Performance of the automated Abbott RealTime™ HIV-1 assay on a genetically diverse panel of specimens from London:: Comparison to VERSANT HIV-1 RNA 3.0, AMPLICOR HIV-1 MONITOR v1.5, and LCx® HIV RNA quantitative assays

被引:44
|
作者
Swanson, Priscilla
Holzmayer, Vera
Huang, Shihai
Hay, Phillip
Adebiyi, Ade
Rice, Philip
Abravaya, Klara
Thamm, Sven
Devare, Sushil G.
Hackett, John, Jr.
机构
[1] Abbott Labs, AIDS Res & Retrovirus Discovery, Abbott Pk, IL 60064 USA
[2] Abbott Mol Inc, Des Plaines, IL USA
[3] Univ London St Georges Hosp, Courtyard Clin, London SW17 0RE, England
关键词
real-time RT-PCR; HIV-1 viral load; HIV-1 genetic diversity;
D O I
10.1016/j.jviromet.2006.06.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Automated RNA extraction and quantitation of HIV-1 by real-time PCR offer potential advantages of efficient sample processing, improved sensitivity, expanded dynamic range and reduced contamination risk. In this study, plasma was collected from 100 HIV-1 infected patients visiting The Courtyard Clinic of St. George's Hospital in London, United Kingdom (UK). Viral loads measured using the automated Abbott RealTime HIV-1 assay (m2000sp sample preparation and m2000rt (TM) amplification and detection instruments) were compared to results obtained with Versant HIV-1 RNA 3.0 (bDNA), AMPLICOR HIV-1 MONITOR v1.5 (Monitor v1.5) and LCx HIV RNA Quantitative (LCx HIV) assays. Based on gag p24, pol integrase, and env gp41 sequences, the panel included 26 subtype A, 20B, 27C, 10D, 1CRF01_AE, 3 CRF02_AG and 13 recombinant viruses. RealTime HIV-1, bDNA, Monitor v 1.5 and LCx HIV quantitated 82,74, 82, and 83% of samples, respectively, with 82, 71,69 and 80 of the 100 samples measured within the dynamic ranges. Viral loads were highly correlated with 99% of values within 1 log(10) copies/ml between tests. The automated m2000 system and RealTime HIV-1 assay can increase laboratory throughput, enhance overall efficiency and reduce operator-associated errors while providing reliable quantitation of genetically diverse strains of HIV-1. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 192
页数:9
相关论文
共 50 条
  • [31] RNA versus DNA (NucliSENS EasyQ HIV-1 v1.2 versus Amplicor HIV-1 DNA Test v1.5) for Early Diagnosis of HIV-1 Infection in Infants in Senegal
    Kebe, K.
    Ndiaye, O.
    Ndiaye, H. Diop
    Mengue, P. Mbakob
    Guindo, P. M. M.
    Diallo, S.
    Leye, N.
    Gueye, S. B.
    Diallo, A. Gaye
    Kane, C. Toure
    Mboup, S.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (07) : 2590 - 2593
  • [32] Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece
    Katsoulidou, Antigoni
    Rokka, Chrysoula
    Issaris, Catherine
    Haida, Catherine
    Tzannis, Kimon
    Sypsa, Vana
    Detsika, Maria
    Paraskevis, Dimitrios
    Hatzakis, Angelos
    VIROLOGY JOURNAL, 2011, 8
  • [33] Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece
    Antigoni Katsoulidou
    Chrysoula Rokka
    Catherine Issaris
    Catherine Haida
    Kimon Tzannis
    Vana Sypsa
    Maria Detsika
    Dimitrios Paraskevis
    Angelos Hatzakis
    Virology Journal, 8
  • [34] Evaluation of the RealTime HIV-1, Xpert HIV-1, and Aptima HIV-1 Quant Dx Assays in Comparison to the NucliSens EasyQ HIV-1 v2.0 Assay for Quantification of HIV-1 Viral Load
    Mor, Orna
    Gozlan, Yael
    Wax, Marina
    Mileguir, Fernando
    Rakovsky, Avia
    Noy, Bina
    Mendelson, Ella
    Levy, Itzchak
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (11) : 3458 - 3465
  • [35] Use of dried blood spots with Abbott RealTime HIV-1 quantitative RNA assay
    Huang, S.
    Erickson, B.
    Abravaya, K.
    Robinson, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2007, 9 (05): : 700 - 700
  • [36] Low Level Virus Load Detection Confidence of Abbott Real-Time HIV-1, Roche TaqMan HIV-1 and Versant HIV-1 RNA (bDNA) Technologies for Quantification of Plasma HIV-1 RNA in HIV-1 Infected Individuals
    Toth, M.
    Davila, L.
    Valiathan, R.
    Deeb, K.
    Young, T. P.
    Cloherty, G.
    Fischl, M.
    Asthana, D.
    Bolivar, H.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2012, 14 (06): : 735 - 736
  • [37] Sensitivity of the COBAS AmpliScreen™ HIV-1 Test v1.5 for HIV-1 detection
    Gomez, Lucia P.
    Balangero, Marcos C.
    Castro, Gonzalo
    Kademian, Silvia
    Mangeaud, Arnaldo
    Barbas, Maria G.
    Cudola, Analia
    de Leon, Juan F.
    Carrizo, Horacio
    Gallego, Sandra V.
    REVISTA ARGENTINA DE MICROBIOLOGIA, 2014, 46 (03): : 196 - 200
  • [38] Quantitative detection of HIV-1 RNA using NucliSens EasyQ HIV-1 assay
    Yao, J
    Liu, Z
    Ko, LS
    Pan, G
    Jiang, Y
    JOURNAL OF VIROLOGICAL METHODS, 2005, 129 (01) : 40 - 46
  • [39] Evaluation of the NucliSens EasyQ HIV-1 v1.1 and RealTime HIV-1 kits for quantitation of HIV-1 RNA in plasma
    Choi, Ju-yeon
    Kim, Eun-Jin
    Rho, Hyun Joo
    Kim, Jin Young
    Kwon, Oh-Kyung
    Lee, Jin-Hee
    Koo, Min Jee
    Kim, Sung Soon
    JOURNAL OF VIROLOGICAL METHODS, 2009, 161 (01) : 7 - 11
  • [40] Validation and Performance of the Abbott RealTime HIV-1 and HCV Assays
    Mazur, L.
    Dylewska, J.
    Nowak, J.
    Sabatini, L.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2008, 10 (06): : 588 - 588