Electrochemical characterization of biosensor based on nitrite reductase and methyl viologen co-immobilized glassy carbon electrode

被引:24
|
作者
Quan, De [1 ]
Min, Dong Geun [1 ]
Cha, Geun Sig [1 ]
Nam, Hakhyun [1 ]
机构
[1] Kwangwoon Univ, Dept Chem, Chem Sensor Res Grp, Seoul 139701, South Korea
关键词
nitrite reductase; methyl viologen; PAH; co-immobilization; biosensor; ALCALIGENES-FAECALIS S-6; X-RAY-STRUCTURE; ACHROMOBACTER CYCLOCLASTES; COPPER; NITRATE;
D O I
10.1016/j.bioelechem.2006.03.030
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Nitrite reductase (NiR, nittic-oxide: ferricytochrome c oxidoreductase, EC 1.7.2.1) and methyl viologen (MV) were co-immobilized on glassy carbon electrode (GCE, d=3 mm) by polymer entrapment, and the electrode was tested as an electrochemical biosensor for amperometric determination of nitrite. The immobilization was performed by sequential loading and drying of a homogeneous mixture of poly(vinyl alcohol) (PVA), NiR and MV, followed by poly(allylamine hydrochloride) (PAH) solution, and finally hydrophilic polyurethane (HPU) dissolved in chloroform. The positively charged PAH layer could effectively keep immobilized cationic MV from diffusing through the membrane, holding mediator tightly near or on the electrode surface. The working principle of the biosensor was based on MV mediated electron transfer between electrode and immobilized NiR. The response time (t(90%)) of the biosensor was about 20 s and sensitivity was 11.8 nA/mu M (2.5 mU NiR) with linear response range of 1.5-260 mu M (r(2)-=0.996) and detection limit of 1.5 mu M (S/N=3). Lineweaver-Burk plot showed that Michaelis-Menten constant (K-m.app) was about 770 mu M. The biosensor showed durable storage stability for 24 days (stored in ambient air at room temperature) retaining 80% of its initial activity, and showed satisfactory reproducibility (relative standard deviation (R.S.D.)=3.8%, n=9). Interference study showed that chlorate, chloride, sulfite, sulfate did not interfere with the nitrite determination, however, nitrate interfered with the determination with relative sensitivity of 38% (ratio of sensitivity for nitrate to that for nitrite). In addition to the full characterization of the biosensor, kinetic study was also conducted in solution and the homogeneous rate constant (k(2)) between NiR and NfV were determined by chronoamperometry to be 5.8 x 10(5) M-1 s(-1). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:267 / 275
页数:9
相关论文
共 50 条
  • [41] A glucose biosensor based on a glassy carbon electrode modified with orthotolidine-methyl anthranilate@MWCNT composites
    Khan, Aftab Aslam Parwaz
    Khan, Anish
    ul Haque, Sufa
    Din, Inamud
    Asiri, Abdullah M.
    MATERIALS RESEARCH EXPRESS, 2019, 6 (06)
  • [42] Electrochemical studies of simvastatin at glassy carbon electrode and immobilized by sodium dodecyl sulfate surfactant
    Deepa, M.B.
    Mamatha, G.P.
    Arthoba Naik, Y.
    Sherigara, B.S.
    Manjappa, S.
    Vijaya, B.
    Journal of Chemical and Pharmaceutical Research, 2012, 4 (05) : 2803 - 2816
  • [43] A Third Generation Glucose Biosensor Based on Cellobiose Dehydrogenase Immobilized on a Glassy Carbon Electrode Decorated with Electrodeposited Gold Nanoparticles: Characterization and Application in Human Saliva
    Bollella, Paolo
    Gorton, Lo
    Ludwig, Roland
    Antiochia, Riccarda
    SENSORS, 2017, 17 (08):
  • [44] A nitrite biosensor based on a maltose binding protein nitrite reductase fusion immobilized on an electropolymerized film of a pyrrole derived bipyridinium
    Wu, Q
    Storrier, GD
    Pariente, F
    Wang, Y
    Shapleigh, JP
    Abruna, HD
    ANALYTICAL CHEMISTRY, 1997, 69 (23) : 4856 - 4863
  • [45] Label-free and ultrasensitive electrochemical transferrin detection biosensor based on a glassy carbon electrode and gold nanoparticles
    Rabbani, Gulam
    Khan, Mohammad Ehtisham
    Khan, Anwar Ulla
    Ali, Syed Kashif
    Zamzami, Mazin A.
    Ahmad, Abrar
    Bashiri, Abdullateef H.
    Zakri, Waleed
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2024, 256
  • [46] Electrochemical behaviour of gold nanoparticles and Co tetraaminophthalocyanine on glassy carbon electrode
    Maringa, Audacity
    Antunes, Edith
    Nyokong, Tebello
    ELECTROCHIMICA ACTA, 2014, 121 : 93 - 101
  • [47] Development of amperometric glucose biosensor based on glucose oxidase co-immobilized with multi-walled carbon nanotubes at low potential
    Rahman, M. M.
    Umar, Ahmad
    Sawada, Kazuaki
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (01): : 327 - 333
  • [48] A sensitive DNA electrochemical biosensor based on magnetite with a glassy carbon electrode modified by muti-walled carbon nanotubes in polypyrrole
    Cheng, GF
    Zhao, J
    Tu, YH
    He, PA
    Fang, YH
    ANALYTICA CHIMICA ACTA, 2005, 533 (01) : 11 - 16
  • [49] Biosensor based on a glassy carbon electrode modified with tyrosinase immmobilized on multiwalled carbon nanotubes
    Ren, Jing
    Kang, Tian-Fang
    Xue, Rui
    Ge, Chao-Nan
    Cheng, Shui-Yuan
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 303 - 309
  • [50] Biosensor based on a glassy carbon electrode modified with tyrosinase immmobilized on multiwalled carbon nanotubes
    Jing Ren
    Tian-Fang Kang
    Rui Xue
    Chao-Nan Ge
    Shui-Yuan Cheng
    Microchimica Acta, 2011, 174 : 303 - 309