Electrochemical characterization of biosensor based on nitrite reductase and methyl viologen co-immobilized glassy carbon electrode

被引:24
|
作者
Quan, De [1 ]
Min, Dong Geun [1 ]
Cha, Geun Sig [1 ]
Nam, Hakhyun [1 ]
机构
[1] Kwangwoon Univ, Dept Chem, Chem Sensor Res Grp, Seoul 139701, South Korea
关键词
nitrite reductase; methyl viologen; PAH; co-immobilization; biosensor; ALCALIGENES-FAECALIS S-6; X-RAY-STRUCTURE; ACHROMOBACTER CYCLOCLASTES; COPPER; NITRATE;
D O I
10.1016/j.bioelechem.2006.03.030
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Nitrite reductase (NiR, nittic-oxide: ferricytochrome c oxidoreductase, EC 1.7.2.1) and methyl viologen (MV) were co-immobilized on glassy carbon electrode (GCE, d=3 mm) by polymer entrapment, and the electrode was tested as an electrochemical biosensor for amperometric determination of nitrite. The immobilization was performed by sequential loading and drying of a homogeneous mixture of poly(vinyl alcohol) (PVA), NiR and MV, followed by poly(allylamine hydrochloride) (PAH) solution, and finally hydrophilic polyurethane (HPU) dissolved in chloroform. The positively charged PAH layer could effectively keep immobilized cationic MV from diffusing through the membrane, holding mediator tightly near or on the electrode surface. The working principle of the biosensor was based on MV mediated electron transfer between electrode and immobilized NiR. The response time (t(90%)) of the biosensor was about 20 s and sensitivity was 11.8 nA/mu M (2.5 mU NiR) with linear response range of 1.5-260 mu M (r(2)-=0.996) and detection limit of 1.5 mu M (S/N=3). Lineweaver-Burk plot showed that Michaelis-Menten constant (K-m.app) was about 770 mu M. The biosensor showed durable storage stability for 24 days (stored in ambient air at room temperature) retaining 80% of its initial activity, and showed satisfactory reproducibility (relative standard deviation (R.S.D.)=3.8%, n=9). Interference study showed that chlorate, chloride, sulfite, sulfate did not interfere with the nitrite determination, however, nitrate interfered with the determination with relative sensitivity of 38% (ratio of sensitivity for nitrate to that for nitrite). In addition to the full characterization of the biosensor, kinetic study was also conducted in solution and the homogeneous rate constant (k(2)) between NiR and NfV were determined by chronoamperometry to be 5.8 x 10(5) M-1 s(-1). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:267 / 275
页数:9
相关论文
共 50 条
  • [31] Electrochemical DNA Biosensor Based on the Immobilization of Probe DNA on a Fulleropyrrolidine Derivative Modified Glassy Carbon Electrode
    Shi Juanlan
    Wang Qingxiang
    Chen Jainping
    Zheng Meixia
    Gao Fei
    ACTA CHIMICA SINICA, 2011, 69 (17) : 2015 - 2020
  • [32] A novel nitrite biosensor based on conductometric electrode modified with cytochrome c nitrite reductase composite membrane
    Zhang, Zhiqiang
    Xia, Siqing
    Leonard, Didier
    Jaffrezic-Renault, Nicole
    Zhang, Jiao
    Bessueille, Francois
    Goepfert, Yves
    Wang, Xuejiang
    Chen, Ling
    Zhu, Zhiliang
    Zhao, Jianfu
    Almeida, M. Gabriela
    Silveira, Celia M.
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (06): : 1574 - 1579
  • [33] Biosensor based on tyrosinase immobilized on a single-walled carbon nanotube-modified glassy carbon electrode for detection of epinephrine
    Apetrei, Irina Mirela
    Apetrei, Constantin
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2013, 8 : 4391 - 4397
  • [34] Novel BOD optical fiber biosensor based on co-immobilized microorganisms in ormosils matrix
    Lin, L
    Xiao, LL
    Huang, S
    Zhao, L
    Cui, JS
    Wang, XH
    Chen, X
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (09): : 1703 - 1709
  • [35] The graphene/polypyrrole/chitosan-modified glassy carbon electrode for electrochemical nitrite detection
    Qi Xiao
    Mengmeng Feng
    Yi Liu
    Shuangyan Lu
    Yingzi He
    Shan Huang
    Ionics, 2018, 24 : 845 - 859
  • [36] Electrochemical determination of nitrite at a bare glassy carbon electrode; why chemically modify electrodes?
    Kozub, Barbara R.
    Rees, Neil V.
    Compton, Richard G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 143 (02): : 539 - 546
  • [37] The graphene/polypyrrole/chitosan-modified glassy carbon electrode for electrochemical nitrite detection
    Xiao, Qi
    Feng, Mengmeng
    Liu, Yi
    Lu, Shuangyan
    He, Yingzi
    Huang, Shan
    IONICS, 2018, 24 (03) : 845 - 859
  • [38] Development of a new electrochemical sensor for verapamil based on multi-walled carbon nanotube immobilized on glassy carbon electrode
    Chamjangali, M. Arab
    Goudarzi, N.
    Bagherian, G.
    Reskety, A. Ahmadi
    MEASUREMENT, 2015, 71 : 23 - 30
  • [39] Glucose Biosensor Based on Glucose Oxidase Immobilized on BSA Cross-Linked Nanocomposite Modified Glassy Carbon Electrode
    Li, Yang-Yang
    Ma, Xin-Xin
    Song, Xin-Yan
    Ma, Lin-Lin
    Li, Yu-Ying
    Meng, Xin
    Chen, Yu-Jie
    Xu, Ke-Xin
    Moosavi-Movahedi, Ali Akbar
    Xiao, Bao-Lin
    Hong, Jun
    SENSORS, 2023, 23 (06)
  • [40] A hydrogen peroxide biosensor based on cytochrome c immobilized graphene-L-cysteine modified glassy carbon electrode
    Kong, Bo
    Liu, Wei
    Li, Qiang
    Chen, Lijuan
    Liu, Xiaoying
    Zhou, Jiheng
    Sensor Letters, 2015, 13 (04) : 267 - 272