Combining micro-computed tomography with histology to analyze biomedical implants for peripheral nerve repair

被引:42
|
作者
Hopkins, Tracy M. [1 ]
Heilman, Alexander M. [1 ]
Liggett, James A. [1 ]
LaSance, Kathleen [2 ]
Little, Kevin J. [3 ]
Hom, David B. [4 ]
Minteer, Danielle M. [5 ]
Marra, Kacey G. [5 ,6 ,7 ]
Pixley, Sarah K. [1 ]
机构
[1] Univ Cincinnati, Coll Med, Dept Mol & Cellular Physiol, Cincinnati, OH 45267 USA
[2] Univ Cincinnati, Coll Med, Vontz Core Imaging Lab VCIL, Cincinnati, OH 45267 USA
[3] Cincinnati Childrens Hosp Med Ctr, Div Pediat Orthopaed, Cincinnati, OH 45229 USA
[4] Univ Cincinnati, Coll Med, Div Facial Plast & Reconstruct Surg, Dept Otolatyngol Head & Neck Surg,Facial Paralysi, Cincinnati, OH 45267 USA
[5] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[6] Univ Pittsburgh, Dept Plast Surg, Pittsburgh, PA USA
[7] Univ Pittsburgh, Plast Surg Res Lab, McGowan Inst Regenerat Med, Pittsburgh, PA USA
关键词
Micro-CT; Iodine; Sodium thiosulfate; Lugol's; Immunostaining; Tissue engineering; Peripheral nerve regeneration; Biomedical implants; OF-THE-ART; AXONAL REGENERATION; ADIPOSE-TISSUE; IODINE; CT; VISUALIZATION; THIOSULFATE; SHRINKAGE; SAMPLES; BONE;
D O I
10.1016/j.jneumeth.2015.08.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Biomedical implants used in tissue engineering repairs, such as scaffolds to repair peripheral nerves, can be too large to examine completely with histological `analyses. Micro-computed tomography (micro-CT) with contrast agents allows ex vivo visualization of entire biomaterial implants and their interactions with tissues, but contrast agents can interfere with histological analyses of the tissues or cause shrinkage or loss of antigenicity. New method: Soft tissue, ex vivo micro-CT imaging using Lugol's iodine was compatible with histology after using a rapid (48 h) method of removing iodine. Results: Adult normal and repaired rat sciatic nerves were infiltrated ex vivo with iodine, imaged with micro-CT and then the iodine was removed by incubating tissues in sodium thiosulfate. Subsequent paraffin sections of normal nerve tissues showed no differences in staining with hematoxylin and eosin or immunostaining with multiple antibodies. Iodine treatment and removal did not alter axonal diameter, nuclear size or relative area covered by immunostained axons (p >0.05). Combining imaging modalities allowed comparisons of macroscopic and microscopic features of nerve tissues regenerating through simple nerve conduits or nerve conduits containing a titanium wire for guidance. Comparison with existing methods: Quantification showed that treatment with iodine and sodium thiosulfate did not result in tissue shrinkage or loss of antigenicity. Conclusions: Because this combination of treatments is rapid and does not alter tissue morphology, this expands the ex vivo methods available to examine the success of biomaterial implants used for tissue engineering repairs. Published by Elsevier B.V.
引用
收藏
页码:122 / 130
页数:9
相关论文
共 50 条
  • [21] Three-dimensional virtual histology of the rat uterus musculature using micro-computed tomography
    Roesler, Mathias W.
    Garrett, Amy S.
    Trew, Mark L.
    Gerneke, Dane
    Amirapu, Satya
    Cheng, Leo K.
    Clark, Alys R.
    JOURNAL OF ANATOMY, 2025, 246 (01) : 134 - 147
  • [22] Iodine-enhanced micro-computed tomography of atherosclerotic plaque morphology complements conventional histology
    Self, Trevor S.
    Ginn-Hedman, Anne-Marie
    Kaulfus, Courtney N.
    Newell-Fugate, Annie E.
    Weeks, Brad R.
    Heaps, Cristine L.
    ATHEROSCLEROSIS, 2020, 313 : 43 - 49
  • [23] Coronary micro-computed tomography angiography in mice
    Sawall, Stefan
    Beckendorf, Jan
    Amato, Carlo
    Maier, Joscha
    Backs, Johannes
    Vande Velde, Greetje
    Kachelriess, Marc
    Kuntz, Jan
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [24] The role of micro-computed tomography in forensic investigations
    Rutty, G. N.
    Brough, A.
    Biggs, M. J. P.
    Robinson, C.
    Lawes, S. D. A.
    Hainsworth, S. V.
    FORENSIC SCIENCE INTERNATIONAL, 2013, 225 (1-3) : 60 - 66
  • [25] Quality control of micro-computed tomography systems
    Eloot, L.
    Buls, N.
    Covens, P.
    Willekens, I.
    Lahoutte, T.
    de Mey, J.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 463 - 467
  • [26] Coronary micro-computed tomography angiography in mice
    Stefan Sawall
    Jan Beckendorf
    Carlo Amato
    Joscha Maier
    Johannes Backs
    Greetje Vande Velde
    Marc Kachelrieß
    Jan Kuntz
    Scientific Reports, 10
  • [27] Micro-computed tomography for analysis of urinary calculi
    Williams, James C., Jr.
    McAteer, James A.
    Evan, Andrew P.
    Lingeman, James E.
    UROLOGICAL RESEARCH, 2010, 38 (06): : 477 - 484
  • [28] Hierarchical structure of bone and micro-computed tomography
    McCreadie, BR
    Goulet, RW
    Feldkamp, LA
    Goldstein, SA
    NONINVASIVE ASSESSMENT OF TRABECULAR BONE ARCHITECTURE AND THE COMPETENCE OF BONE, 2001, 496 : 67 - 83
  • [29] The Nasolabial Fold: A Micro-Computed Tomography Study
    Kwon, Hyun-Jin
    O, Jehoon
    Cho, Tae-Hyeon
    Choi, You-Jin
    Yang, Hun-Mu
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 145 (01) : 71 - 79
  • [30] Micro-computed tomography for analysis of urinary calculi
    James C. Williams
    James A. McAteer
    Andrew P. Evan
    James E. Lingeman
    Urological Research, 2010, 38 : 477 - 484