Determination of Vanadium Isotope Compositions in Carbonates Using an Fe Coprecipitation Method and MC-ICP-MS

被引:16
|
作者
Dong, Lin-Hui [1 ]
Wei, Wei [1 ]
Yu, Cheng-Long [1 ]
Hou, Zhen-Hui [1 ,2 ]
Zeng, Zhen [3 ]
Chen, Tianyu [4 ]
Huang, Fang [1 ,2 ]
机构
[1] Univ Sci & Technol China, Sch Earth & Space Sci, CAS Key Lab Mantel Mat & Environm, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, CAS Ctr Excellence Comparat Planetol, Hefei 230026, Anhui, Peoples R China
[3] Chinese Acad Sci, Inst Soil Sci, State Key Lab Soil & Sustainable Agr, Nanjing 210008, Jiangsu, Peoples R China
[4] Nanjing Univ, Sch Earth Sci & Engn, State Key Lab Mineral Deposits Res, Nanjing 210023, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
CHROMIUM ISOTOPES; TRACE-METALS; CR-ISOTOPE; OXYGENATION; ADSORPTION; FRACTIONATION; COMPLEXATION; ACCUMULATION; MOLYBDENUM; ATMOSPHERE;
D O I
10.1021/acs.analchem.0c04800
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vanadium isotope compositions (delta(V-51)) in marine carbonates are a potential proxy to trace global redox states of ancient oceans. Although high-precision delta(V-51) analyses are available for many geological materials, carbonate-hosted delta(V-51) data have not been reported yet due to extremely high matrix elements and low V contents (generally below 10 mu g g(-1)). In this study, we developed an Fe coprecipitation method combined with an Fe column to preconcentrate V from the major matrix elements and subsequent four-step chromatographic procedures to further purify V in carbonates. The delta(V-51) values were measured using a sample-standard bracketing method by MC-ICP-MS. The robustness of this method was assessed by analyzing element-doped and matrix-spiked synthetic carbonate solutions containing an in-house delta(V-51) standard, USTC-V. The mean delta(V-51) value of the synthetic carbonate solutions (0.06 +/- 0.08%; 2SD, n = 33) is in good agreement with the recommended value of the USTC-V relative to the Oxford AA solution (0.07 +/- 0.08%; 2SD, n = 347). In addition, the consistency in the delta(V-51) value of the igneous carbonatite standard, COQ-1, which was processed in parallel with the whole purification (- 0.48 +/- 0.04%; 2SD, n = 3) and a four-step chromatographic procedure (-0.43 +/- 0.08%; 2SD, n = 3), further validates the robustness of our method. For the first time, we obtained delta(V-51) values of four carbonate reference materials: JDo-1, -0.56 +/- 0.09% (2SD, n = 27); JLs-1, -0.61 +/- 0.14% (2SD, n = 33); GBW07217a, -0.79 +/- 0.09% (2SD, n = 6); GBW07214a, -0.51 +/- 0.13% (2SD, n = 48). The long-term external precision of carbonate-hosted delta(V-51) analyses is better than +/- 0.14% (2SD). Our method can be applied to measure carbonate-hosted delta(V-51) to trace the evolution in global marine redox states throughout the Earth's history.
引用
收藏
页码:7172 / 7179
页数:8
相关论文
共 50 条
  • [41] A Review of Mg Isotope Analytical Methods by MC-ICP-MS
    Yajun An
    Fang Huang
    Journal of Earth Science, 2014, 25 (05) : 822 - 840
  • [42] A revisited method for Mg purification and isotope analysis using cool-plasma MC-ICP-MS
    Choi, Min Seok
    Ryu, Jong-Sik
    Lee, Sin-Woo
    Shin, Hyung Seon
    Lee, Kwang-Sik
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (11) : 1955 - 1959
  • [43] A novel chemical purification method for accurate Sn isotope measurement by MC-ICP-MS
    Qu, Qinyuan
    Liu, Wengang
    Zheng, Wang
    Chetelat, Benjamin
    Liu, Qingchuan
    Chen, Jiubin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (09) : 2258 - 2269
  • [44] A common matrix method for precise and accurate isotope ratio measurement by MC-ICP-MS
    Barling, Jane
    Weis, Dominique
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A56 - A56
  • [45] Precise determination of U isotopic compositions in low concentration carbonate samples by MC-ICP-MS
    Wang, Ruo-Mei
    You, Chen-Feng
    TALANTA, 2013, 107 : 67 - 73
  • [46] A simple method for obtaining highly accurate Pb isotope data by MC-ICP-MS
    Woodhead, J
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) : 1381 - 1385
  • [47] High-precision magnesium isotope analysis of carbonates by laser ablation MC-ICP-MS using wet and dry conditions
    Lu, Jue
    Chen, Wei
    Sun, Jian
    Lin, Jie
    Luo, Tao
    Liu, Yong-Hong
    Zhao, Kui-Dong
    Jiang, Shao-Yong
    Liu, Yong-Sheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (08) : 1665 - 1674
  • [48] Isobaric Spike Method for Absolute Isotopic Ratio Determination by MC-ICP-MS
    Shuai, Kang
    Li, Weiqiang
    Hui, Hejiu
    ANALYTICAL CHEMISTRY, 2020, 92 (07) : 4820 - 4828
  • [49] Single laboratory comparison of MC-ICP-MS and N-TIMS boron isotope analyses in marine carbonates
    Farmer, Jesse R.
    Honisch, Barbel
    Uchikawa, Joji
    CHEMICAL GEOLOGY, 2016, 447 : 173 - 182
  • [50] Rapid Two-Column Separation Method for Determining Barium Isotopic Compositions Using MC-ICP-MS
    Cheng, Yishan
    Du, Yifan
    Chen, Kaiyun
    Zang, Chunlei
    Zhao, Jian
    Chen, Li-Hui
    ATOMIC SPECTROSCOPY, 2022, 43 (03) : 236 - 245