Comparison of Axxent-Xoft, 192Ir and 60Co high-dose-rate brachytherapy sources for image-guided brachytherapy treatment planning for cervical cancer

被引:11
|
作者
Mobit, P. N. [1 ,2 ]
Packianathan, S. [1 ]
He, R. [1 ]
Yang, C. C. [1 ]
机构
[1] Univ Mississippi, Med Ctr, Dept Radiat Oncol, Jackson, MS 39216 USA
[2] Cameroon Oncol Ctr, Douala, Cameroon
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1052期
关键词
50-KV ELECTRONIC BRACHYTHERAPY; PARAMETERS; CARCINOMA;
D O I
10.1259/bjr.20150010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the dosimetric differences and similarities between treatment plans generated with Axxent-Xoft electronic brachytherapy source (Xoft-EBS), Ir-192 and Co-60 for tandem and ovoids (T&O) applicators. Methods: In this retrospective study, we replanned 10 patients previously treated with 192Ir high-dose-rate brachytherapy. Prescription was 7G x 34 fractions to Point A. For each original plan, we created two additional plans with Xoft-EBS and Co-60. The dose to each organ at risk (OAR) was evaluated in terms of V-35% and V-50%, the percentage volume receiving 35% and 50% of the prescription dose, respectively, and D-2cc, highest dose to a 2cm(3) volume of an OAR. Results: There was no difference between plans generated by Ir-192 and Co-60, but the plans generated using Xoft-EBS showed a reduction of up to 50% in V-35%, V-50% and D-2cc. The volumes of the 200% and 150% isodose lines, however, were 74% and 34% greater than the comparable volumes generated with the Ir-192 source. Point B dose was on average only 16% of the Point A dose for plans generated with Xoft-EBS compared with 30% for plans generated with Ir-192 or Co-60. Conclusion: The Xoft-EBS can potentially replace either Ir-192 or Co-60 in T&O treatments. Xoft-EBS offers either better sparing of the OARs compared with Ir-192 or Co-60 or at least similar sparing. Xoft-EBS-generated plans had higher doses within the target volume than Ir-192-or Co-60-generated ones. Advances in knowledge: This work presents newer knowledge in dosimetric comparison between Xoft-EBS, Ir-192 or Co-60 sources for T&O implants.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Quality control of 192Ir High Dose Rate Brachytherapy sources
    Pereira, A
    Pirraco, R
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S136 - S137
  • [22] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Sadeghi, Mahdi
    Taghdiri, Fatemah
    Saidi, Pooneh
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (05) : 324 - 329
  • [23] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Mahdi Sadeghi
    Fatemah Taghdiri
    Pooneh Saidi
    Japanese Journal of Radiology, 2011, 29 : 324 - 329
  • [24] Image-guided high-dose-rate brachytherapy in inoperable endometrial cancer
    Dankulchai, P.
    Petsuksiri, J.
    Chansilpa, Y.
    Hoskin, P. J.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1039):
  • [25] High-dose-rate image-guided interstitial brachytherapy for recurrent cervical adenocarcinoma
    Yoshida, K.
    Yamazaki, H.
    Takenaka, T.
    Kotsuma, T.
    Masui, K.
    Uesugi, Y.
    Shimbo, T.
    Yoshikawa, N.
    Yoshioka, H.
    Yoshioka, Y.
    Tanaka, E.
    Narumi, Y.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S933 - S933
  • [26] Estimation and comparison of integral dose to target and organs at risk in three-dimensional computed tomography image-based treatment planning of carcinoma uterine cervix with two high-dose-rate brachytherapy sources: 60Co and 192Ir
    Yadav, Suresh
    Singh, O. P.
    Choudhary, S.
    Saroj, Dinesh Kumar
    Yogi, Veenita
    Goswami, Brijesh
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (01) : 191 - 197
  • [27] High dose rate 192Ir afterloading brachytherapy for cancer of the vagina
    Kushner, DM
    Fleming, PA
    Kennedy, AW
    Wilkinson, DA
    Lee, E
    Saffle, PA
    BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (910): : 719 - 725
  • [28] Assessing Heterogeneity Effects on Points A, B, and Organs at Risk Doses in High-dose-Rate Brachytherapy for Cervical Cancer - A Comparison of 192Ir and 60Co Sources Using Monte Carlo N-Particle 5
    Sadeghi, Mohammad Hossein
    Sina, Sedigheh
    Meigooni, Ali Soleimani
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (02) : 294 - 303
  • [29] Dose perturbation due to catheter materials in high-dose-rate interstitial 192Ir brachytherapy
    Gaudreault, Mathieu
    Reniers, Brigitte
    Landry, Guillaume
    Verhaegen, Frank
    Beaulieu, Luc
    BRACHYTHERAPY, 2014, 13 (06) : 627 - 631
  • [30] Characterization of microMOSFET detectors for in vivo dosimetry in high-dose-rate brachytherapy with 192Ir
    Ruiz-Arrebola, Samuel
    Fabregat-Borras, Rosa
    Rodriguez, Eduardo
    Fernandez-Montes, Manuel
    Perez-Macho, Mercedes
    Ferri, Maria
    Garcia, Ana
    Cardenal, Juan
    Pacheco, Maria T.
    Anchuelo, Javier
    Tornero-Lopez, Ana M.
    Prada, Pedro J.
    Guirado, Damian
    MEDICAL PHYSICS, 2020, 47 (05) : 2242 - 2253