In vivo wear measurement in a modern total knee arthroplasty with model-based radiostereometric analysis

被引:9
|
作者
Gascone, T. [1 ,2 ,3 ]
Parashin, S. [1 ,4 ]
Teeter, M. [1 ,5 ]
Bohm, E. [1 ,3 ,4 ,6 ]
Laende, E. [1 ,7 ,8 ]
Dunbar, M. [1 ,7 ,8 ]
Turgeon, T. [1 ,3 ,6 ]
机构
[1] Canadian RSA Network, Winnipeg, MB, Canada
[2] Orthopaed Innovat Ctr, Operat, Winnipeg, MB, Canada
[3] Concordia Joint Replacement Grp, Winnipeg, MB, Canada
[4] Orthopaed Innovat Ctr, Winnipeg, MB, Canada
[5] Western Univ, London Hlth Sci Ctr, London, ON, Canada
[6] Univ Manitoba, Winnipeg, MB, Canada
[7] Dalhousie Univ, QEII Hlth Sci Ctr, Halifax, NS, Canada
[8] Nova Scotia Hlth Author, Halifax, NS, Canada
来源
BONE & JOINT JOURNAL | 2019年 / 101B卷 / 11期
关键词
CROSS-LINKED POLYETHYLENE; VOLUMETRIC WEAR; CAD MODELS; BEARING; RSA; FIXATION;
D O I
10.1302/0301-620X.101B11.BJJ-2018-1447.R2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims A retrospective study was conducted to measure short-term in vivo linear and volumetric wear of polyethylene (PE) inserts in 101 total knee arthroplasty (TKA) patients using model-based radiostereometric analysis (MBRSA). Patients and Methods Nonweightbearing supine RSA exams were performed postoperatively and at six, 12, and 24 months. Weightbearing standing RSA exams were performed on select patients at 12 and 24 months. Wear was measured both linearly (joint space) and volumetrically (digital model overlap) at each available follow-up. Precision of both methods was assessed by comparing double RSA exams. Patient age, sex, body mass index, and Oxford Knee Scores were analyzed for any association with PE wear. Results Linear wear occurred at 0.015 mm/year (supine) and 0.220 mm/year (standing). Volumetric wear occurred at 10.3 mm(3)/year (supine) and 39.3 mm(3)/year (standing). Wear occurred primarily on the medial side of the joint. Weightbearing imaging greatly improved the reliability of measurement. Clinical precision of volumetric wear was 34 mm(3). No significant associations were found between patient demographics or function scores and measured wear. Conclusion In vivo volumetric wear of TKAs can be assessed at short-term follow-up using MBRSA.
引用
收藏
页码:1348 / 1355
页数:8
相关论文
共 50 条
  • [21] Development and Validation of a Wear Model to Predict Polyethylene Wear in a Total Knee Arthroplasty: A Finite Element Analysis
    Innocenti, Bernardo
    Labey, Luc
    Kamali, Amir
    Pascale, Walter
    Pianigiani, Silvia
    LUBRICANTS, 2014, 2 (04): : 193 - 205
  • [22] Tibial Component Fixation with a Peri-Apatite Coating Evaluation by Radiostereometric Analysis in a Canine Total Knee Arthroplasty Model
    Allen, Matthew J.
    Leone, Kendall A.
    Dunbar, Michael J.
    Race, Amos
    Rosenbaum, Paula F.
    Sacks, Jonathan M.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 1138 - 1148
  • [23] The robustness and accuracy of in vivo linear wear measurements for knee prostheses based on model-based RSA
    van Ijsseldijk, E. A.
    Valstar, E. R.
    Stoel, B. C.
    Nelissen, R. G. H. H.
    Reiber, J. H. C.
    Kaptein, B. L.
    JOURNAL OF BIOMECHANICS, 2011, 44 (15) : 2724 - 2727
  • [24] In Vivo Analysis of Polyethylene Wear Particles After Total Knee Arthroplasty: The Influence of Improved Materials and Designs
    Minoda, Yukihide
    Kobayashi, Akio
    Iwaki, Hiroyoshi
    Iwakiri, Kentarou
    Inori, Fumiaki
    Sugama, Ryo
    Ikebuchi, Mitsuhiko
    Kadoya, Yoshinori
    Takaoka, Kunio
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A : 67 - 73
  • [25] The effect of patient positioning on the precision of model-based radiostereometric analysis
    Gascoyne, Trevor C.
    Morrison, Jason B.
    Turgeon, Thomas R.
    JOURNAL OF BIOMECHANICS, 2014, 47 (08) : 1914 - 1917
  • [26] Evaluation of automated radiostereometric image registration in total knee arthroplasty utilizing a synthetic-based and a CT-based volumetric model
    Petersen, Emil Toft
    Vind, Tobias Dahl
    Jurgens-Lahnstein, Jonathan Hugo
    Christensen, Rasmus
    de Raedt, Sepp
    Bruel, Annemarie
    Rytter, Soren
    Andersen, Michael Skipper
    Stilling, Maiken
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (02) : 436 - 446
  • [27] Robotics and the Modern Total Knee Arthroplasty
    Buza, John A., III
    Vigdorchik, Jonathan
    Schwarzkopf, Ran
    TECHNIQUES IN ORTHOPAEDICS, 2018, 33 (01) : 66 - 70
  • [28] Effects of sterilization on wear in total knee arthroplasty
    White, SE
    Paxson, RD
    Tanner, MG
    Whiteside, LA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (331) : 164 - 171
  • [29] Wear and osteolysis around total knee arthroplasty
    Naudie, Douglas D. R.
    Ammeen, Deborah J.
    Engh, Gerard A.
    Rorabeck, Cecil H.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2007, 15 (01) : 53 - 64
  • [30] Dual mobility hip arthroplasty wear measurement: Experimental accuracy assessment using radiostereometric analysis (RSA)
    Pineau, V.
    Lebel, B.
    Gouzy, S.
    Dutheil, J. -J.
    Vielpeau, C.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (06) : 609 - 615