Combining micro-computed tomography with histology to analyze biomedical implants for peripheral nerve repair

被引:42
|
作者
Hopkins, Tracy M. [1 ]
Heilman, Alexander M. [1 ]
Liggett, James A. [1 ]
LaSance, Kathleen [2 ]
Little, Kevin J. [3 ]
Hom, David B. [4 ]
Minteer, Danielle M. [5 ]
Marra, Kacey G. [5 ,6 ,7 ]
Pixley, Sarah K. [1 ]
机构
[1] Univ Cincinnati, Coll Med, Dept Mol & Cellular Physiol, Cincinnati, OH 45267 USA
[2] Univ Cincinnati, Coll Med, Vontz Core Imaging Lab VCIL, Cincinnati, OH 45267 USA
[3] Cincinnati Childrens Hosp Med Ctr, Div Pediat Orthopaed, Cincinnati, OH 45229 USA
[4] Univ Cincinnati, Coll Med, Div Facial Plast & Reconstruct Surg, Dept Otolatyngol Head & Neck Surg,Facial Paralysi, Cincinnati, OH 45267 USA
[5] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[6] Univ Pittsburgh, Dept Plast Surg, Pittsburgh, PA USA
[7] Univ Pittsburgh, Plast Surg Res Lab, McGowan Inst Regenerat Med, Pittsburgh, PA USA
关键词
Micro-CT; Iodine; Sodium thiosulfate; Lugol's; Immunostaining; Tissue engineering; Peripheral nerve regeneration; Biomedical implants; OF-THE-ART; AXONAL REGENERATION; ADIPOSE-TISSUE; IODINE; CT; VISUALIZATION; THIOSULFATE; SHRINKAGE; SAMPLES; BONE;
D O I
10.1016/j.jneumeth.2015.08.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Biomedical implants used in tissue engineering repairs, such as scaffolds to repair peripheral nerves, can be too large to examine completely with histological `analyses. Micro-computed tomography (micro-CT) with contrast agents allows ex vivo visualization of entire biomaterial implants and their interactions with tissues, but contrast agents can interfere with histological analyses of the tissues or cause shrinkage or loss of antigenicity. New method: Soft tissue, ex vivo micro-CT imaging using Lugol's iodine was compatible with histology after using a rapid (48 h) method of removing iodine. Results: Adult normal and repaired rat sciatic nerves were infiltrated ex vivo with iodine, imaged with micro-CT and then the iodine was removed by incubating tissues in sodium thiosulfate. Subsequent paraffin sections of normal nerve tissues showed no differences in staining with hematoxylin and eosin or immunostaining with multiple antibodies. Iodine treatment and removal did not alter axonal diameter, nuclear size or relative area covered by immunostained axons (p >0.05). Combining imaging modalities allowed comparisons of macroscopic and microscopic features of nerve tissues regenerating through simple nerve conduits or nerve conduits containing a titanium wire for guidance. Comparison with existing methods: Quantification showed that treatment with iodine and sodium thiosulfate did not result in tissue shrinkage or loss of antigenicity. Conclusions: Because this combination of treatments is rapid and does not alter tissue morphology, this expands the ex vivo methods available to examine the success of biomaterial implants used for tissue engineering repairs. Published by Elsevier B.V.
引用
收藏
页码:122 / 130
页数:9
相关论文
共 50 条
  • [41] A Quantitative Volumetric Micro-Computed Tomography Method to Analyze Lung Tumors in Genetically Engineered Mouse Models
    Haines, Brian B.
    Bettano, Kimberly A.
    Chenard, Melissa
    Sevilla, Raquel S.
    Ware, Christopher
    Angagaw, Minilik H.
    Winkelmann, Christopher T.
    Tong, Christopher
    Reilly, John F.
    Sur, Cyrille
    Zhang, Weisheng
    NEOPLASIA, 2009, 11 (01): : 39 - 47
  • [42] Comparisons of the diagnostic accuracies of optical coherence tomography, micro-computed tomography, and histology in periodontal disease: an ex vivo study
    Park, Jin-Young
    Chung, Jung-Ho
    Lee, Jung-Seok
    Kim, Hee-Jin
    Choi, Seong-Ho
    Jung, Ui-Won
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2017, 47 (01): : 30 - 40
  • [43] Combining Structural and Electrochemical Analysis of Electrodes Using Micro-Computed Tomography and a Microfluidic Fuel Cell
    Jhong, Huei-Ru
    Brushett, Fikile R.
    Yin, Leilei
    Stevenson, Darren M.
    Kenis, Paul J. A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2012, 159 (03) : B292 - B298
  • [44] Insight into tableted pellets by combining X-ray micro-computed tomography and experimental compaction
    Boudina, Imen
    Rondet, Eric
    Nezamabadi, Saeid
    Sharkawi, Tahmer
    Powder Technology, 2022, 397
  • [45] Insight into tableted pellets by combining X-ray micro-computed tomography and experimental compaction
    Boudina, Imen
    Rondet, Eric
    Nezamabadi, Saeid
    Sharkawi, Tahmer
    POWDER TECHNOLOGY, 2022, 397
  • [46] Correlations Between Joint Morphology and Pain and Between Magnetic Resonance Imaging, Histology, and Micro-Computed Tomography
    Link, Thomas M.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A : 30 - 32
  • [47] Comparison of the ossification centre images between standard computed tomography and micro-computed tomography
    Wang, W.
    Wang, X.
    Ren, X.
    Chen, L.
    Li, Z.
    Li, X.
    Zhang, P.
    Gao, J.
    Su, B.
    Zhang, S.
    FOLIA MORPHOLOGICA, 2020, 79 (01) : 141 - 147
  • [48] Advantages and limitations of micro-computed tomography and computed tomography imaging of archaeological textiles and coffins
    Sanna Lipkin
    Ville-Pauli Karjalainen
    Hanna-Leena Puolakka
    Mikko A. J. Finnilä
    Heritage Science, 11
  • [49] Advantages and limitations of micro-computed tomography and computed tomography imaging of archaeological textiles and coffins
    Lipkin, Sanna
    Karjalainen, Ville-Pauli
    Puolakka, Hanna-Leena
    Finnila, Mikko A. J.
    HERITAGE SCIENCE, 2023, 11 (01)
  • [50] Quantification of porosity, connectivity and material density of calcium phosphate ceramic implants using micro-computed tomography
    Yeung, Hiu-Yan
    Qin, Ling
    Lee, Kwong-Man
    Leung, Lwok-Sui
    Cheng, Jack Chun-Yiu
    ADVANCED BIOIMAGING TECHNOLOGIES IN ASSESSMENT OF THE QUALITY OF BONE AND SCAFFOLD MATERIALS: TECHNIQUES AND APPLICATIONS, 2007, : 289 - +