Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy

被引:86
|
作者
Li, Tianfang [1 ]
Xing, Lei [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
image-guided radiotherapy; four-dimensional cone-beam CT; optimization;
D O I
10.1016/j.ijrobp.2006.10.024
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Four-dimensional cone-beam computed tomography (4D-CBCT) imaging is sensitive to parameters such as gantry rotation speed, number of gantry rotations, X-ray pulse rate, and tube current, as well as a patient's breathing pattern. The aim of this study is to optimize the image acquisition on a patient-specific basis while minimizing the scan time and the radiation dose. Methods and Materials: More than 60 sets of 4D-CBCT images, each with a temporal resolution of 10 phases, were acquired using multiple-gantry rotation and slow-gantry rotation techniques. The image quality was quantified with a relative root mean-square error (RE) and correlated with various acquisition settings; specitically, varying gantry rotation speed, varying both the rotation speed and the number of rotations, and varying both the rotation speed and tube current to keep the radiation exposure constant. These experiments were repeated for three different respiratory periods. Results: With similar radiation dose, 4D-CBCT images acquired with low current and low rotation speed have better quality over images obtained with high current and high rotation speed. In general, a one-rotation low-speed scan is superior to a two-rotation double-speed scan, even though they provide the same number of projections. Furthermore, it is found that the image quality behaves monotonically with the relative speed as defined by the gantry rotation speed and the patient respiratory period. Conclusions: The RE curves established in this work can be used to predict the 4D-CBCT image quality before a scan. This allows the acquisition protocol to be optimized individually to balance the desired quality with the associated scanning time and patient radiation dose. (c) 2007 Elsevier Inc.
引用
收藏
页码:1211 / 1219
页数:9
相关论文
共 50 条
  • [41] Thoracic 4D Cone-Beam CT Registration Incorporating a Fan-Beam CT-Derived Feasible Motion Descriptor
    Sang, Y.
    Ruan, D.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [42] CORRECTION STRATEGIES FOR CONE-BEAM CT GUIDED RADIOTHERAPY
    Remeijer, P.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S141 - S142
  • [43] Clinical implementation of cone-beam CT guided radiotherapy
    van Herk, M
    Jaffray, D
    Remeijer, P
    Sonke, JJ
    Lebesque, JV
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S17 - S17
  • [44] Optimizing image acquisition settings for cone-beam computed tomography in supine and prone breast radiotherapy
    De Puysseleyr, Annemieke
    Veldeman, Liv
    Bogaert, Evelien
    De Wagter, Carlos
    De Neve, Wilfried
    RADIOTHERAPY AND ONCOLOGY, 2011, 100 (02) : 227 - 230
  • [45] Motion-Compensated 4D Cone-Beam Computed Tomography
    Brehm, Marcus
    Berkus, Timo
    Oehlhafen, Markus
    Kunz, Patrik
    Kachelriess, Marc
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3986 - 3993
  • [46] Accuracy of 4D Cone Beam CT and 4D Fan Beam CT for Thoracic Radiation Therapy Simulation and Verification Imaging
    Nyflot, M.
    Bowen, S. R.
    Lee, T.
    Meyer, J.
    Sandison, G. A.
    Kinahan, P. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S640 - S640
  • [47] Sliding window cone-beam CT reconstruction for biopsy guidance in 4D CT fluoroscopy: A simulation study
    Grass, M
    Bontus, C
    Koehler, T
    Renisch, S
    Proksa, R
    RADIOLOGY, 2001, 221 : 424 - 424
  • [48] BEAM'S EYE VIEW BASED VERIFICATION OF ACTUAL DELIVERY USING IN-TREATMENT 4D CONE-BEAM CT
    Nakagawa, K.
    Haga, A.
    Yamashita, H.
    Kida, S.
    Saotome, N.
    Sakumi, A.
    Imae, T.
    Ohtomo, K.
    Masutani, Y.
    Yoda, K.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S438 - S438
  • [49] 3D and 4D imaging from multi-threaded cone-beam CT scans
    Knaup, Michael
    Kachelriess, Marc
    Kalender, Willi A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1881 - 1885
  • [50] Impact of baseline shifts on 4D cone-beam CT images using a 4D phantom driven by lung tumor motions
    Moriwaki, H.
    Shiraishi, K.
    Sakumi, A.
    Ikeda, T.
    Shimizu, W.
    Yoda, K.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S981 - S981