In vivo wear measurement in a modern total knee arthroplasty with model-based radiostereometric analysis

被引:9
|
作者
Gascone, T. [1 ,2 ,3 ]
Parashin, S. [1 ,4 ]
Teeter, M. [1 ,5 ]
Bohm, E. [1 ,3 ,4 ,6 ]
Laende, E. [1 ,7 ,8 ]
Dunbar, M. [1 ,7 ,8 ]
Turgeon, T. [1 ,3 ,6 ]
机构
[1] Canadian RSA Network, Winnipeg, MB, Canada
[2] Orthopaed Innovat Ctr, Operat, Winnipeg, MB, Canada
[3] Concordia Joint Replacement Grp, Winnipeg, MB, Canada
[4] Orthopaed Innovat Ctr, Winnipeg, MB, Canada
[5] Western Univ, London Hlth Sci Ctr, London, ON, Canada
[6] Univ Manitoba, Winnipeg, MB, Canada
[7] Dalhousie Univ, QEII Hlth Sci Ctr, Halifax, NS, Canada
[8] Nova Scotia Hlth Author, Halifax, NS, Canada
来源
BONE & JOINT JOURNAL | 2019年 / 101B卷 / 11期
关键词
CROSS-LINKED POLYETHYLENE; VOLUMETRIC WEAR; CAD MODELS; BEARING; RSA; FIXATION;
D O I
10.1302/0301-620X.101B11.BJJ-2018-1447.R2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims A retrospective study was conducted to measure short-term in vivo linear and volumetric wear of polyethylene (PE) inserts in 101 total knee arthroplasty (TKA) patients using model-based radiostereometric analysis (MBRSA). Patients and Methods Nonweightbearing supine RSA exams were performed postoperatively and at six, 12, and 24 months. Weightbearing standing RSA exams were performed on select patients at 12 and 24 months. Wear was measured both linearly (joint space) and volumetrically (digital model overlap) at each available follow-up. Precision of both methods was assessed by comparing double RSA exams. Patient age, sex, body mass index, and Oxford Knee Scores were analyzed for any association with PE wear. Results Linear wear occurred at 0.015 mm/year (supine) and 0.220 mm/year (standing). Volumetric wear occurred at 10.3 mm(3)/year (supine) and 39.3 mm(3)/year (standing). Wear occurred primarily on the medial side of the joint. Weightbearing imaging greatly improved the reliability of measurement. Clinical precision of volumetric wear was 34 mm(3). No significant associations were found between patient demographics or function scores and measured wear. Conclusion In vivo volumetric wear of TKAs can be assessed at short-term follow-up using MBRSA.
引用
收藏
页码:1348 / 1355
页数:8
相关论文
共 50 条
  • [31] Early migration of a medially stabilized total knee arthroplasty A RADIOSTEREOMETRIC ANALYSIS STUDY UP TO TWO YEARS
    Ohrn, F-D
    Lian, O. B.
    Tsukanaka, M.
    Rohrl, S. M.
    BONE & JOINT OPEN, 2021, 2 (09): : 737 - 744
  • [32] CORR Insights® : Radiostereometric Analysis Permits In Vivo Measurement of Very Small Levels of Wear in TKA
    Hopper, Robert H., Jr.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2019, 477 (01) : 91 - 94
  • [33] Inducible displacement of cementless total knee arthroplasty components with conventional and weight-bearing CT-based radiostereometric analysis
    Hext, Rebecca A.
    Kaptein, Bart L.
    Howard, James L.
    Lanting, Brent A.
    Teeter, Matthew G.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2025, 43 (03) : 640 - 649
  • [34] An introduction of various spectroscopic methods to identify in vivo metal wear in total knee arthroplasty
    Kovacik, M. W.
    Gradisarl, A.
    Tokash, J. C.
    Stojilovic, N.
    Ehrman, J. D.
    Bender, E. T.
    Ramsier, R. D.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 84A (04) : 1068 - 1077
  • [35] Wear in total knee arthroplasty—just a question of polyethylene?Metal ion release in total knee arthroplasty
    Jan Philippe Kretzer
    Joern Reinders
    Robert Sonntag
    Sebastien Hagmann
    Marcus Streit
    Sebastian Jeager
    Babak Moradi
    International Orthopaedics, 2014, 38 : 335 - 340
  • [36] Noise measurement in total knee arthroplasty
    Holzer, Lukas A.
    Leithner, Andreas
    Kazianschuetz, Michael
    Gruber, Gerald
    NOISE & HEALTH, 2014, 16 (71): : 205 - 207
  • [37] Mechanical failure of modern total knee arthroplasty
    Goyal, Nitin
    Hozack, Bryan
    Parvizi, Javad
    CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (03): : 236 - 240
  • [38] Conversion of failed modern unicompartmental arthroplasty to total knee arthroplasty
    Levine, WN
    Ozuna, RM
    Scott, RD
    Thornhill, TS
    JOURNAL OF ARTHROPLASTY, 1996, 11 (07): : 797 - 801
  • [39] Prediction of total knee arthroplasty polyethylene wear using the wear index
    Miura, H
    Higaki, H
    Nakanishi, Y
    Mawatari, T
    Moro-oka, T
    Murakami, T
    Iwamoto, Y
    JOURNAL OF ARTHROPLASTY, 2002, 17 (06): : 760 - 766
  • [40] The Effect of Modern Total Knee Arthroplasty on Muscle Balance at the Knee
    Buford, William L., Jr.
    Ivey, F. Marty
    Loveland, Dustin M.
    Flowers, Christopher W.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 7172 - +