Performance of the automated Abbott RealTime™ HIV-1 assay on a genetically diverse panel of specimens from London:: Comparison to VERSANT HIV-1 RNA 3.0, AMPLICOR HIV-1 MONITOR v1.5, and LCx® HIV RNA quantitative assays

被引:44
|
作者
Swanson, Priscilla
Holzmayer, Vera
Huang, Shihai
Hay, Phillip
Adebiyi, Ade
Rice, Philip
Abravaya, Klara
Thamm, Sven
Devare, Sushil G.
Hackett, John, Jr.
机构
[1] Abbott Labs, AIDS Res & Retrovirus Discovery, Abbott Pk, IL 60064 USA
[2] Abbott Mol Inc, Des Plaines, IL USA
[3] Univ London St Georges Hosp, Courtyard Clin, London SW17 0RE, England
关键词
real-time RT-PCR; HIV-1 viral load; HIV-1 genetic diversity;
D O I
10.1016/j.jviromet.2006.06.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Automated RNA extraction and quantitation of HIV-1 by real-time PCR offer potential advantages of efficient sample processing, improved sensitivity, expanded dynamic range and reduced contamination risk. In this study, plasma was collected from 100 HIV-1 infected patients visiting The Courtyard Clinic of St. George's Hospital in London, United Kingdom (UK). Viral loads measured using the automated Abbott RealTime HIV-1 assay (m2000sp sample preparation and m2000rt (TM) amplification and detection instruments) were compared to results obtained with Versant HIV-1 RNA 3.0 (bDNA), AMPLICOR HIV-1 MONITOR v1.5 (Monitor v1.5) and LCx HIV RNA Quantitative (LCx HIV) assays. Based on gag p24, pol integrase, and env gp41 sequences, the panel included 26 subtype A, 20B, 27C, 10D, 1CRF01_AE, 3 CRF02_AG and 13 recombinant viruses. RealTime HIV-1, bDNA, Monitor v 1.5 and LCx HIV quantitated 82,74, 82, and 83% of samples, respectively, with 82, 71,69 and 80 of the 100 samples measured within the dynamic ranges. Viral loads were highly correlated with 99% of values within 1 log(10) copies/ml between tests. The automated m2000 system and RealTime HIV-1 assay can increase laboratory throughput, enhance overall efficiency and reduce operator-associated errors while providing reliable quantitation of genetically diverse strains of HIV-1. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 192
页数:9
相关论文
共 50 条
  • [41] Development of candidate reference reagent for HIV-1 RNA and comparison analysis for different HIV-1 RNA quantitative assay
    Park, Borae G.
    Park, Ae Ja
    Choi, Jee-Hye
    Park, Jina
    Kim, Sung Soon
    Wang, Jin-Sook
    Kee, Mee Kyung
    Choi, Ju-yeon
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (09) : 1519 - 1524
  • [42] Development of a quantitative assay for HIV-1 RNA
    MacLean, PM
    Levasseur, PJ
    Weinbaum, B
    McCarty, JM
    Burg, JL
    AIDS, 2000, 14 : S108 - S108
  • [43] TaqMan RT-PCR and VERSANT® HIV-1 RNA 3.0 (bDNA) assay -: Quantification of HIV-1 RNA viral load in breast milk
    Israel-Ballard, K
    Ziermann, R
    Leutenegger, C
    Di Canzio, J
    Leung, K
    Strom, L
    Abrams, B
    Chantry, C
    JOURNAL OF CLINICAL VIROLOGY, 2005, 34 (04) : 253 - 256
  • [44] Multicenter evaluation of the Bayer VERSANT™ HIV-1 RNA 3.0 assay:: analytical and clinical performance
    Gleaves, CA
    Welle, J
    Campbell, M
    Elbeik, T
    Ng, V
    Taylor, PE
    Kuramoto, K
    Aceituno, S
    Lewalski, E
    Joppa, B
    Sawyer, L
    Schaper, C
    McNairn, D
    Quinn, T
    JOURNAL OF CLINICAL VIROLOGY, 2002, 25 (02) : 205 - 216
  • [45] Evaluation of Abbott RealTime HIV-1 DBS assay
    Tang, N.
    Pahalawatta, V.
    Frank, A.
    Lampinen, J.
    Leckie, G.
    Bilkovski, R.
    Bagley, Z.
    Viana, R.
    Wallis, C. L.
    Abravaya, K.
    JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2016, 19
  • [46] Performance Characteristics of HIV-1 Culture and HIV-1 DNA and RNA Amplification Assays for Early Diagnosis of Perinatal HIV-1 Infection
    Lambert, John S.
    Harris, D. Robert
    Stiehm, E. Richard
    Moye, John, Jr.
    Fowler, Mary Glenn
    Meyer, William A., III
    Bethel, James
    Mofenson, Lynne M.
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2003, 34 (05) : 512 - 519
  • [47] Comparison of AMPLICOR MONITOR HIV-1 (version 1.0) with AMPLICOR MONITOR HIV-1 (version 1.5) for determination of viral load in HIV-1-infected individuals from Africa.
    Nguyen, CQN
    Hirigoyen, DL
    Schut, R
    Cartwright, CR
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2001, 116 (02) : 279 - 280
  • [48] Evaluation of the Abbott LCx HIV-1 RNA quantitative, a new assay for quantitative determination of human immunodeficiency virus type 1 RNA
    Zanchetta, N
    Nardi, G
    Tocalli, L
    Drago, L
    Bossi, C
    Pulvirenti, FR
    Galli, C
    Gismondo, MR
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (10) : 3882 - 3886
  • [49] Amplicor HIV monitor, NASBA HIV-1 RNA QT and quantiplex HIV RNA version 2.0 viral load assays: a Canadian evaluation
    Prud'homme, IT
    Kim, JE
    Pilon, RG
    Minkus, T
    Hawley-Foss, N
    Cameron, W
    Rud, EW
    JOURNAL OF CLINICAL VIROLOGY, 1998, 11 (03) : 189 - 202
  • [50] Coamplification of HIV-1 Proviral DNA and Viral RNA in Assays Used for Quantification of HIV-1 RNA
    Wan, H.
    Seth, A.
    Rainen, L.
    Fernandes, H.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (06) : 2186 - 2190