共 50 条
A Method for Rapid Determination of Re and Os Isotope Compositions Using ID-MC-ICP-MS Combined with the Sparging Method
被引:43
|作者:
Nozaki, Tatsuo
[1
,2
]
Suzuki, Katsuhiko
[1
,2
,3
]
Ravizza, Gregory
[4
]
Kimura, Jun-Ichi
[1
]
Chang, Qing
[1
,2
]
机构:
[1] Japan Agcy Marine Earth Sci & Technol, Inst Res Earth Evolut, Yokosuka, Kanagawa 2370061, Japan
[2] Japan Agcy Marine Earth Sci & Technol, Submarine Resources Res Project, Yokosuka, Kanagawa 2370061, Japan
[3] Japan Agcy Marine Earth Sci & Technol, Precambrian Ecosyst Lab, Yokosuka, Kanagawa 2370061, Japan
[4] Univ Hawaii Manoa, SOEST, Dept Geol & Geophys, Honolulu, HI 96822 USA
基金:
美国国家科学基金会;
关键词:
Re-Os isotopes;
MC-ICP-MS;
multi-ion-counter;
sparging method;
geochemical reference materials;
isotopes du Re et de l'Os;
multi-compteurs d'ions;
methode de barbotage;
materiaux geochimiques de reference;
PLASMA-MASS-SPECTROMETRY;
REFERENCE SAMPLES;
OSMIUM ISOTOPES;
RHENIUM;
RATIO;
SYSTEMATICS;
PRECISE;
OS-186/OS-188;
SEPARATION;
DIGESTION;
D O I:
10.1111/j.1751-908X.2011.00125.x
中图分类号:
P3 [地球物理学];
P59 [地球化学];
学科分类号:
0708 ;
070902 ;
摘要:
A simple, rapid method for the determination of Re and Os concentrations and isotope compositions using isotope dilution multi-collector inductively coupled plasma-mass spectrometry (ID-MC-ICP-MS) combined with Carius tube digestion and sparging introduction of Os was developed. For Os measurement, four channeltron ion counters to detect different Os isotopes were used simultaneously, which led to a drastic reduction in the measurement time. Rhenium isotopes were measured by means of eight Faraday cups with solution nebulisation and an ultrasonic membrane desolvator. The representative 188Os count rate of an Os standard solution containing 50 pg of total Os was approximately 110000120000 cps at the onset of measurement; the Re intensity of our in-house 10 pg g-1 standard solution reached 1820 V/mu g g-1 with a sample uptake rate of 9599 mu l min-1. These values indicate that the sensitivity of the method was sufficient even for samples with low Re and Os concentrations, such as chert. As the temporal variations of the amplification efficiency of the ion counters differed from one another, we adopted a sample-calibrator bracketing method to correct the measured Re and Os isotope ratios. The Re and Os concentrations via the isotope dilution method and the 187Os/188Os ratios of two sedimentary rock reference materials (JMS-2 and JCh-1) on the basis of the isotope ratios determined by the MC-ICP-MS and by negative thermal ionisation mass spectrometry (N-TIMS) were comparable within their ranges. Based on Os isotope measurement of the IAG reference material [Durham Romil Os (DROsS)], the average difference from the recommended value and precision of Os isotope measurements by the sparging method in combination with multi-ion-counters were 0.72% and 0.76% [1RSD (%), n = 29], respectively. The precisions in the 187Os/188Os ratios [1RSD (%)] of JMS-2, JCh-1 and DROsS were 0.350.71, 1.563.31 and 0.991.28%, respectively, which depended on their Os ion intensities. No systematic difference was observed between the Re and Os geochemical compositions of JCh-1 and JMS-2 obtained by means of digestion with inverse aqua regia and CrO3-H2SO4 solutions, suggesting that either acid solution can be used for the sparging method of sedimentary rock samples. As CrO3-H2SO4 solution is believed to liberate predominantly the hydrogenous Re and Os fraction from organic-rich sediment, the sparging method combined with CrO3-H2SO4 digestion and multi-ion-counters in the mass spectrometry is expected to be a powerful tool for reconstructing the secular change in marine Os isotope compositions with high sample throughput.
引用
收藏
页码:131 / 148
页数:18
相关论文