Combining micro-computed tomography with histology to analyze biomedical implants for peripheral nerve repair

被引:42
|
作者
Hopkins, Tracy M. [1 ]
Heilman, Alexander M. [1 ]
Liggett, James A. [1 ]
LaSance, Kathleen [2 ]
Little, Kevin J. [3 ]
Hom, David B. [4 ]
Minteer, Danielle M. [5 ]
Marra, Kacey G. [5 ,6 ,7 ]
Pixley, Sarah K. [1 ]
机构
[1] Univ Cincinnati, Coll Med, Dept Mol & Cellular Physiol, Cincinnati, OH 45267 USA
[2] Univ Cincinnati, Coll Med, Vontz Core Imaging Lab VCIL, Cincinnati, OH 45267 USA
[3] Cincinnati Childrens Hosp Med Ctr, Div Pediat Orthopaed, Cincinnati, OH 45229 USA
[4] Univ Cincinnati, Coll Med, Div Facial Plast & Reconstruct Surg, Dept Otolatyngol Head & Neck Surg,Facial Paralysi, Cincinnati, OH 45267 USA
[5] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[6] Univ Pittsburgh, Dept Plast Surg, Pittsburgh, PA USA
[7] Univ Pittsburgh, Plast Surg Res Lab, McGowan Inst Regenerat Med, Pittsburgh, PA USA
关键词
Micro-CT; Iodine; Sodium thiosulfate; Lugol's; Immunostaining; Tissue engineering; Peripheral nerve regeneration; Biomedical implants; OF-THE-ART; AXONAL REGENERATION; ADIPOSE-TISSUE; IODINE; CT; VISUALIZATION; THIOSULFATE; SHRINKAGE; SAMPLES; BONE;
D O I
10.1016/j.jneumeth.2015.08.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Biomedical implants used in tissue engineering repairs, such as scaffolds to repair peripheral nerves, can be too large to examine completely with histological `analyses. Micro-computed tomography (micro-CT) with contrast agents allows ex vivo visualization of entire biomaterial implants and their interactions with tissues, but contrast agents can interfere with histological analyses of the tissues or cause shrinkage or loss of antigenicity. New method: Soft tissue, ex vivo micro-CT imaging using Lugol's iodine was compatible with histology after using a rapid (48 h) method of removing iodine. Results: Adult normal and repaired rat sciatic nerves were infiltrated ex vivo with iodine, imaged with micro-CT and then the iodine was removed by incubating tissues in sodium thiosulfate. Subsequent paraffin sections of normal nerve tissues showed no differences in staining with hematoxylin and eosin or immunostaining with multiple antibodies. Iodine treatment and removal did not alter axonal diameter, nuclear size or relative area covered by immunostained axons (p >0.05). Combining imaging modalities allowed comparisons of macroscopic and microscopic features of nerve tissues regenerating through simple nerve conduits or nerve conduits containing a titanium wire for guidance. Comparison with existing methods: Quantification showed that treatment with iodine and sodium thiosulfate did not result in tissue shrinkage or loss of antigenicity. Conclusions: Because this combination of treatments is rapid and does not alter tissue morphology, this expands the ex vivo methods available to examine the success of biomaterial implants used for tissue engineering repairs. Published by Elsevier B.V.
引用
收藏
页码:122 / 130
页数:9
相关论文
共 50 条
  • [11] A study of trabecular bones in ovariectomized goats with micro-computed tomography and peripheral quantitative computed tomography
    Siu, WS
    Qin, L
    Cheung, WH
    Leung, KS
    BONE, 2004, 35 (01) : 21 - 26
  • [12] ADVANCES IN MICRO-COMPUTED TOMOGRAPHY
    Herzen, Julia
    MATERIALS EVALUATION, 2022, 80 (06) : 10 - 12
  • [13] Determining Position of the Inferior Alveolar Nerve via Anatomical Dissection and Micro-Computed Tomography in Preparation for Dental Implants
    Massey, Natalie D.
    Galil, Khadry A.
    Wilson, Timothy D.
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2013, 79
  • [14] Evaluation of Osseointegration of Titanium Alloyed Implants: A Comparison of Micro-computed Tomography and Histomorphometry
    Gabler, Carolin
    Zietz, Carmen
    Bieck, Richard
    Goehler, Rebecca
    Bader, Rainer
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S1132 - S1132
  • [15] Osteogenesis around CaP-coated titanium implants visualized using 3D histology and micro-computed tomography
    Cuijpers, Vincent M. J. I.
    Alghamdi, Hamdan S.
    Van Dijk, Natasja W. M.
    Jaroszewicz, Jakub
    Walboomers, X. Frank
    Jansen, John A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2015, 103 (11) : 3463 - 3473
  • [16] Distribution of calcification in carotid endarterectomy tissues: Comparison of micro-computed tomography imaging with histology
    Ababneh, Bashar
    Rejjal, Loui
    Pokharel, Yashashwi
    Nambi, Vijay
    Wang, Xukui
    Tung, Ching-Hsuan
    Han, Richard I.
    Taylor, Addison A.
    Kougias, Panagiotis
    Lumsden, Alan B.
    Lawrie, Gerald
    Reardon, Michael
    Ballantyne, Christie M.
    Morrisett, Joel D.
    Brunner, Gerd
    VASCULAR MEDICINE, 2014, 19 (05) : 343 - 350
  • [17] Virtual histology uncertainty in synchrotron x-ray micro-computed tomography evaluation
    Lauridsen, T.
    Feidenhans'l, R.
    Pinholt, E. M.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (09) : 1569 - 1575
  • [18] Non-Destructive Testing of Ceramic Knee Implants Using Micro-Computed Tomography
    Trieb, Klemens
    Glinz, Jonathan
    Reiter, Michael
    Kastner, Johann
    Senck, Sascha
    JOURNAL OF ARTHROPLASTY, 2019, 34 (09): : 2111 - 2117
  • [19] Quantitative measures of femoral fracture repair in rats derived by micro-computed tomography
    Nyman, Jeffry S.
    Munoz, Steve
    Jadhav, Satyawan
    Mansour, Alfred
    Yoshii, Toshitaka
    Mundy, Gregory R.
    Gutierrez, Gloria E.
    JOURNAL OF BIOMECHANICS, 2009, 42 (07) : 891 - 897
  • [20] REVISIT TO DENONVILLIERS' FASCIA BASED ON ANATOMICAL STUDY USING MICRO-COMPUTED TOMOGRAPHY AND HISTOLOGY.
    Yang, S.
    Kim, N.
    Kang, J.
    DISEASES OF THE COLON & RECTUM, 2020, 63 (06) : E261 - E261