A comparison of Monte-Carlo simulated and measured dose distributions in oblique electron beams

被引:1
|
作者
Schweizer, Frederic [1 ]
Christ, Gunter [1 ]
机构
[1] Univ Klinikum Tubingen, Klin Radioonkol, D-72076 Tubingen, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2010年 / 20卷 / 01期
关键词
Electron beams; oblique incidence; treatment planning; Monte-Carlo algorithms;
D O I
10.1016/j.zemedi.2009.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Oblique incidence of electron beams is a rare clinical application which can be used e.g. at the irradiation of the internal mammary lymph nodes in the case of mamma carcinoma. 3-D treatment planning systems are accepted standard for photon beams but not for electron beams. The in for measuring, implementing and testing basic data seems many customers not to be worthwhile when considering the well known inaccuracies of conventional algorithms. From Monte-Carlo (MC) based algorithms however higher accuracies can be expected. It was the aim of this paper to test the MC algorithm of the treatment planning system Oncentra Treatment Planning (OTP, Theranostic) in the application for oblique incidence of electron beams. Measured and simulated values are compared for electron energies from 4 MeV up to 18 Me V. For standard electron applicators, even at extended source-surface distances, satisfying results are achieved. However, the agreement gets lost with increasing oblique incidence, especially for small individual and asymmetrical cut outs. We therefore still use measured values instead of simulated dose distributions.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [11] MONTE-CARLO METHOD FOR DEPTH-DOSE DISTRIBUTIONS FROM DIAGNOSTIC X-RAY BEAMS
    GIBBS, SJ
    KING, RJ
    PUJOL, A
    RADIATION RESEARCH, 1976, 67 (03) : 615 - 615
  • [12] Characterization of computer simulated radiotherapy beams for Monte-Carlo treatment planning
    Ma, CM
    RADIATION PHYSICS AND CHEMISTRY, 1998, 53 (03): : 329 - 344
  • [13] MONTE-CARLO CALCULATION OF DEPTH-DOSE PROFILES OF PULSED ELECTRON-BEAMS IN INP
    LAUGIER, A
    CHEMISTRY, G
    BARBIER, D
    VICARIO, E
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1984, 9 (04): : 259 - 265
  • [14] COMPARISON OF ONETRAN CALCULATIONS OF ELECTRON-BEAM DOSE PROFILES WITH MONTE-CARLO AND EXPERIMENT
    GARTH, JC
    WOOLF, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (06) : 1551 - 1556
  • [15] DISTRIBUTIONS OF ABSORBED DOSE FROM PI-MESON BEAMS CALCULATED FROM A NEW MONTE-CARLO PROGRAM
    BUCHE, G
    PRZYBILLA, G
    NUCLEAR INSTRUMENTS & METHODS, 1981, 179 (02): : 321 - 341
  • [16] Evaluation of an electron Monte Carlo dose calculation algorithm for electron beams
    Hu, Ye Angela
    Song, Haijun
    Chen, Zhe
    Zhou, Sumin
    Yin, Fang-Fang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (03): : 1 - 15
  • [17] Using convolution superposition to guide denoising of Monte-Carlo dose distributions
    El Naqa, I.
    Cui, J.
    Olivera, G.
    Deasy, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2200 - 2200
  • [18] Mitigating inherent noise in Monte-Carlo dose distributions using UNet
    Javaid, U.
    Lee, J.
    Souris, K.
    Huang, S.
    Madrigal, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S44 - S45
  • [19] Evaluation Output Dose of Electron Beams Based On Monte Carlo
    Liu, D.
    Chi, Z.
    Gao, C.
    Han, C.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [20] FITS OF MONTE-CARLO DISTRIBUTIONS TO DATA
    EBERHARD, P
    LYNCH, G
    LAMBERT, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (03): : 574 - 580