Ex vivo human bile duct radiofrequency ablation with a bipolar catheter

被引:15
|
作者
Atar, Mustafa [1 ]
Kadayifci, Abdurrahman [1 ,2 ]
Daglilar, Ebubekir [1 ]
Hagen, Catherine [3 ,4 ]
Fernandez-del Castillo, Carlos [5 ]
Brugge, William R. [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Div Gastroenterol, 3-H GI Associates,Zero Emerson Pl,Blossom St, Boston, MA 02114 USA
[2] Reyap Istanbul Hosp, Unit Gastroenterol, Istanbul, Turkey
[3] Harvard Med Sch, Massachusetts Gen Hosp, Dept Pathol, Boston, MA USA
[4] Med Coll Wisconsin, Dept Pathol, Milwaukee, WI 53226 USA
[5] Harvard Med Sch, Massachusetts Gen Hosp, Dept Surg, Boston, MA USA
关键词
Radiofrequency ablation; Biliary tumors; Common bile duct; Pancreas; Bipolar catheter; MALIGNANT BILIARY OBSTRUCTION;
D O I
10.1007/s00464-017-5984-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Management of the primary and secondary tumors of the bile ducts still remains as a major clinical challenge. Radiofrequency (RF) ablation (RFA) of these tumors is feasible but the effect of RF energy on the human common bile duct (CBD) and surrounding tissues has not been investigated. This pilot study aimed to determine the relationship between RF energy and the depth of ablation in the normal human CBD. The study was performed on fresh ex vivo human biliary-pancreatic tissue which had been resected for a pancreatic cyst or mass. The study was conducted within 15 min after resection. A bipolar Habib RFA catheter was placed into the middle of the intact CBD, and three different (5, 7, 10 W) power settings were applied over a 90-s period by an RF generator. Gross and histological examinations were performed. The depth of coagulation necrosis in CBD and the effect of RFA on CBD wall and surrounding pancreas tissue were determined by microscopic examination. The study included eight tissue samples. 5 W power was applied to three sites and RFA caused only focal epithelial necrosis limited to the CBD mucosa. 7 and 10 W were applied to five sites and coagulation necrosis occurred in all cases. Microscopically, necrosis was transmural, involved accessory bile duct glands, and extended to the surrounding pancreatic tissue in four of these cases. Macroscopically, RFA resulted in circumferential white-yellowish color change extending approximately 2 cm of the CBD. Bipolar RF energy application with 5 W resulted in limited ablation on CBD wall. However, 7 and 10 W generated tissue necrosis which extended through the CBD wall and into surrounding pancreas tissue. Endoscopic biliary RFA is an effective technique for local biliary tissue ablation but the use of high energy may injure surrounding tissue.
引用
收藏
页码:2808 / 2813
页数:6
相关论文
共 50 条
  • [21] Histopathology of Bipolar Radiofrequency Ablation in the Human Atrium
    Kasirajan, Vigneshwar
    Sayeed, Sadia
    Filler, Elizabeth
    Knarik, Arkun
    Koneru, Jayanthi N.
    Ellenbogen, Kenneth A.
    ANNALS OF THORACIC SURGERY, 2016, 101 (02): : 638 - 643
  • [22] Bile duct radiofrequency ablation for a residual adenoma after endoscopic papillectomy
    Takeshita, Kotaro
    Hijioka, Susumu
    Maehara, Kosuke
    Maruki, Yuta
    Nagashio, Yoshikuni
    Okusaka, Takuji
    Saito, Yutaka
    ENDOSCOPY, 2023, 55 : E185 - E188
  • [23] Experimental bile duct protection by intraductal cooling during radiofrequency ablation
    Stippel, DL
    Bangard, C
    Kasper, HU
    Fischer, JH
    Hölscher, AH
    Gossmann, A
    BRITISH JOURNAL OF SURGERY, 2005, 92 (07) : 849 - 855
  • [24] NOVEL BALLOON CATHETER-BASED ENDOBILIARY RADIOFREQUENCY ABLATION SYSTEM: AN EX-VIVO EXPERIMENTAL STUDY
    Inoue, Tadahisa
    Ito, Kiyoaki
    Yoneda, Masashi
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB385 - AB385
  • [25] Novel balloon catheter-based endobiliary radiofrequency ablation system: Ex-vivo experimental study
    Inoue, Tadahisa
    Ito, Kiyoaki
    Yoneda, Masashi
    DIGESTIVE ENDOSCOPY, 2020, 32 (06) : 974 - 978
  • [26] The mechanism of silent steam pop during radiofrequency catheter ablation: an ex-vivo porcine heart study
    Nakamura, R.
    Suzuki, S. A.
    Usui, U. M.
    Miyazaki, M. S.
    Sasano, S. T.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [27] Bipolar radiofrequency ablation with 2 x 2 electrodes as a building block for matrix radiofrequency ablation: Ex vivo liver experiments and finite element method modelling
    Mulier, Stefaan
    Jiang, Yansheng
    Jamart, Jacques
    Wang, Chong
    Feng, Yuanbo
    Marchal, Guy
    Michel, Luc
    Ni, Yicheng
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2015, 31 (06) : 649 - 665
  • [28] Comparison of wet radiofrequency ablation with dry radiofrequency ablation and radiofrequency ablation using hypertonic saline preinjection:: Ex vivo bovine liver
    Lee, JM
    Han, JK
    Kim, SH
    Shin, KS
    Lee, JY
    Park, HS
    Hur, H
    Choi, BI
    KOREAN JOURNAL OF RADIOLOGY, 2004, 5 (04) : 258 - 265
  • [29] ARRHYTHMIAS DURING UNIPOLAR AND BIPOLAR RADIOFREQUENCY CATHETER ABLATION IN THE CANINE VENTRICLE
    FRANKLIN, JO
    OEFF, M
    LANGBERG, JJ
    HERRE, JM
    GRIFFIN, JC
    CHIN, MC
    SCHEINMAN, MM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04): : 489 - 489
  • [30] Bipolar Radiofrequency Catheter Ablation for Refractory Ventricular Outflow Tract Arrhythmias
    Teh, Andrew W.
    Reddy, Vivek Y.
    Koruth, Jacob S.
    Miller, Marc A.
    Choudry, Subbarao
    D'Avila, Andre
    Dukkipati, Srinivas R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (10) : 1093 - 1099