Comparison of RTPS and Monte Carlo Dose Distributions in Heterogeneous Phantoms for Clinical Photon Beams

被引:0
|
作者
Nakaguchi, Y.
Araki, F.
Fukuda, S.
机构
关键词
D O I
10.1118/1.3181804
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-FF-T324
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Comparison of measured and Monte Carlo calculated dose distributions in inhomogeneous phantoms in clinical electron beams
    Doucet, R
    Olivares, M
    DeBlois, F
    Podgorsak, EB
    Kawrakow, I
    Seuntjens, J
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (15): : 2339 - 2354
  • [2] Monte Carlo simulation approaches to dose distributions for 6 MV photon beams in clinical linear accelerator
    Tartar, Ahmet
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2014, 34 (02) : 90 - 100
  • [3] ELECTRON DOSE DISTRIBUTIONS IN INHOMOGENEOUS PHANTOMS: A MONTE CARLO STUDY
    Mihailescu, D.
    Borcia, C.
    ROMANIAN REPORTS IN PHYSICS, 2018, 70 (03)
  • [4] Comparison of PENELOPE Monte Carlo dose calculations with Fricke dosimeter and ionization chamber measurements in heterogeneous phantoms (18 MeV electron and 12 MV photon beams)
    Blazy, L.
    Baltes, D.
    Bordy, J. M.
    Cutarella, D.
    Delaunay, F.
    Gouriou, J.
    Leroy, E.
    Ostrowsky, A.
    Beaumont, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (22): : 5951 - 5965
  • [5] Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation
    Yang, J
    Li, JS
    Qin, L
    Xiong, W
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2657 - 2673
  • [6] Monte Carlo-based correction factors for ion chamber dosimetry in heterogeneous phantoms for megavoltage photon beams
    Araki, Fujio
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22): : 7615 - 7627
  • [7] Monte Carlo N Particle code - Dose distribution of clinical electron beams in inhomogeneous phantoms
    Nedaie, H. A.
    Mosleh-Shirazi, M. A.
    Allahverdi, M.
    JOURNAL OF MEDICAL PHYSICS, 2013, 38 (01) : 15 - 21
  • [8] A comparison of Monte-Carlo simulated and measured dose distributions in oblique electron beams
    Schweizer, Frederic
    Christ, Gunter
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2010, 20 (01): : 17 - 24
  • [9] Accuracy of Monte Carlo Dose Calculations with Kilovoltage Photon Beams
    Bazalova, M.
    Graves, E.
    MEDICAL PHYSICS, 2011, 38 (06) : 3871 - +
  • [10] Validation Tests for CyberKnife® Monte Carlo Dose Calculations Using Heterogeneous Phantoms
    Muniruzzaman, M.
    Dooley, J.
    Kilby, W.
    Lee, M.
    Maurer, C.
    Sims, C.
    MEDICAL PHYSICS, 2008, 35 (06)