In vivo wear measurement in a modern total knee arthroplasty with model-based radiostereometric analysis

被引:9
|
作者
Gascone, T. [1 ,2 ,3 ]
Parashin, S. [1 ,4 ]
Teeter, M. [1 ,5 ]
Bohm, E. [1 ,3 ,4 ,6 ]
Laende, E. [1 ,7 ,8 ]
Dunbar, M. [1 ,7 ,8 ]
Turgeon, T. [1 ,3 ,6 ]
机构
[1] Canadian RSA Network, Winnipeg, MB, Canada
[2] Orthopaed Innovat Ctr, Operat, Winnipeg, MB, Canada
[3] Concordia Joint Replacement Grp, Winnipeg, MB, Canada
[4] Orthopaed Innovat Ctr, Winnipeg, MB, Canada
[5] Western Univ, London Hlth Sci Ctr, London, ON, Canada
[6] Univ Manitoba, Winnipeg, MB, Canada
[7] Dalhousie Univ, QEII Hlth Sci Ctr, Halifax, NS, Canada
[8] Nova Scotia Hlth Author, Halifax, NS, Canada
来源
BONE & JOINT JOURNAL | 2019年 / 101B卷 / 11期
关键词
CROSS-LINKED POLYETHYLENE; VOLUMETRIC WEAR; CAD MODELS; BEARING; RSA; FIXATION;
D O I
10.1302/0301-620X.101B11.BJJ-2018-1447.R2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims A retrospective study was conducted to measure short-term in vivo linear and volumetric wear of polyethylene (PE) inserts in 101 total knee arthroplasty (TKA) patients using model-based radiostereometric analysis (MBRSA). Patients and Methods Nonweightbearing supine RSA exams were performed postoperatively and at six, 12, and 24 months. Weightbearing standing RSA exams were performed on select patients at 12 and 24 months. Wear was measured both linearly (joint space) and volumetrically (digital model overlap) at each available follow-up. Precision of both methods was assessed by comparing double RSA exams. Patient age, sex, body mass index, and Oxford Knee Scores were analyzed for any association with PE wear. Results Linear wear occurred at 0.015 mm/year (supine) and 0.220 mm/year (standing). Volumetric wear occurred at 10.3 mm(3)/year (supine) and 39.3 mm(3)/year (standing). Wear occurred primarily on the medial side of the joint. Weightbearing imaging greatly improved the reliability of measurement. Clinical precision of volumetric wear was 34 mm(3). No significant associations were found between patient demographics or function scores and measured wear. Conclusion In vivo volumetric wear of TKAs can be assessed at short-term follow-up using MBRSA.
引用
收藏
页码:1348 / 1355
页数:8
相关论文
共 50 条
  • [41] The causes of insert backside wear in total knee arthroplasty
    Wasielewski, RC
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) : 232 - 246
  • [42] Factors affecting polyethylene wear in total knee arthroplasty
    Kuster, MS
    Stachowiak, GW
    ORTHOPEDICS, 2002, 25 (02) : S235 - S242
  • [43] EFFECT OF POLYETHYLENE QUALITY ON WEAR IN TOTAL KNEE ARTHROPLASTY
    TANNER, MG
    WHITESIDE, LA
    WHITE, SE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 83 - 88
  • [44] The influence of slip velocity on wear of total knee arthroplasty
    Schwenke, T
    Borgstede, LL
    Schneider, E
    Andriacchi, TP
    Wimmer, MA
    WEAR, 2005, 259 : 926 - 932
  • [45] In vivo anteroposterior femorotibial translation of total knee arthroplasty: A multicenter analysis
    Dennis, DA
    Komistek, RD
    Colwell, CE
    Ranawat, CS
    Scott, RD
    Thornhill, TS
    Lapp, MA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) : 47 - 57
  • [46] WEAR AND DEFORMATION OF PATELLAR COMPONENTS IN TOTAL KNEE ARTHROPLASTY
    HSU, HP
    WALKER, PS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (246) : 260 - 265
  • [47] In vivo determination of total knee arthroplasty kinematics
    Komistek, Richard D.
    Mahfouz, Mohamed R.
    Bertin, Kim C.
    Rosenberg, Aaron
    Kennedy, William
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 41 - 50
  • [48] Clinical results and in vivo kinematics analysis of osteonics total knee arthroplasty
    Wada, M
    Imura, S
    Basa, H
    JOINT ARTHROPLASTY, 1999, : 255 - 268
  • [49] Soft tissue elasticity in total knee arthroplasty: An in vivo quantitative analysis
    Yang, Dejin
    Zhao, Yongqiang
    Wang, Zhaolun
    Shi, Hongwei
    Huang, Yong
    Zhou, Yixin
    CLINICAL BIOMECHANICS, 2024, 120
  • [50] Wear and Loosening in Total Knee Arthroplasty: A Quick Review
    Fraser, James F.
    Werner, Steven
    Jacofsky, David J.
    JOURNAL OF KNEE SURGERY, 2015, 28 (02) : 139 - 144