Combining micro-computed tomography with histology to analyze biomedical implants for peripheral nerve repair

被引:42
|
作者
Hopkins, Tracy M. [1 ]
Heilman, Alexander M. [1 ]
Liggett, James A. [1 ]
LaSance, Kathleen [2 ]
Little, Kevin J. [3 ]
Hom, David B. [4 ]
Minteer, Danielle M. [5 ]
Marra, Kacey G. [5 ,6 ,7 ]
Pixley, Sarah K. [1 ]
机构
[1] Univ Cincinnati, Coll Med, Dept Mol & Cellular Physiol, Cincinnati, OH 45267 USA
[2] Univ Cincinnati, Coll Med, Vontz Core Imaging Lab VCIL, Cincinnati, OH 45267 USA
[3] Cincinnati Childrens Hosp Med Ctr, Div Pediat Orthopaed, Cincinnati, OH 45229 USA
[4] Univ Cincinnati, Coll Med, Div Facial Plast & Reconstruct Surg, Dept Otolatyngol Head & Neck Surg,Facial Paralysi, Cincinnati, OH 45267 USA
[5] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[6] Univ Pittsburgh, Dept Plast Surg, Pittsburgh, PA USA
[7] Univ Pittsburgh, Plast Surg Res Lab, McGowan Inst Regenerat Med, Pittsburgh, PA USA
关键词
Micro-CT; Iodine; Sodium thiosulfate; Lugol's; Immunostaining; Tissue engineering; Peripheral nerve regeneration; Biomedical implants; OF-THE-ART; AXONAL REGENERATION; ADIPOSE-TISSUE; IODINE; CT; VISUALIZATION; THIOSULFATE; SHRINKAGE; SAMPLES; BONE;
D O I
10.1016/j.jneumeth.2015.08.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Biomedical implants used in tissue engineering repairs, such as scaffolds to repair peripheral nerves, can be too large to examine completely with histological `analyses. Micro-computed tomography (micro-CT) with contrast agents allows ex vivo visualization of entire biomaterial implants and their interactions with tissues, but contrast agents can interfere with histological analyses of the tissues or cause shrinkage or loss of antigenicity. New method: Soft tissue, ex vivo micro-CT imaging using Lugol's iodine was compatible with histology after using a rapid (48 h) method of removing iodine. Results: Adult normal and repaired rat sciatic nerves were infiltrated ex vivo with iodine, imaged with micro-CT and then the iodine was removed by incubating tissues in sodium thiosulfate. Subsequent paraffin sections of normal nerve tissues showed no differences in staining with hematoxylin and eosin or immunostaining with multiple antibodies. Iodine treatment and removal did not alter axonal diameter, nuclear size or relative area covered by immunostained axons (p >0.05). Combining imaging modalities allowed comparisons of macroscopic and microscopic features of nerve tissues regenerating through simple nerve conduits or nerve conduits containing a titanium wire for guidance. Comparison with existing methods: Quantification showed that treatment with iodine and sodium thiosulfate did not result in tissue shrinkage or loss of antigenicity. Conclusions: Because this combination of treatments is rapid and does not alter tissue morphology, this expands the ex vivo methods available to examine the success of biomaterial implants used for tissue engineering repairs. Published by Elsevier B.V.
引用
收藏
页码:122 / 130
页数:9
相关论文
共 50 条
  • [31] A new device for improving dental implants anchorage: a histological and micro-computed tomography study in the rabbit
    Barak, Shlomo
    Neuman, Moshe
    Iezzi, Giovanna
    Piattelli, Adriano
    Perrotti, Vittoria
    Gabet, Yankel
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (08) : 935 - 942
  • [32] Utilizing micro-computed tomography to evaluate bone structure surrounding dental implants: A comparison with histomorphometry
    Vandeweghe, Stefan
    Coelho, Paulo G.
    Vanhove, Christian
    Wennerberg, Ann
    Jimbo, Ryo
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101 (07) : 1259 - 1266
  • [33] Characterization of the porous structures of the green body and sintered biomedical titanium scaffolds with micro-computed tomography
    Arifvianto, B.
    Leeflang, M. A.
    Zhou, J.
    MATERIALS CHARACTERIZATION, 2016, 121 : 48 - 60
  • [34] Definition of the Region of Interest for the Assessment of Alveolar Bone Repair Using Micro-computed Tomography
    Borges, Juliana Simeao
    Costa, Vitor Cardoso
    Irie, Milena Suemi
    de Rezende Barbosa, Gabriella Lopes
    Spin-Neto, Rubens
    Ferreira Soares, Priscilla Barbosa
    JOURNAL OF DIGITAL IMAGING, 2023, 36 (01) : 356 - 364
  • [35] Contrast-Enhanced Micro-Computed Tomography in Evaluation of Spontaneous Repair of Equine Cartilage
    Kulmala, K. A. M.
    Pulkkinen, H. J.
    Rieppo, L.
    Tiitu, V.
    Kiviranta, I.
    Brunott, A.
    Brommer, H.
    van Weeren, R.
    Brama, P. A. J.
    Mikkola, M. T.
    Korhonen, R. K.
    Jurvelin, J. S.
    Toyras, J.
    CARTILAGE, 2012, 3 (03) : 235 - 244
  • [36] Definition of the Region of Interest for the Assessment of Alveolar Bone Repair Using Micro-computed Tomography
    Juliana Simeão Borges
    Vitor Cardoso Costa
    Milena Suemi Irie
    Gabriella Lopes de Rezende Barbosa
    Rubens Spin-Neto
    Priscilla Barbosa Ferreira Soares
    Journal of Digital Imaging, 2023, 36 : 356 - 364
  • [37] Patterns of Diabetic Periodontal Wound Repair: A Study Using Micro-Computed Tomography and Immunohistochemistry
    Chang, Po-Chun
    Chung, Min-Chun
    Wang, Yi-Ping
    Chien, Li-Ying
    Lim, Jason C.
    Liang, Kaicheng
    Chong, Li Yen
    Kuo, Yen-Ping
    Chen, Chun-Hao
    Chiang, Huan-Ching
    JOURNAL OF PERIODONTOLOGY, 2012, 83 (05) : 644 - 652
  • [38] Contours modeling of fascicular groups from micro-computed tomography images of peripheral nerves
    Zhong, Yingchun
    Qi, Jian
    Li, Fang
    Sun, Siyu
    Zhu, Shuang
    Wang, Chao
    Luo, Peng
    MICROSCOPY RESEARCH AND TECHNIQUE, 2021, 84 (12) : 2811 - 2819
  • [39] Evaluating Microelectrode Arrays in Peripheral Nerve Using Micro Computed Tomography
    Frederick, Rebecca A.
    Margolis, Ryan
    Hoyt, Kenneth
    Cogan, Stuart F.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 3432 - 3435
  • [40] X-ray Micro-Computed Tomography: An Emerging Technology to Analyze Vascular Calcification in Animal Models
    Borland, Samantha J.
    Behnsen, Julia
    Ashton, Nick
    Francis, Sheila E.
    Brennan, Keith
    Sherratt, Michael J.
    Withers, Philip J.
    Canfield, Ann E.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (12) : 1 - 27