Comparison of Axxent-Xoft, 192Ir and 60Co high-dose-rate brachytherapy sources for image-guided brachytherapy treatment planning for cervical cancer

被引:11
|
作者
Mobit, P. N. [1 ,2 ]
Packianathan, S. [1 ]
He, R. [1 ]
Yang, C. C. [1 ]
机构
[1] Univ Mississippi, Med Ctr, Dept Radiat Oncol, Jackson, MS 39216 USA
[2] Cameroon Oncol Ctr, Douala, Cameroon
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1052期
关键词
50-KV ELECTRONIC BRACHYTHERAPY; PARAMETERS; CARCINOMA;
D O I
10.1259/bjr.20150010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the dosimetric differences and similarities between treatment plans generated with Axxent-Xoft electronic brachytherapy source (Xoft-EBS), Ir-192 and Co-60 for tandem and ovoids (T&O) applicators. Methods: In this retrospective study, we replanned 10 patients previously treated with 192Ir high-dose-rate brachytherapy. Prescription was 7G x 34 fractions to Point A. For each original plan, we created two additional plans with Xoft-EBS and Co-60. The dose to each organ at risk (OAR) was evaluated in terms of V-35% and V-50%, the percentage volume receiving 35% and 50% of the prescription dose, respectively, and D-2cc, highest dose to a 2cm(3) volume of an OAR. Results: There was no difference between plans generated by Ir-192 and Co-60, but the plans generated using Xoft-EBS showed a reduction of up to 50% in V-35%, V-50% and D-2cc. The volumes of the 200% and 150% isodose lines, however, were 74% and 34% greater than the comparable volumes generated with the Ir-192 source. Point B dose was on average only 16% of the Point A dose for plans generated with Xoft-EBS compared with 30% for plans generated with Ir-192 or Co-60. Conclusion: The Xoft-EBS can potentially replace either Ir-192 or Co-60 in T&O treatments. Xoft-EBS offers either better sparing of the OARs compared with Ir-192 or Co-60 or at least similar sparing. Xoft-EBS-generated plans had higher doses within the target volume than Ir-192-or Co-60-generated ones. Advances in knowledge: This work presents newer knowledge in dosimetric comparison between Xoft-EBS, Ir-192 or Co-60 sources for T&O implants.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate 192Ir brachytherapy sources
    Kaveckyte, Vaiva
    Malusek, Alexandr
    Benmakhlouf, Hamza
    Carlsson, Gudrun Alm
    Tedgren, Asa Carlsson
    MEDICAL PHYSICS, 2018, 45 (01) : 429 - 437
  • [32] Treatment results of image-guided high-dose-rate interstitial brachytherapy for recurrent uterine cancer
    Yoshida, K.
    Yamazaki, H.
    Takenaka, T.
    Kotsuma, T.
    Masui, K.
    Yoshioka, Y.
    Uesugi, Y.
    Shinbo, T.
    Tanaka, E.
    Narumi, Y.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S724 - S724
  • [33] Absolute dose measurements using radiochromic films in 192Ir and 60Co HDR brachytherapy
    Oliver Canamas, Laura
    Jose Rovira-Escutia, Juan
    Vijande-Asenjo, Javier
    Candela-Juan, Cristian
    Gimeno-Olmos, Jose
    Carmen Pujades-Claumarchirant, Ma
    Angel Martinez-Navarro, Jose
    Zaragoza-Carrillo, Antonio
    Garcia-Cases, Francisco
    Ballester-Pallares, Facundo
    Perez-Calatayud, Jose
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S350 - S352
  • [34] Severe Gastrointestinal Complications in the Era of Image-guided High-dose-rate Intracavitary Brachytherapy for Cervical Cancer
    Trifiletti, Daniel M.
    Watkins, W. Tyler
    Duska, Linda
    Libby, Bruce B.
    Showalter, Timothy N.
    CLINICAL THERAPEUTICS, 2015, 37 (01) : 49 - 60
  • [35] A comparison of the biological effective dose of 50-kV electronic brachytherapy with 192Ir high-dose-rate brachytherapy for vaginal cuff irradiation
    Rava, Paul
    Dvorak, Tomas
    Markelewicz, Robert J., Jr.
    Hiatt, Jessica R.
    Sternick, Edward S.
    MacAusland, Stephanie G.
    Huber, Kathryn
    Wazer, David E.
    Hepel, Jaroslaw T.
    BRACHYTHERAPY, 2012, 11 (05) : 402 - 407
  • [36] Assessment of dose uniformity around high dose rate 192Ir and 60Co stepping sources
    Farhood B.
    Ghorbani M.
    Radiological Physics and Technology, 2017, 10 (4) : 454 - 463
  • [37] The value of systematic contouring of the bowel for treatment plan optimization in image-guided cervical cancer high-dose-rate brachytherapy
    Damato, Antonio L.
    Buzurovic, Ivan
    Bhagwat, Mandar S.
    Cormack, Robert A.
    Devlin, Phillip M.
    Friesen, Scott
    Hansen, Jorgen
    Lee, Larissa J.
    Manuel, Matthias M.
    Cho, Linda P.
    O'Farrell, Desmond
    Viswanathan, Akila N.
    BRACHYTHERAPY, 2017, 16 (03) : 579 - 585
  • [38] Image-guided Tandem and Colpostat high dose rate brachytherapy for cervical cancer
    Shah, S.
    Yaparpalvi, R.
    Sharma, R.
    Garg, M.
    Deb, N.
    Spierer, M.
    Hong, L.
    Kalnicki, S.
    Mutyala, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S408 - S408
  • [39] Determination of variation in dosimetric parameters of treatment planning with Co-60 and Ir-192 sources in high dose rate brachytherapy of cervical carcinoma
    Srivastava, Shraddha
    Singh, Navin
    Varghese, Misha
    RADIATION PHYSICS AND CHEMISTRY, 2022, 196
  • [40] A standard graphite calorimeter for dosimetry in brachytherapy with high dose rate 192Ir sources
    Guerra, A. S.
    Loreti, S.
    Pimpinella, M.
    Quini, M.
    D'Arienzo, M.
    Astefanoaei, I.
    Caporali, C.
    Bolzan, C.
    Pagliari, M.
    METROLOGIA, 2012, 49 (05) : S179 - S183