Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy

被引:86
|
作者
Li, Tianfang [1 ]
Xing, Lei [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
image-guided radiotherapy; four-dimensional cone-beam CT; optimization;
D O I
10.1016/j.ijrobp.2006.10.024
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Four-dimensional cone-beam computed tomography (4D-CBCT) imaging is sensitive to parameters such as gantry rotation speed, number of gantry rotations, X-ray pulse rate, and tube current, as well as a patient's breathing pattern. The aim of this study is to optimize the image acquisition on a patient-specific basis while minimizing the scan time and the radiation dose. Methods and Materials: More than 60 sets of 4D-CBCT images, each with a temporal resolution of 10 phases, were acquired using multiple-gantry rotation and slow-gantry rotation techniques. The image quality was quantified with a relative root mean-square error (RE) and correlated with various acquisition settings; specitically, varying gantry rotation speed, varying both the rotation speed and the number of rotations, and varying both the rotation speed and tube current to keep the radiation exposure constant. These experiments were repeated for three different respiratory periods. Results: With similar radiation dose, 4D-CBCT images acquired with low current and low rotation speed have better quality over images obtained with high current and high rotation speed. In general, a one-rotation low-speed scan is superior to a two-rotation double-speed scan, even though they provide the same number of projections. Furthermore, it is found that the image quality behaves monotonically with the relative speed as defined by the gantry rotation speed and the patient respiratory period. Conclusions: The RE curves established in this work can be used to predict the 4D-CBCT image quality before a scan. This allows the acquisition protocol to be optimized individually to balance the desired quality with the associated scanning time and patient radiation dose. (c) 2007 Elsevier Inc.
引用
收藏
页码:1211 / 1219
页数:9
相关论文
共 50 条
  • [21] Dosimetric Evaluation of DIR Mapped Contours for Image Guided Adaptive Radiotherapy with 4D Cone-Beam CT
    Balik, S.
    Weiss, E.
    Jan, N.
    Zhang, L.
    Roman, N.
    Christensen, G.
    Williamson, J.
    Hugo, G.
    MEDICAL PHYSICS, 2014, 41 (06) : 191 - +
  • [22] Quantitative Assessment of 4D Cone-Beam CT Based Image Guidance for Patient Positioning in Precision Radiotherapy
    Gopal, A.
    Lee, S.
    Mittauer, K.
    Kahler, D.
    Lu, B.
    Samant, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3605 - 3605
  • [23] 4D Cone-Beam CT Ventilation Imaging to Facilitate Adaptive Functional Avoidance Lung Cancer Radiotherapy
    Kipritidis, J.
    Eslick, E.
    Cooper, B.
    O'Brien, R.
    Yamamoto, T.
    Williamson, J. F.
    Keall, P.
    JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (09) : S323 - S323
  • [24] Application of asymmetric cone-beam CT in radiotherapy
    Yu, LF
    Pelizzari, C
    Pan, XC
    Riem, H
    Munro, P
    Kaissl, W
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3249 - 3252
  • [25] ScatterNet for 4D cone-beam CT intensity correction of lung cancer patients
    Schmitz, H.
    Lombardo, E.
    Kawula, M.
    Parodi, K.
    Belka, C.
    Kamp, F.
    Kurz, C.
    Landry, G.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S785 - S786
  • [26] Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT
    Wang, Jing
    Gu, Xuejun
    MEDICAL PHYSICS, 2013, 40 (10)
  • [27] Evaluation of a 4D Cone-Beam CT Reconstruction Approach Using an Anthropomorphic Phantom
    Yaniv, Ziv
    Boese, Ian
    Sarmiento, Marily
    Cleary, Kevin
    INFORMATION PROCESSING IN COMPUTER-ASSISTED INTERVENTIONS, 2010, 6135 : 147 - +
  • [28] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-beam CT
    Wang, Jing
    Gu, Xuejun
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [29] Enhanced 4D cone-beam CT with inter-phase motion model
    Li, Tianfang
    Koong, Albert
    Xing, Lei
    MEDICAL PHYSICS, 2007, 34 (09) : 3688 - 3695
  • [30] Evaluation of a 4D Cone-Beam CT Reconstruction Approach using a Simulation Framework
    Hartl, Alexander
    Yaniv, Ziv
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5729 - 5732