] Clinical application of breathing-adapted 4D CT: image quality comparison to conventional 4D CT
    René Werner
    Juliane Szkitsak
    Frederic Madesta
    Laura Büttgen
    Lukas Wimmert
    Thilo Sentker
    Rainer Fietkau
    Marlen Haderlein
    Christoph Bert
    Tobias Gauer
    Christian Hofmann
    Strahlentherapie und Onkologie, 2023, 199 : 686 - 691
  • [48] 4D CT Image Based Bifurcation Trajectory Tracking in the Lung
    Xiong, G.
    Xing, L.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [49] Segmentation of cardiac MR and CT image sequences using model based registration of a 4D statistical model
    Perperidis, Dimitrios
    Mohiaddin, Raad
    Edwards, Philip
    Rueckert, Daniel
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [50] Reduce Artifacts for Helical 4D CT Image
    Han, D.
    Bayouth, J.
    Bhatia, S.
    Sonka, M.
    Wu, X.
    MEDICAL PHYSICS, 2010, 37 (06) : 3126 - +