Analytical evaluation of direct bicarbonate measurement with the new gem premier chemstat in hemodialysis patients

被引:0
|
作者
Balboni, Fiamma [1 ]
Terreni, Alessandro [2 ]
Gallo, Marco [3 ]
Guzzi, Francesco [3 ]
Caparrini, Chiara [4 ]
Burbui, Stefania [5 ]
Vezzosi, Marco [1 ]
Galora, Silvia [1 ]
Lori, Giulia [1 ]
Lippi, Giuseppe [6 ]
机构
[1] Ist Fiorentino Cura & Assistenza IFCA, Lab Serv, Florence, Italy
[2] SOD Sicurezza & Qualita Careggi Hosp, Florence, Italy
[3] IFCA, UO Nefrol & Dialisi Ist Fiorentino Cura & Assiste, Florence, Italy
[4] IFCA, UO Anestesia & Rianimaz Ist Fiorentino Cura & Ass, Florence, Italy
[5] IFCA, Outpatients Serv, Florence, Italy
[6] Univ Verona, Sect Clin Biochem, Verona, Italy
关键词
Performance; measure error; bed-side analysis; potentiometry; SERUM BICARBONATE; METABOLIC-ACIDOSIS; RISK; ASSOCIATION; MORTALITY;
D O I
10.1080/00365513.2021.1930142
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
GEM Premier ChemSTAT is a whole-blood analyzer designed for providing a rapid basic metabolic panel, inclusive of creatinine and blood urea nitrogen, with the unique characteristic of providing measured bicarbonate (HCO3-) levels. The aim of this work was to evaluate the clinical performance of HCO3- assessment with this analyser in a real-life hemodialysis setting. Imprecision was calculated at different HCO3- levels, along with assay comparison with Gem Premier 4000 analysers. GEM Premier ChemSTAT displayed an imprecision and a bias (in comparison to GEM Premier 4000) for HCO3- of 0.4% and 37.3% at 20.8 mmol/L, 1.2% and 25.6% at 16.4 mmol/L, and 2.1% and 11.6% at 11.5 mmol/L, respectively, using three levels of HCO3- quality control sample ChemSTAT System Evaluator. At direct comparison with the GEM Premier 4000 in the hemodialysis setting, Bland-Altman analysis of HCO3- levels evidenced a bias (mu) of -4.9 (95% CI, -5.2 to -4.7) mmol/L. Such difference was attenuated by recalculating the GEM ChemSTAT expected HCO3- values from pH and pCO(2) using the Henderson Hasselbach equation, mu=-0.07 (95%CI, -0.19 to 0.05) mmol/L (p = .24). In conclusion, our results show a remarkable difference between the HCO3- values reported by GEM ChemSTAT or GEM 4000. New reference values for GEM ChemSTAT HCO3- shall hence be defined according to our findings. We suggest that further investigation and a re-evaluation of the reference range should be made before extending the clinical use of this device.
引用
收藏
页码:418 / 421
页数:4
相关论文
共 50 条
  • [21] Spiral computed tomographic angiography - A new technique for evaluation of vascular access in hemodialysis patients
    Lin, YP
    Wu, MH
    Ng, YY
    Lee, RC
    Liou, JK
    Yang, WC
    Wang, JH
    Teng, MMH
    Huang, TP
    AMERICAN JOURNAL OF NEPHROLOGY, 1998, 18 (02) : 117 - 122
  • [22] Evaluation of Heat Flux Measurement as a New Process Analytical Technology Monitoring Tool in Freeze Drying
    Vollrath, Ilona
    Pauli, Victoria
    Friess, Wolfgang
    Freitag, Angelika
    Hawe, Andrea
    Winter, Gerhard
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 106 (05) : 1249 - 1257
  • [23] New cell for measurement of liquid-liquid equilibria and solid-liquid equilibria by direct analytical methods
    Rehák, K
    CHEMICKE LISTY, 1999, 93 (09): : 583 - 585
  • [24] Measurement of intraoperative hemoglobin in pediatric orthopedic patients: evaluation of a new method
    Nowicki, P.
    Ndika, A.
    Kemppainen, J.
    Cassidy, J.
    Forness, M.
    Satish, S.
    Hassan, N.
    ANESTHESIA AND ANALGESIA, 2016, 123 : 4 - 5
  • [25] EVALUATION OF THYROID-FUNCTION BY RADIOIMMUNOLOGICAL MEASUREMENT OF FREE-THYROXINE IN PATIENTS UNDERGOING CHRONIC-HEMODIALYSIS
    KRAFT, D
    BUBER, V
    ARTIFICIAL ORGANS, 1980, 4 (02) : 143 - 143
  • [26] A New Method for the Measurement of International Normalized Ratio in Hemodialysis Patients with Heparin-Locked Tunneled Dialysis Catheters
    Seghers, Celine B.
    Ver Elst, Kristien
    Claessens, Jolien
    Weekx, Steven
    Vermeiren, Sigrid
    Henckes, Manu
    INTERNATIONAL JOURNAL OF NEPHROLOGY, 2020, 2020
  • [27] A NEW METHOD FOR THE MEASUREMENT OF INTERNATIONAL NORMALIZED RATIO IN HEMODIALYSIS PATIENTS WITH HEPARIN-LOCKED TUNNELED DIALYSIS CATHETERS
    Seghers, Celine B.
    Ver Elst, Kristien
    Claessens, Jolien
    Henckes, Manu
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34
  • [28] Evaluation of a new assay for the measurement of thyreoglobulin in patients affected by differentiated thyroid carcinoma
    Aliberti, G
    Ferrari, L
    Seregni, E
    Castellani, MR
    Maccauro, M
    Savelli, G
    Villano, C
    Oliviero, F
    Martinetti, A
    Bombardieri, E
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S399 - S399
  • [29] Measurement of Intraoperative Blood Loss in Pediatric Orthopaedic Patients: Evaluation of a New Method
    Nowicki, Philip D.
    Ndika, Akunne
    Kemppainen, John
    Cassidy, Jeffrey
    Forness, Michael
    Satish, Siddarth
    Hassan, Nabil
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS, 2018, 2 (05):
  • [30] An evaluation of 1-84 PTH measurement in relation to bone alkaline phosphatase and bone Gla protein in hemodialysis patients
    Miwa, N
    Nitta, K
    Kimata, N
    Watanabe, Y
    Suzuki, K
    Kawashima, A
    Haga, M
    Watanabe, R
    Aoki, T
    Akiba, T
    Nihei, H
    NEPHRON CLINICAL PRACTICE, 2003, 94 (02): : C29 - C32