Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy

被引:86
|
作者
Li, Tianfang [1 ]
Xing, Lei [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
image-guided radiotherapy; four-dimensional cone-beam CT; optimization;
D O I
10.1016/j.ijrobp.2006.10.024
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Four-dimensional cone-beam computed tomography (4D-CBCT) imaging is sensitive to parameters such as gantry rotation speed, number of gantry rotations, X-ray pulse rate, and tube current, as well as a patient's breathing pattern. The aim of this study is to optimize the image acquisition on a patient-specific basis while minimizing the scan time and the radiation dose. Methods and Materials: More than 60 sets of 4D-CBCT images, each with a temporal resolution of 10 phases, were acquired using multiple-gantry rotation and slow-gantry rotation techniques. The image quality was quantified with a relative root mean-square error (RE) and correlated with various acquisition settings; specitically, varying gantry rotation speed, varying both the rotation speed and the number of rotations, and varying both the rotation speed and tube current to keep the radiation exposure constant. These experiments were repeated for three different respiratory periods. Results: With similar radiation dose, 4D-CBCT images acquired with low current and low rotation speed have better quality over images obtained with high current and high rotation speed. In general, a one-rotation low-speed scan is superior to a two-rotation double-speed scan, even though they provide the same number of projections. Furthermore, it is found that the image quality behaves monotonically with the relative speed as defined by the gantry rotation speed and the patient respiratory period. Conclusions: The RE curves established in this work can be used to predict the 4D-CBCT image quality before a scan. This allows the acquisition protocol to be optimized individually to balance the desired quality with the associated scanning time and patient radiation dose. (c) 2007 Elsevier Inc.
引用
收藏
页码:1211 / 1219
页数:9
相关论文
共 50 条
  • [1] Individualizing 4D cone-beam CT (CBCT) acquisition protocol for external beam radiotherapy
    Mao, W.
    Li, T.
    Munro, P.
    Chao, M.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S146 - S147
  • [2] Actively triggered 4d cone-beam CT acquisition
    Fast, Martin F.
    Wisotzky, Eric
    Oelfke, Uwe
    Nill, Simeon
    MEDICAL PHYSICS, 2013, 40 (09)
  • [3] 4D Cone-Beam CT Acquisition Using Respiratory Phase Predication Technique
    Yan, P.
    Zhou, L.
    Li, Z.
    Chi, Y.
    Chang, J.
    Chao, C.
    MEDICAL PHYSICS, 2012, 39 (06) : 3602 - 3602
  • [4] Calypso 4D Localization and Cone-beam CT Evaluation of Cervical Motion during External Beam Radiotherapy for Intact Cervix Cancer
    Gatcombe, H. G.
    Liu, T.
    Chen, H.
    Godette, K. D.
    Diaz, R.
    Rossi, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S41 - S42
  • [5] Respiratory gated cone-beam CT volumetric imaging for external beam radiotherapy
    Moseley, DJ
    Hawkins, M
    Eccles, C
    Euler, C
    White, EA
    Bissonnette, J
    Dawson, LA
    Jaffray, DA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S27 - S28
  • [6] Iterative volume of interest based 4D cone-beam CT
    Martin, Rachael
    Ahmad, Moiz
    Hugo, Geoffrey
    Pan, Tinsu
    MEDICAL PHYSICS, 2017, 44 (12) : 6515 - 6528
  • [7] Optimization of a Linac-based 4D Cone-beam CT Acquisition Protocol for Image-guided Radiation Therapy
    Lu, J.
    Zheng, D.
    Weiss, E.
    Williamson, J.
    Keall, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S628 - S628
  • [8] Evaluation of gantry speed on image quality and imaging dose for 4D cone-beam CT acquisition
    Santoso, Andrew P.
    Song, Kwang H.
    Qin, Yujiao
    Gardner, Stephen J.
    Liu, Chang
    Chetty, Indrin J.
    Movsas, Benjamin
    Ajlouni, Munther
    Wen, Ning
    RADIATION ONCOLOGY, 2016, 11
  • [9] Evaluation of gantry speed on image quality and imaging dose for 4D cone-beam CT acquisition
    Andrew P. Santoso
    Kwang H. Song
    Yujiao Qin
    Stephen J. Gardner
    Chang Liu
    Indrin J. Chetty
    Benjamin Movsas
    Munther Ajlouni
    Ning Wen
    Radiation Oncology, 11
  • [10] Evaluation of Clinical Acceptability of DIR Mapped Contours for Adaptive Radiotherapy with 4D Cone-Beam CT
    Balik, S.
    Weiss, E.
    Jan, N.
    Zhang, L.
    Roman, N.
    Sleeman, W.
    Christensen, G.
    Williamson, J.
    Hugo, G.