Electrochemical characterization of biosensor based on nitrite reductase and methyl viologen co-immobilized glassy carbon electrode

被引:24
|
作者
Quan, De [1 ]
Min, Dong Geun [1 ]
Cha, Geun Sig [1 ]
Nam, Hakhyun [1 ]
机构
[1] Kwangwoon Univ, Dept Chem, Chem Sensor Res Grp, Seoul 139701, South Korea
关键词
nitrite reductase; methyl viologen; PAH; co-immobilization; biosensor; ALCALIGENES-FAECALIS S-6; X-RAY-STRUCTURE; ACHROMOBACTER CYCLOCLASTES; COPPER; NITRATE;
D O I
10.1016/j.bioelechem.2006.03.030
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Nitrite reductase (NiR, nittic-oxide: ferricytochrome c oxidoreductase, EC 1.7.2.1) and methyl viologen (MV) were co-immobilized on glassy carbon electrode (GCE, d=3 mm) by polymer entrapment, and the electrode was tested as an electrochemical biosensor for amperometric determination of nitrite. The immobilization was performed by sequential loading and drying of a homogeneous mixture of poly(vinyl alcohol) (PVA), NiR and MV, followed by poly(allylamine hydrochloride) (PAH) solution, and finally hydrophilic polyurethane (HPU) dissolved in chloroform. The positively charged PAH layer could effectively keep immobilized cationic MV from diffusing through the membrane, holding mediator tightly near or on the electrode surface. The working principle of the biosensor was based on MV mediated electron transfer between electrode and immobilized NiR. The response time (t(90%)) of the biosensor was about 20 s and sensitivity was 11.8 nA/mu M (2.5 mU NiR) with linear response range of 1.5-260 mu M (r(2)-=0.996) and detection limit of 1.5 mu M (S/N=3). Lineweaver-Burk plot showed that Michaelis-Menten constant (K-m.app) was about 770 mu M. The biosensor showed durable storage stability for 24 days (stored in ambient air at room temperature) retaining 80% of its initial activity, and showed satisfactory reproducibility (relative standard deviation (R.S.D.)=3.8%, n=9). Interference study showed that chlorate, chloride, sulfite, sulfate did not interfere with the nitrite determination, however, nitrate interfered with the determination with relative sensitivity of 38% (ratio of sensitivity for nitrate to that for nitrite). In addition to the full characterization of the biosensor, kinetic study was also conducted in solution and the homogeneous rate constant (k(2)) between NiR and NfV were determined by chronoamperometry to be 5.8 x 10(5) M-1 s(-1). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:267 / 275
页数:9
相关论文
共 50 条
  • [21] A Mexacarbate Electrochemical Biosensor on Carbon Materials Based on a Functionalized Multiwalled Carbon Nanotube Modified Glassy Carbon Electrode
    Tharini, J.
    Chen, Tse-Wei
    Chen, Shen-Ming
    Saraswathi, R.
    Elshikh, Mohamed S.
    Darwish, Noura M.
    Rwei, Syang-Peng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (08): : 8311 - 8325
  • [22] ELECTROCHEMICAL SENSOR OF NITRITE BASED ON AN INORGANIC FILM-MODIFIED GLASSY-CARBON ELECTRODE
    GAO, ZQ
    ZI, MX
    ZHANG, Y
    WANG, GQ
    ZHAO, ZF
    MIKROCHIMICA ACTA, 1993, 111 (1-3) : 63 - 70
  • [23] A novel electrochemical biosensor based on TetX2 monooxygenase immobilized on a nano-porous glassy carbon electrode for tetracycline residue detection
    Besharati, Maryam
    Hamedi, Javad
    Hosseinkhani, Saman
    Saber, Reza
    BIOELECTROCHEMISTRY, 2019, 128 : 66 - 73
  • [24] A norepinephrine biosensor based on a glassy carbon electrode modified with carbon nanotubes
    Mohammadi, Ali
    Moghaddam, Abdolmajid Bayandori
    Hosseini, Samanesadat
    Kazemzad, Mahmood
    Dinarvand, Rassoul
    ANALYTICAL METHODS, 2011, 3 (10) : 2406 - 2411
  • [25] Conductometric nitrate biosensor based on methyl viologen/Nafion®/nitrate reductase interdigitated electrodes
    Wang, XJ
    Dzyadevych, SV
    Chovelon, JM
    Renault, NJ
    Ling, C
    Xia, SQ
    Zhao, JF
    TALANTA, 2006, 69 (02) : 450 - 455
  • [26] Simple Approach to Fabricate a Highly Sensitive H2O2 Biosensor by One-Step of Graphene Oxide and Horseradish Peroxidase Co-immobilized Glassy Carbon Electrode
    Wang, Yue
    Zhao, KeJuan
    Zhang, Zhiqiang
    Jia, Hongmin
    Chen, Jiaqi
    Fu, Chen
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (03): : 2921 - 2933
  • [27] Amperometric urea biosensor using aminated glassy carbon electrode covered with urease immobilized carbon sheet, based on the electrode oxidation of carbamic acid
    Wang, Xiuyun
    Watanabe, Hiroaki
    Sekioka, Naoyuki
    Hamana, Hiroshi
    Uchiyama, Shunichi
    ELECTROANALYSIS, 2007, 19 (12) : 1300 - 1306
  • [28] Electrochemical detection of nitrite based on glassy carbon electrode modified with gold-polyaniline-graphene nanocomposites
    Ma, Xuemei
    Miao, Tingting
    Zhu, Wencai
    Gao, Xiaochun
    Wang, Chuntao
    Zhao, Caicai
    Ma, Houyi
    RSC ADVANCES, 2014, 4 (101) : 57842 - 57849
  • [29] Determination of Glucose using a Biosensor Based on Glucose Oxidase Immobilized on a Molybdenite-Decorated Glassy Carbon Electrode
    Zhao, Rui
    Wang, Yue
    Hasebe, Yasushi
    Zhang, Zhiqiang
    Tao, Dongping
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (02): : 1595 - 1605
  • [30] Hydrogen peroxide biosensor based on myoglobin/colloidal gold nanoparticles immobilized on glassy carbon electrode by a Nafion film
    Yang, WW
    Li, YC
    Bai, Y
    Sun, CQ
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 115 (01) : 42 - 48