Determination of Vanadium Isotope Compositions in Carbonates Using an Fe Coprecipitation Method and MC-ICP-MS

被引:16
|
作者
Dong, Lin-Hui [1 ]
Wei, Wei [1 ]
Yu, Cheng-Long [1 ]
Hou, Zhen-Hui [1 ,2 ]
Zeng, Zhen [3 ]
Chen, Tianyu [4 ]
Huang, Fang [1 ,2 ]
机构
[1] Univ Sci & Technol China, Sch Earth & Space Sci, CAS Key Lab Mantel Mat & Environm, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, CAS Ctr Excellence Comparat Planetol, Hefei 230026, Anhui, Peoples R China
[3] Chinese Acad Sci, Inst Soil Sci, State Key Lab Soil & Sustainable Agr, Nanjing 210008, Jiangsu, Peoples R China
[4] Nanjing Univ, Sch Earth Sci & Engn, State Key Lab Mineral Deposits Res, Nanjing 210023, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
CHROMIUM ISOTOPES; TRACE-METALS; CR-ISOTOPE; OXYGENATION; ADSORPTION; FRACTIONATION; COMPLEXATION; ACCUMULATION; MOLYBDENUM; ATMOSPHERE;
D O I
10.1021/acs.analchem.0c04800
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vanadium isotope compositions (delta(V-51)) in marine carbonates are a potential proxy to trace global redox states of ancient oceans. Although high-precision delta(V-51) analyses are available for many geological materials, carbonate-hosted delta(V-51) data have not been reported yet due to extremely high matrix elements and low V contents (generally below 10 mu g g(-1)). In this study, we developed an Fe coprecipitation method combined with an Fe column to preconcentrate V from the major matrix elements and subsequent four-step chromatographic procedures to further purify V in carbonates. The delta(V-51) values were measured using a sample-standard bracketing method by MC-ICP-MS. The robustness of this method was assessed by analyzing element-doped and matrix-spiked synthetic carbonate solutions containing an in-house delta(V-51) standard, USTC-V. The mean delta(V-51) value of the synthetic carbonate solutions (0.06 +/- 0.08%; 2SD, n = 33) is in good agreement with the recommended value of the USTC-V relative to the Oxford AA solution (0.07 +/- 0.08%; 2SD, n = 347). In addition, the consistency in the delta(V-51) value of the igneous carbonatite standard, COQ-1, which was processed in parallel with the whole purification (- 0.48 +/- 0.04%; 2SD, n = 3) and a four-step chromatographic procedure (-0.43 +/- 0.08%; 2SD, n = 3), further validates the robustness of our method. For the first time, we obtained delta(V-51) values of four carbonate reference materials: JDo-1, -0.56 +/- 0.09% (2SD, n = 27); JLs-1, -0.61 +/- 0.14% (2SD, n = 33); GBW07217a, -0.79 +/- 0.09% (2SD, n = 6); GBW07214a, -0.51 +/- 0.13% (2SD, n = 48). The long-term external precision of carbonate-hosted delta(V-51) analyses is better than +/- 0.14% (2SD). Our method can be applied to measure carbonate-hosted delta(V-51) to trace the evolution in global marine redox states throughout the Earth's history.
引用
收藏
页码:7172 / 7179
页数:8
相关论文
共 50 条
  • [31] Ce and Nd stable isotope purification and determination of geological samples by MC-ICP-MS
    Bai, Jiang-Hao
    Ma, Jin-Long
    Wei, Gang-Jian
    Zhang, Le
    Zhong, Song-Xiong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (08) : 1618 - 1628
  • [32] Plutonium and uranium isotope ratio measurement by MC-ICP-MS
    Taylor, RN
    Warneke, T
    Croudace, IW
    Milton, JA
    Warwick, PE
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A766 - A766
  • [33] A Method for Rapid Determination of Re and Os Isotope Compositions Using ID-MC-ICP-MS Combined with the Sparging Method
    Nozaki, Tatsuo
    Suzuki, Katsuhiko
    Ravizza, Gregory
    Kimura, Jun-Ichi
    Chang, Qing
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2012, 36 (02) : 131 - 148
  • [34] Precise determination of the isotopic composition of Sn using MC-ICP-MS
    Clayton, R
    Andersson, P
    Gale, NH
    Gillis, C
    Whitehouse, MJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) : 1248 - 1256
  • [35] Precise determination of lithium isotopes in seawater using MC-ICP-MS
    Choi, Min Seok
    Shin, Hyung Seon
    Kil, Young Woo
    MICROCHEMICAL JOURNAL, 2010, 95 (02) : 274 - 278
  • [36] Measurement of isotope ratios on transient signals by MC-ICP-MS
    Günther-Leopold, I
    Wernli, B
    Kopajtic, Z
    Günther, D
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) : 241 - 249
  • [37] A Review of Mg Isotope Analytical Methods by MC-ICP-MS
    Yajun An
    Fang Huang
    Journal of Earth Science, 2014, (05) : 822 - 840
  • [38] A Review of Mg Isotope Analytical Methods by MC-ICP-MS
    An, Yajun
    Huang, Fang
    JOURNAL OF EARTH SCIENCE, 2014, 25 (05) : 822 - 840
  • [39] High precision Rb isotope measurements by MC-ICP-MS
    Hu, Xia
    Nan, Xiao-Yun
    Yu, Hui-Min
    Huang, Fang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (12) : 2744 - 2755
  • [40] A review of Mg isotope analytical methods by MC-ICP-MS
    Yajun An
    Fang Huang
    Journal of Earth Science, 2014, 25 : 822 - 840