Detection of anti-dsDNA antibodies by computer-aided automated immunofluorescence analysis

被引:12
|
作者
Lakos, Gabriella [1 ]
Gonzalez, Marlene [1 ]
Flaherty, David [1 ]
Bentow, Chelsea [1 ]
Ibarra, Claudia [2 ]
Stimson, Deborah [2 ]
Nacario, Lori [2 ]
Hiemann, Rico [3 ]
Dervieux, Thierry [2 ]
机构
[1] Inova Diagnost Inc, San Diego, CA 92182 USA
[2] Exagen Diagnost, Vista, CA USA
[3] Brandenburg Univ Technol Cottbus Senftenberg, Fac Nat Sci, Senftenberg, Germany
关键词
dsDNA; Autoantibodies; Indirect immunofluorescence; Systemic lupus erythematosus; Crithidia luciliae; DOUBLE-STRANDED DNA; CRITHIDIA-LUCILIAE; CLASSIFICATION; ASSAYS; FARR;
D O I
10.1016/j.jim.2016.02.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Introduction: NOVA View is a computer aided fluorescence microscope that is used for the automated reading and interpretation of indirect immunofluorescent tests in diagnostic immunology. The objective of the present study was to evaluate the performance of the NOVA View system for the measurement of anti-dsDNA antibodies using the Crithidia luciliae indirect immunofluorescence test (CLIFT) technology. Methods: Analytical performance of NOVA View CLIFF was assessed in repeatability (within run) and reproducibility (between runs and instruments) studies. Two hundred-fifty patient samples (N = 200 consecutive samples and N = 50 samples from systemic lupus erythematosus patients) were tested to evaluate the agreement between results generated with NOVA View CLIFF, and those obtained with manual microscopic reading of the same slides. Positivity rate in SLE was assessed on the 50 SLE samples. Results: The NOVA View system showed high level of repeatability and reproducibility within runs, between runs, and between instruments. Agreement of NOVA View software interpretation and digital image reading results with manual microscopic reading results was 96.0%, and the same positivity rate was obtained on SLE samples by NOVA View digital image reading as that of manual microscopic reading (36.0% vs. 38.0%, respectively). Conclusion: Results generated by NOVA View CLIFF were equivalent to those obtained by manual microscopic reading on a large routine sample set. NOVA View demonstrated consistency within and between runs, and between instruments. Automation of CLIFF provides reliability and is a suitable alternative for routine clinical laboratories. (C) 2016 The Authors. Published by Elsevier B.V.
引用
收藏
页码:17 / 22
页数:6
相关论文
共 50 条
  • [41] A peptide DNA surrogate that binds and inhibits anti-dsDNA antibodies
    Zhang, W
    Reichlin, M
    CLINICAL IMMUNOLOGY, 2005, 117 (03) : 214 - 220
  • [42] The role of positive feedback loops involving anti-dsDNA and anti-anti-dsDNA antibodies in autoimmune glomerulonephritis
    Arazi, A.
    Neumann, A. U.
    JOURNAL OF THEORETICAL BIOLOGY, 2013, 319 : 8 - 22
  • [43] INCIDENCE OF ANTI-DSDNA ANTIBODIES IN ANA-POSITIVE SERA
    DEEGAN, MJ
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1981, 75 (06) : 873 - 873
  • [44] Studies on the structure, regulation, and pathogenic potential of Anti-dsDNA antibodies
    Spatz, L
    Iliev, A
    Saenko, V
    Jones, L
    Irigoyen, M
    ManheimerLory, A
    Gaynor, B
    Putterman, C
    Bynoe, M
    Kowal, C
    Kuo, P
    Newman, J
    Diamond, B
    METHODS, 1997, 11 (01) : 70 - 78
  • [45] ANTIGEN SPECIFIC INDUCTION OF ANTI-DSDNA ANTIBODIES IN NONAUTOIMMUNE MICE
    DESAI, DD
    KRISHNAN, M
    MARION, TN
    FASEB JOURNAL, 1992, 6 (05): : A1795 - A1795
  • [46] Usefulness of anti-dsDNA antibody screening with chemiluminescence followed by confirmation by indirect immunofluorescence
    Monteiro Callado, Maria Roseli
    Costa Lima, Jose Rubens
    de Alencar Barroso, Maria Nancy
    Mota Pinheiro, Antonio Tiago
    da Cruz Neto, Moises Francisco
    de Lima Abreu, Maria Arenilda
    Vieira, Walber Pinto
    REVISTA BRASILEIRA DE REUMATOLOGIA, 2013, 53 (05) : 412 - 418
  • [47] IDIOTYPIC INDEPENDENCE OF ANTI-DSDNA AND ANTI-SM ANTIBODIES IN SLE SERA
    KUBOTA, T
    DANG, H
    TAKEI, M
    MIYASAKA, N
    KANAI, Y
    TALAL, N
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 1989, 7 (05) : 572 - 573
  • [48] Computer-aided detection and automated CT volumetry of pulmonary nodules
    Katharina Marten
    Christoph Engelke
    European Radiology, 2007, 17 : 888 - 901
  • [49] Computer-aided detection and automated CT volumetry of pulmonary nodules
    Marten, Katharina
    Engelke, Christoph
    EUROPEAN RADIOLOGY, 2007, 17 (04) : 888 - 901
  • [50] Diagnostic sensitivity and specificity of the farrzyme immunoassay for the detection of anti-dsDNA antibodies, an Italian multicenter study
    Budd, R.
    Ghirardello, A.
    Doria, A.
    Villalta, D.
    Morozzi, G.
    Meroni, P. L.
    Tincani, A.
    Bradwell, A. R.