A comparison of Monte-Carlo simulated and measured dose distributions in oblique electron beams

被引:1
|
作者
Schweizer, Frederic [1 ]
Christ, Gunter [1 ]
机构
[1] Univ Klinikum Tubingen, Klin Radioonkol, D-72076 Tubingen, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2010年 / 20卷 / 01期
关键词
Electron beams; oblique incidence; treatment planning; Monte-Carlo algorithms;
D O I
10.1016/j.zemedi.2009.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Oblique incidence of electron beams is a rare clinical application which can be used e.g. at the irradiation of the internal mammary lymph nodes in the case of mamma carcinoma. 3-D treatment planning systems are accepted standard for photon beams but not for electron beams. The in for measuring, implementing and testing basic data seems many customers not to be worthwhile when considering the well known inaccuracies of conventional algorithms. From Monte-Carlo (MC) based algorithms however higher accuracies can be expected. It was the aim of this paper to test the MC algorithm of the treatment planning system Oncentra Treatment Planning (OTP, Theranostic) in the application for oblique incidence of electron beams. Measured and simulated values are compared for electron energies from 4 MeV up to 18 Me V. For standard electron applicators, even at extended source-surface distances, satisfying results are achieved. However, the agreement gets lost with increasing oblique incidence, especially for small individual and asymmetrical cut outs. We therefore still use measured values instead of simulated dose distributions.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [1] Comparison of measured and Monte Carlo calculated dose distributions in inhomogeneous phantoms in clinical electron beams
    Doucet, R
    Olivares, M
    DeBlois, F
    Podgorsak, EB
    Kawrakow, I
    Seuntjens, J
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (15): : 2339 - 2354
  • [2] MONTE-CARLO CALCULATION OF ELECTRON DEPTH DOSE DISTRIBUTIONS
    SCHRIBER, SO
    FUNK, LW
    MOWCHENKO, JT
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 573 - 573
  • [3] Comparison of measured and Monte Carlo-calculated electron depth dose distributions in aluminium
    Vandana, S.
    Benny, P. G.
    Selvam, T. Palani
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2018, 56 (01) : 48 - 52
  • [4] Comparison of measured and Monte Carlo calculated dose distributions from circular collimators for radiosurgical beams
    Esnaashari, K. N.
    Allahverdi, M.
    Gharaati, H.
    Shahriari, M.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2007, 5 (01): : 31 - 36
  • [5] MONTE-CARLO GENERATION OF ELECTRON PENCIL BEAMS
    LEVY, SI
    AYYANGAR, K
    SUNTHARALINGAM, N
    MEDICAL PHYSICS, 1983, 10 (04) : 537 - 537
  • [6] Comparison of measured and Monte Carlo calculated dose distributions from the NRC linac
    Sheikh-Bagheri, D
    Rogers, DWO
    Ross, CK
    Seuntjens, JP
    MEDICAL PHYSICS, 2000, 27 (10) : 2256 - 2266
  • [7] COMPARISON OF 4 SCATTER CORRECTION METHODS USING MONTE-CARLO SIMULATED SOURCE DISTRIBUTIONS
    LJUNGBERG, M
    KING, MA
    HADEMENOS, GJ
    STRAND, SE
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (01) : 143 - 151
  • [8] CHARACTERISTICS OF MONTE-CARLO GENERATED ELECTRON PENCIL BEAMS
    BALLON, D
    MOHAN, R
    HAN, K
    CHUI, C
    RILEY, R
    MEDICAL PHYSICS, 1986, 13 (04) : 581 - 581
  • [9] Comparison of RTPS and Monte Carlo Dose Distributions in Heterogeneous Phantoms for Clinical Photon Beams
    Nakaguchi, Y.
    Araki, F.
    Fukuda, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [10] ENERGY BROADENING IN ELECTRON-BEAMS - A COMPARISON OF EXISTING THEORIES AND MONTE-CARLO SIMULATION
    JANSEN, GH
    GROVES, TR
    STICKEL, W
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1985, 3 (01): : 190 - 193