Ex vivo human bile duct radiofrequency ablation with a bipolar catheter

被引:15
|
作者
Atar, Mustafa [1 ]
Kadayifci, Abdurrahman [1 ,2 ]
Daglilar, Ebubekir [1 ]
Hagen, Catherine [3 ,4 ]
Fernandez-del Castillo, Carlos [5 ]
Brugge, William R. [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Div Gastroenterol, 3-H GI Associates,Zero Emerson Pl,Blossom St, Boston, MA 02114 USA
[2] Reyap Istanbul Hosp, Unit Gastroenterol, Istanbul, Turkey
[3] Harvard Med Sch, Massachusetts Gen Hosp, Dept Pathol, Boston, MA USA
[4] Med Coll Wisconsin, Dept Pathol, Milwaukee, WI 53226 USA
[5] Harvard Med Sch, Massachusetts Gen Hosp, Dept Surg, Boston, MA USA
关键词
Radiofrequency ablation; Biliary tumors; Common bile duct; Pancreas; Bipolar catheter; MALIGNANT BILIARY OBSTRUCTION;
D O I
10.1007/s00464-017-5984-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
Management of the primary and secondary tumors of the bile ducts still remains as a major clinical challenge. Radiofrequency (RF) ablation (RFA) of these tumors is feasible but the effect of RF energy on the human common bile duct (CBD) and surrounding tissues has not been investigated. This pilot study aimed to determine the relationship between RF energy and the depth of ablation in the normal human CBD. The study was performed on fresh ex vivo human biliary-pancreatic tissue which had been resected for a pancreatic cyst or mass. The study was conducted within 15 min after resection. A bipolar Habib RFA catheter was placed into the middle of the intact CBD, and three different (5, 7, 10 W) power settings were applied over a 90-s period by an RF generator. Gross and histological examinations were performed. The depth of coagulation necrosis in CBD and the effect of RFA on CBD wall and surrounding pancreas tissue were determined by microscopic examination. The study included eight tissue samples. 5 W power was applied to three sites and RFA caused only focal epithelial necrosis limited to the CBD mucosa. 7 and 10 W were applied to five sites and coagulation necrosis occurred in all cases. Microscopically, necrosis was transmural, involved accessory bile duct glands, and extended to the surrounding pancreatic tissue in four of these cases. Macroscopically, RFA resulted in circumferential white-yellowish color change extending approximately 2 cm of the CBD. Bipolar RF energy application with 5 W resulted in limited ablation on CBD wall. However, 7 and 10 W generated tissue necrosis which extended through the CBD wall and into surrounding pancreas tissue. Endoscopic biliary RFA is an effective technique for local biliary tissue ablation but the use of high energy may injure surrounding tissue.
引用
收藏
页码:2808 / 2813
页数:6
相关论文
共 50 条
  • [11] Bipolar Radiofrequency Catheter Ablation for Ventricular Arrhythmias
    Nakajima, Kenzaburo
    Zweiker, David
    Spartalis, Michael
    Zachariah, Donah
    Limite, Luca
    Peretto, Giovanni
    Frontera, Antonio
    Della Bella, Paolo
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2022, 23 (05)
  • [12] Bipolar radiofrequency ablation lesion areas and confluence: An ex vivo study and technical report
    Wondra, Andrew
    Gulhar, Shelly
    Brestle, Mason D.
    Chou, Jiling
    Desai, Mehul J.
    PAIN PRACTICE, 2024, 24 (03) : 489 - 501
  • [13] Fluid-modulated bipolar radiofrequency ablation:: An ex-vivo evaluation study
    Bruners, P.
    Mueller, H.
    Guenther, R. W.
    Schmitz-Rode, T.
    Mahnken, A. H.
    ACTA RADIOLOGICA, 2008, 49 (03) : 258 - 266
  • [14] BIPOLAR CATHETER ABLATION FOR VENTRICULAR TACHYCARDIA IN HUMANS: EX-VIVO DEVELOPMENT AND IN-VIVO EXPERIENCE
    Spears, D. A.
    Sivagangabalan, G.
    Barry, A.
    Farid, T.
    Sevaptsidis, E.
    Masse, S.
    Kusha, M.
    Ha, A.
    Nair, K.
    Downar, E.
    Chauhan, V.
    Harris, L.
    Khan, F.
    Das, M.
    Roshan, J.
    Scott, L.
    Nanthakumar, K.
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (05) : S383 - S383
  • [15] A comparison of microwave ablation and bipolar radiofrequency ablation both with an internally cooled probe: Results in ex vivo and in vivo porcine livers
    Yu, Jie
    Liang, Ping
    Yu, Xiaoling
    Liu, Fangyi
    Chen, Lei
    Wang, Yang
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (01) : 124 - 130
  • [16] No-Touch Radiofrequency Ablation: A Comparison of Switching Bipolar and Switching Monopolar Ablation in Ex Vivo Bovine Liver
    Chang, Won
    Lee, Jeong Min
    Lee, Sang Min
    Han, Joon Koo
    KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (02) : 279 - 288
  • [17] Bile duct injury after radiofrequency ablation of liver tumors
    Mine, N
    Tateishi, R
    Akahane, M
    Kondo, Y
    Yamashiki, N
    Fujishima, T
    Sato, S
    Obi, S
    Teratani, T
    Isayama, H
    Komatsu, Y
    Tada, M
    Shiina, S
    Yoshida, H
    Kawabe, T
    Omata, M
    GASTROENTEROLOGY, 2005, 128 (04) : A454 - A454
  • [18] Use of Bipolar Radiofrequency Catheter Ablation in the Treatment of Cardiac Arrhythmias
    Soucek, Filip
    Starek, Zdenek
    CURRENT CARDIOLOGY REVIEWS, 2018, 14 (03) : 185 - 191
  • [19] Bipolar Radiofrequency Ablation for Nodular Thyroid Disease-Ex Vivo and In Vivo Evaluation of a Dose-Response Relationship
    Holmer, Christoph
    Lehmann, Kai S.
    Knappe, Verena
    Zurbuchen, Urte
    Frericks, Bernd
    Schumann, Thomas
    Buhr, Heinz J.
    Ritz, Joerg-Peter
    JOURNAL OF SURGICAL RESEARCH, 2011, 169 (02) : 234 - 240
  • [20] Bile Duct Patency Maintained after Intraductal Radiofrequency Ablation in a Case of Hepatocellular Cholangiocarcinoma with Bile Duct Invasion
    Han, Sung Yong
    Song, Geun Am
    Kim, Dong Uk
    Baek, Dong Hoon
    Lee, Moon Won
    Kim, Gwang Ha
    CLINICAL ENDOSCOPY, 2018, 51 (02) : 201 - 205