A Method for Rapid Determination of Re and Os Isotope Compositions Using ID-MC-ICP-MS Combined with the Sparging Method

被引:43
|
作者
Nozaki, Tatsuo [1 ,2 ]
Suzuki, Katsuhiko [1 ,2 ,3 ]
Ravizza, Gregory [4 ]
Kimura, Jun-Ichi [1 ]
Chang, Qing [1 ,2 ]
机构
[1] Japan Agcy Marine Earth Sci & Technol, Inst Res Earth Evolut, Yokosuka, Kanagawa 2370061, Japan
[2] Japan Agcy Marine Earth Sci & Technol, Submarine Resources Res Project, Yokosuka, Kanagawa 2370061, Japan
[3] Japan Agcy Marine Earth Sci & Technol, Precambrian Ecosyst Lab, Yokosuka, Kanagawa 2370061, Japan
[4] Univ Hawaii Manoa, SOEST, Dept Geol & Geophys, Honolulu, HI 96822 USA
基金
美国国家科学基金会;
关键词
Re-Os isotopes; MC-ICP-MS; multi-ion-counter; sparging method; geochemical reference materials; isotopes du Re et de l'Os; multi-compteurs d'ions; methode de barbotage; materiaux geochimiques de reference; PLASMA-MASS-SPECTROMETRY; REFERENCE SAMPLES; OSMIUM ISOTOPES; RHENIUM; RATIO; SYSTEMATICS; PRECISE; OS-186/OS-188; SEPARATION; DIGESTION;
D O I
10.1111/j.1751-908X.2011.00125.x
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
A simple, rapid method for the determination of Re and Os concentrations and isotope compositions using isotope dilution multi-collector inductively coupled plasma-mass spectrometry (ID-MC-ICP-MS) combined with Carius tube digestion and sparging introduction of Os was developed. For Os measurement, four channeltron ion counters to detect different Os isotopes were used simultaneously, which led to a drastic reduction in the measurement time. Rhenium isotopes were measured by means of eight Faraday cups with solution nebulisation and an ultrasonic membrane desolvator. The representative 188Os count rate of an Os standard solution containing 50 pg of total Os was approximately 110000120000 cps at the onset of measurement; the Re intensity of our in-house 10 pg g-1 standard solution reached 1820 V/mu g g-1 with a sample uptake rate of 9599 mu l min-1. These values indicate that the sensitivity of the method was sufficient even for samples with low Re and Os concentrations, such as chert. As the temporal variations of the amplification efficiency of the ion counters differed from one another, we adopted a sample-calibrator bracketing method to correct the measured Re and Os isotope ratios. The Re and Os concentrations via the isotope dilution method and the 187Os/188Os ratios of two sedimentary rock reference materials (JMS-2 and JCh-1) on the basis of the isotope ratios determined by the MC-ICP-MS and by negative thermal ionisation mass spectrometry (N-TIMS) were comparable within their ranges. Based on Os isotope measurement of the IAG reference material [Durham Romil Os (DROsS)], the average difference from the recommended value and precision of Os isotope measurements by the sparging method in combination with multi-ion-counters were 0.72% and 0.76% [1RSD (%), n = 29], respectively. The precisions in the 187Os/188Os ratios [1RSD (%)] of JMS-2, JCh-1 and DROsS were 0.350.71, 1.563.31 and 0.991.28%, respectively, which depended on their Os ion intensities. No systematic difference was observed between the Re and Os geochemical compositions of JCh-1 and JMS-2 obtained by means of digestion with inverse aqua regia and CrO3-H2SO4 solutions, suggesting that either acid solution can be used for the sparging method of sedimentary rock samples. As CrO3-H2SO4 solution is believed to liberate predominantly the hydrogenous Re and Os fraction from organic-rich sediment, the sparging method combined with CrO3-H2SO4 digestion and multi-ion-counters in the mass spectrometry is expected to be a powerful tool for reconstructing the secular change in marine Os isotope compositions with high sample throughput.
引用
收藏
页码:131 / 148
页数:18
相关论文
共 50 条
  • [21] A novel chemical purification method for accurate Sn isotope measurement by MC-ICP-MS
    Qu, Qinyuan
    Liu, Wengang
    Zheng, Wang
    Chetelat, Benjamin
    Liu, Qingchuan
    Chen, Jiubin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (09) : 2258 - 2269
  • [22] A common matrix method for precise and accurate isotope ratio measurement by MC-ICP-MS
    Barling, Jane
    Weis, Dominique
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A56 - A56
  • [23] A rapid method of simultaneous chromatographic purification of Li and Mg for isotopic analyses using MC-ICP-MS
    Zhang, Wei
    Tanaka, Ryoji
    Kitagawa, Hiroshi
    Bohlin, Madeleine
    Nakamura, Eizo
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 480
  • [24] Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method
    Li, Jin
    Tang, Suohan
    Zhu, Xiangkun
    Ma, Jianxiong
    Zhao, Xinmiao
    ACTA GEOLOGICA SINICA-ENGLISH EDITION, 2022, 96 (02) : 517 - 524
  • [25] Rapid and Simultaneous Determination Method for Analysis of Minerals in Infant Formula Using ICP-MS
    Fujisaki, Koji
    Fujita, Haruko
    Matsumoto, Hiroshi
    Hashimoto, Koichi
    Kagi, Hiroaki
    FOOD HYGIENE AND SAFETY SCIENCE, 2011, 52 (06): : 336 - 339
  • [26] Accuracy of stable Mg and Ca isotope data obtained by MC-ICP-MS using the standard addition method
    Tipper, Edward T.
    Louvat, Pascale
    Capmas, Francoise
    Galy, Albert
    Gaillardet, Jerome
    CHEMICAL GEOLOGY, 2008, 257 (1-2) : 65 - 75
  • [27] A method for determination of PGE-Re concentrations and Os isotopic compositions in environmental materials
    Zhao, Peipei
    Li, Jie
    Zhong, Lifeng
    Sun, Shengling
    Xu, Jifeng
    ANALYTICAL METHODS, 2014, 6 (15) : 5537 - 5545
  • [28] Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method
    LI Jin
    TANG Suohan
    ZHU Xiangkun
    MA Jianxiong
    ZHAO Xinmiao
    ActaGeologicaSinica(EnglishEdition), 2022, 96 (02) : 517 - 524
  • [29] Isobaric Spike Method for Absolute Isotopic Ratio Determination by MC-ICP-MS
    Shuai, Kang
    Li, Weiqiang
    Hui, Hejiu
    ANALYTICAL CHEMISTRY, 2020, 92 (07) : 4820 - 4828
  • [30] A Method for 87Sr/86Sr Isotope Ratio Determination in Biogenic Apatite by MC-ICP-MS Using the SSB Technique
    Kasyanova, A., V
    Streletskaya, M., V
    Chervyakovskaya, M., V
    Kiseleva, D., V
    PHYSICS, TECHNOLOGIES AND INNOVATION (PTI-2019), 2019, 2174