Determination of Vanadium Isotope Compositions in Carbonates Using an Fe Coprecipitation Method and MC-ICP-MS

被引:16
|
作者
Dong, Lin-Hui [1 ]
Wei, Wei [1 ]
Yu, Cheng-Long [1 ]
Hou, Zhen-Hui [1 ,2 ]
Zeng, Zhen [3 ]
Chen, Tianyu [4 ]
Huang, Fang [1 ,2 ]
机构
[1] Univ Sci & Technol China, Sch Earth & Space Sci, CAS Key Lab Mantel Mat & Environm, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, CAS Ctr Excellence Comparat Planetol, Hefei 230026, Anhui, Peoples R China
[3] Chinese Acad Sci, Inst Soil Sci, State Key Lab Soil & Sustainable Agr, Nanjing 210008, Jiangsu, Peoples R China
[4] Nanjing Univ, Sch Earth Sci & Engn, State Key Lab Mineral Deposits Res, Nanjing 210023, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
CHROMIUM ISOTOPES; TRACE-METALS; CR-ISOTOPE; OXYGENATION; ADSORPTION; FRACTIONATION; COMPLEXATION; ACCUMULATION; MOLYBDENUM; ATMOSPHERE;
D O I
10.1021/acs.analchem.0c04800
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vanadium isotope compositions (delta(V-51)) in marine carbonates are a potential proxy to trace global redox states of ancient oceans. Although high-precision delta(V-51) analyses are available for many geological materials, carbonate-hosted delta(V-51) data have not been reported yet due to extremely high matrix elements and low V contents (generally below 10 mu g g(-1)). In this study, we developed an Fe coprecipitation method combined with an Fe column to preconcentrate V from the major matrix elements and subsequent four-step chromatographic procedures to further purify V in carbonates. The delta(V-51) values were measured using a sample-standard bracketing method by MC-ICP-MS. The robustness of this method was assessed by analyzing element-doped and matrix-spiked synthetic carbonate solutions containing an in-house delta(V-51) standard, USTC-V. The mean delta(V-51) value of the synthetic carbonate solutions (0.06 +/- 0.08%; 2SD, n = 33) is in good agreement with the recommended value of the USTC-V relative to the Oxford AA solution (0.07 +/- 0.08%; 2SD, n = 347). In addition, the consistency in the delta(V-51) value of the igneous carbonatite standard, COQ-1, which was processed in parallel with the whole purification (- 0.48 +/- 0.04%; 2SD, n = 3) and a four-step chromatographic procedure (-0.43 +/- 0.08%; 2SD, n = 3), further validates the robustness of our method. For the first time, we obtained delta(V-51) values of four carbonate reference materials: JDo-1, -0.56 +/- 0.09% (2SD, n = 27); JLs-1, -0.61 +/- 0.14% (2SD, n = 33); GBW07217a, -0.79 +/- 0.09% (2SD, n = 6); GBW07214a, -0.51 +/- 0.13% (2SD, n = 48). The long-term external precision of carbonate-hosted delta(V-51) analyses is better than +/- 0.14% (2SD). Our method can be applied to measure carbonate-hosted delta(V-51) to trace the evolution in global marine redox states throughout the Earth's history.
引用
收藏
页码:7172 / 7179
页数:8
相关论文
共 50 条
  • [21] Iron, copper and zinc isotope compositions of biological reference materials determined by MC-ICP-MS
    Guo, Rui
    Yu, Hui-Min
    Fang, Shu-Bin
    Xiao, Zi-Cong
    Huang, Fang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (11) : 2365 - 2377
  • [22] An Analytical Method for Quantification of Sn Isotope Variations in Geological Materials Using MC-ICP-MS
    Pathak, Dipankar
    Mezger, Klaus
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024, 48 (04) : 863 - 885
  • [23] Analysis of high-precision vanadium isotope ratios by medium resolution MC-ICP-MS
    Nielsen, Sune G.
    Owens, Jeremy D.
    Horner, Tristan J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (02) : 531 - 536
  • [24] A comparison of zircon Hf isotope analyses by MC-ICP-MS and LA-MC-ICP-MS
    Zhang, L
    Han, BF
    Gu, LB
    Zhang, WH
    Xie, LW
    Yang, YH
    ACTA PETROLOGICA SINICA, 2006, 22 (02) : 510 - 512
  • [25] Optimizing MC-ICP-MS with SEM protocols for determination of U and Th isotope ratios and 230Th ages in carbonates
    Chiang, Hong-Wei
    Lu, Yanbin
    Wang, Xianfeng
    Lin, Ke
    Liu, Xiaokang
    QUATERNARY GEOCHRONOLOGY, 2019, 50 : 75 - 90
  • [26] Precise determination of the lithium isotope ratio in geological samples using MC-ICP-MS with cool plasma
    Choi, Min Seok
    Ryu, Jong-Sik
    Park, Ha Yan
    Lee, Kwang-Sik
    Kil, Youngwoo
    Shin, Hyung Seon
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (04) : 505 - 509
  • [27] U-Th-Pb chronology in pleistocene carbonates using MC-ICP-MS
    Becker, ML
    Henderson, GM
    Belshaw, NS
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A60 - A60
  • [28] Calcium isotope measurements using a collision cell (CC)-MC-ICP-MS
    Dai, Wei
    Moynier, Frederic
    Paquet, Marine
    Moureau, Julien
    Debret, Baptiste
    Siebert, Julien
    Gerard, Yvan
    Zhao, Ye
    CHEMICAL GEOLOGY, 2022, 590
  • [29] High precision determination of chromium isotope ratios in geological samples by MC-ICP-MS
    Halicz, Ludwik
    Yang, Lu
    Teplyakov, Nataliya
    Burg, Avihu
    Sturgeon, Ralph
    Kolodny, Yehoshua
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (12) : 1622 - 1627
  • [30] High precision determination of silver isotope ratios in commercial products by MC-ICP-MS
    Yang, Lu
    Dabek-Zlotorzynska, Ewa
    Celo, Valbona
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (11) : 1564 - 1569