Performance of the automated Abbott RealTime™ HIV-1 assay on a genetically diverse panel of specimens from London:: Comparison to VERSANT HIV-1 RNA 3.0, AMPLICOR HIV-1 MONITOR v1.5, and LCx® HIV RNA quantitative assays

被引:44
|
作者
Swanson, Priscilla
Holzmayer, Vera
Huang, Shihai
Hay, Phillip
Adebiyi, Ade
Rice, Philip
Abravaya, Klara
Thamm, Sven
Devare, Sushil G.
Hackett, John, Jr.
机构
[1] Abbott Labs, AIDS Res & Retrovirus Discovery, Abbott Pk, IL 60064 USA
[2] Abbott Mol Inc, Des Plaines, IL USA
[3] Univ London St Georges Hosp, Courtyard Clin, London SW17 0RE, England
关键词
real-time RT-PCR; HIV-1 viral load; HIV-1 genetic diversity;
D O I
10.1016/j.jviromet.2006.06.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Automated RNA extraction and quantitation of HIV-1 by real-time PCR offer potential advantages of efficient sample processing, improved sensitivity, expanded dynamic range and reduced contamination risk. In this study, plasma was collected from 100 HIV-1 infected patients visiting The Courtyard Clinic of St. George's Hospital in London, United Kingdom (UK). Viral loads measured using the automated Abbott RealTime HIV-1 assay (m2000sp sample preparation and m2000rt (TM) amplification and detection instruments) were compared to results obtained with Versant HIV-1 RNA 3.0 (bDNA), AMPLICOR HIV-1 MONITOR v1.5 (Monitor v1.5) and LCx HIV RNA Quantitative (LCx HIV) assays. Based on gag p24, pol integrase, and env gp41 sequences, the panel included 26 subtype A, 20B, 27C, 10D, 1CRF01_AE, 3 CRF02_AG and 13 recombinant viruses. RealTime HIV-1, bDNA, Monitor v 1.5 and LCx HIV quantitated 82,74, 82, and 83% of samples, respectively, with 82, 71,69 and 80 of the 100 samples measured within the dynamic ranges. Viral loads were highly correlated with 99% of values within 1 log(10) copies/ml between tests. The automated m2000 system and RealTime HIV-1 assay can increase laboratory throughput, enhance overall efficiency and reduce operator-associated errors while providing reliable quantitation of genetically diverse strains of HIV-1. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 192
页数:9
相关论文
共 50 条
  • [21] Comparison of the COBAS TAQMAN™ HIV-1HPS with VERSANT HIV-1 RNA 3.0 assay (bDNA) for plasma RNA quantitation indifferent HIV-1 subtypes
    Gomes, Perpetua
    Palma, Ana Carolina
    Cabanas, Joaquim
    Abecasis, Ana
    Carvalho, Ana Patricia
    Ziermann, Rainer
    Diogo, Isabel
    Gonçcalves, Fatima
    Lobo, Ceu Sousa
    Camacho, Ricardo
    JOURNAL OF VIROLOGICAL METHODS, 2006, 135 (02) : 223 - 228
  • [22] Performance of the Abbott Realtime HIV-1: An automated assay for quantification of HIV-1 viral load in plasma.
    Abravaya, K
    Tang, N
    Huang, S
    Cloherty, G
    Mak, W
    Salituro, J
    Robinson, J
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2005, 7 (05): : 670 - 670
  • [23] Quantification of HIV-1 RNA in plasma: Comparable results with the NASBA HIV-1 RNA QT and the AMPLICOR HIV monitor test
    Vandamme, AM
    Schmit, JC
    VanDooren, S
    VanLaethem, K
    Gobbers, E
    Kok, W
    Goubau, P
    Witvrouw, M
    Peetermans, W
    DeClercq, E
    Desmyter, J
    JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 1996, 13 (02) : 127 - 139
  • [24] Performance of the Abbott RealTime™ HIV-1 assay for quantification of HIV-1 clades prevalent in China
    Xu, Sihong
    Song, Aijing
    Li, Xiuhua
    Li, Jingyun
    Bao, Zuoyi
    Mao, Panyong
    Zhao, Qing
    Wang, Youchun
    JOURNAL OF CLINICAL VIROLOGY, 2008, 41 (04) : 305 - 309
  • [25] Comparison of the Generic HIV Viral Load® assay with the Amplicor™ HIV-1 Monitor v1.5 and Nuclisens HIV-1 EasyQ® v1.2 techniques for plasma HIV-1 RNA quantitation of non-B subtypes: The Kesho Bora preparatory study
    Rouet, Francois
    Foulongne, Vincent
    Viljoen, Johannes
    Steegen, Kim
    Becquart, Pierre
    Valea, Diane
    Danaviah, Sivapragashini
    Segondy, Michel
    Verhofstede, Chris
    Van de Perre, Philippe
    JOURNAL OF VIROLOGICAL METHODS, 2010, 163 (02) : 253 - 257
  • [26] Evaluation of the Abbott m2000rt RealTime™ HIV-1 assay with manual sample preparation compared with the ROCHE COBAS® AmpliPrep™/AMPLICOR™ HIV-1 MONITOR® v1.5 using specimens from East Africa
    Crump, John A.
    Scott, Lesley E.
    Msuya, Emma
    Morrissey, Anne B.
    Kimaro, Ekyafyose E.
    Shao, John F.
    Stevens, Wendy S.
    JOURNAL OF VIROLOGICAL METHODS, 2009, 162 (1-2) : 218 - 222
  • [27] Comparison of the bioMerieux NucliSENS EasyQ HIV-1 v2.0-HIV-1 RNA quantification assay versus Abbott RealTime HIV-1 and Roche Cobas TaqMan HIV-1 v2.0 on current epidemic HIV-1 variants
    Mourez, Thomas
    Delaugerre, Constance
    Vray, Muriel
    Lemee, Veronique
    Simon, Francois
    Plantier, Jean-Christophe
    JOURNAL OF CLINICAL VIROLOGY, 2015, 71 : 76 - 81
  • [28] Evaluation of the Aptima® HIV-1 Quant Dx Assay for HIV-1 RNA Viral Load Detection and Quantitation in Plasma of HIV-1-Infected Individuals: A Comparison With Abbott RealTime HIV-1 Assay
    Amendola, Alessandra
    Pisciotta, Maria
    Aleo, Loredana
    Ferraioli, Valeria
    Angeletti, Claudio
    Capobianchi, Maria Rosaria
    JOURNAL OF MEDICAL VIROLOGY, 2016, 88 (09) : 1535 - 1544
  • [29] Comparison of Abbott RealTime HIV-1 and Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Assays
    Abravaya, K.
    Hackett, J.
    Swanson, P.
    Huang, S.
    Tang, N.
    Robinson, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2008, 10 (06): : 587 - 587
  • [30] Comparison of the NucliSENS EasyQ HIV-1 v2.0 with Abbott m2000rt RealTime HIV-1 assay for plasma RNA quantitation in different HIV-1 subtypes
    Gomes, Perpetua
    Carvalho, Ana Patricia
    Diogo, Isabel
    Goncalves, Fatima
    Costa, Ines
    Cabanas, Joaquim
    Camacho, Ricardo Jorge
    JOURNAL OF VIROLOGICAL METHODS, 2013, 193 (01) : 18 - 22