Analytical evaluation of direct bicarbonate measurement with the new gem premier chemstat in hemodialysis patients

被引:0
|
作者
Balboni, Fiamma [1 ]
Terreni, Alessandro [2 ]
Gallo, Marco [3 ]
Guzzi, Francesco [3 ]
Caparrini, Chiara [4 ]
Burbui, Stefania [5 ]
Vezzosi, Marco [1 ]
Galora, Silvia [1 ]
Lori, Giulia [1 ]
Lippi, Giuseppe [6 ]
机构
[1] Ist Fiorentino Cura & Assistenza IFCA, Lab Serv, Florence, Italy
[2] SOD Sicurezza & Qualita Careggi Hosp, Florence, Italy
[3] IFCA, UO Nefrol & Dialisi Ist Fiorentino Cura & Assiste, Florence, Italy
[4] IFCA, UO Anestesia & Rianimaz Ist Fiorentino Cura & Ass, Florence, Italy
[5] IFCA, Outpatients Serv, Florence, Italy
[6] Univ Verona, Sect Clin Biochem, Verona, Italy
关键词
Performance; measure error; bed-side analysis; potentiometry; SERUM BICARBONATE; METABOLIC-ACIDOSIS; RISK; ASSOCIATION; MORTALITY;
D O I
10.1080/00365513.2021.1930142
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
GEM Premier ChemSTAT is a whole-blood analyzer designed for providing a rapid basic metabolic panel, inclusive of creatinine and blood urea nitrogen, with the unique characteristic of providing measured bicarbonate (HCO3-) levels. The aim of this work was to evaluate the clinical performance of HCO3- assessment with this analyser in a real-life hemodialysis setting. Imprecision was calculated at different HCO3- levels, along with assay comparison with Gem Premier 4000 analysers. GEM Premier ChemSTAT displayed an imprecision and a bias (in comparison to GEM Premier 4000) for HCO3- of 0.4% and 37.3% at 20.8 mmol/L, 1.2% and 25.6% at 16.4 mmol/L, and 2.1% and 11.6% at 11.5 mmol/L, respectively, using three levels of HCO3- quality control sample ChemSTAT System Evaluator. At direct comparison with the GEM Premier 4000 in the hemodialysis setting, Bland-Altman analysis of HCO3- levels evidenced a bias (mu) of -4.9 (95% CI, -5.2 to -4.7) mmol/L. Such difference was attenuated by recalculating the GEM ChemSTAT expected HCO3- values from pH and pCO(2) using the Henderson Hasselbach equation, mu=-0.07 (95%CI, -0.19 to 0.05) mmol/L (p = .24). In conclusion, our results show a remarkable difference between the HCO3- values reported by GEM ChemSTAT or GEM 4000. New reference values for GEM ChemSTAT HCO3- shall hence be defined according to our findings. We suggest that further investigation and a re-evaluation of the reference range should be made before extending the clinical use of this device.
引用
收藏
页码:418 / 421
页数:4
相关论文
共 50 条
  • [31] A critical evaluation of ultrasound measurement of inferior vena cava diameter in assessing dry weight in normotensive and hypertensive hemodialysis patients
    Katzarski, KS
    Nisell, J
    Randmaa, I
    Danielsson, A
    Freyschuss, U
    Bergstrom, J
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 30 (04) : 459 - 465
  • [32] Analytical and clinical evaluation of the new TOSOH G8 analyser for HbA1c measurement
    Teixeira, J.
    Aldenhoff, M. -C.
    Chapelle, J. -P.
    ACTA CLINICA BELGICA, 2007, 62 (06): : 461 - 461
  • [33] New Approaches to the Evaluation of Coronary Endothelial Function - Direct Measurement of Intra-Arterial NO Concentration In Vivo
    Hamasaki, Shuichi
    Tei, Chuwa
    CIRCULATION JOURNAL, 2009, 73 (03) : 434 - 435
  • [34] SERUM FERRITIN - NEW PARAMETER FOR EVALUATION OF BODY IRON STORAGE IN PATIENTS ON HEMODIALYSIS OR WITH KIDNEY-TRANSPLANTS
    KOHN, H
    WIDER, G
    ZAZGORNIK, J
    ZIMMERMANN, E
    BAYER, PM
    MOSTBECK, A
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1979, 17 (03): : 171 - 171
  • [35] A NEW INSIGHT INTO THE MECHANISM OF ATHEROSCLEROSIS IN HEMODIALYSIS PATIENTS THROUGH THE EVALUATION OF SCAVENGER RECEPTOR EXPRESSIONS IN PERIPHERAL MONOCYTE
    Nishida, Miki
    Ando, Minoru
    Karasawa, Kazunori
    Iwamoto, Yusuke
    Tsuchiya, Ken
    Nitta, Kosaku
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2014, 29 : 234 - 234
  • [36] Analytical performance evaluation of an assay for the direct measurement of HbA1c in whole blood on RX series analysers of different throughput
    Mcgivern, P.
    Donnelly, E.
    Sheehy, N.
    Rodriguez, M.
    Lenehan, E.
    Fitzgerald, S.
    CLINICA CHIMICA ACTA, 2019, 493 : S290 - S291
  • [37] CLINICAL AND ANALYTICAL EVALUATION OF 2 IMMUNOASSAYS FOR DIRECT MEASUREMENT OF CREATINE-KINASE MB WITH MONOCLONAL ANTI-CK-MB ANTIBODIES
    APPLE, F
    PREESE, L
    BENNETT, R
    FREDRICKSON, A
    CLINICAL CHEMISTRY, 1988, 34 (11) : 2364 - 2367
  • [38] Evaluation of the analytical performance of a new ADVIA immunoassay using the Centaur XPT platform system for the measurement of cardiac troponin I
    Musetti, Veronica
    Masotti, Silvia
    Prontera, Concetta
    Storti, Simona
    Ndreu, Rudina
    Zucchelli, Gian Carlo
    Passino, Claudio
    Emdin, Michele
    Clerico, Aldo
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (09) : E229 - E231
  • [39] DOSE EVALUATION TO PATIENTS IRRADIATED BY CO-60 BEAMS, BY MEANS OF DIRECT MEASUREMENT ON THE INCIDENT AND ON THE EXIT SURFACES
    RIZZOTTI, A
    COMPRI, C
    GARUSI, GF
    RADIOTHERAPY AND ONCOLOGY, 1985, 3 (03) : 279 - 283
  • [40] Evaluation of the new Abbott®Alinity assay for the measurement of thyroglobulin antibodies in patients with differentiated thyroid carcinoma
    Cano, Ana M. Garcia
    Coronado, Marta Rosillo
    Garcia, Laura Alcazar
    Lozano, Ana Gomez
    Sayalero, Angela Carrasco
    Torres, Argeme Rodriguez
    ANNALS OF CLINICAL BIOCHEMISTRY, 2023, 60 (02) : 136 - 141