Radiation dose calculations for CT scans with tube current modulation using the approach to equilibrium function

被引:10
|
作者
Li, Xinhua
Zhang, Da
Liu, Bob [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Div Diagnost Imaging Phys, Boston, MA 02114 USA
关键词
computed tomography (CT); dosimetry; tube current modulation; DOSIMETRY; EQUATIONS;
D O I
10.1118/1.4898124
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The approach to equilibrium function has been used previously to calculate the radiation dose to a shift-invariant medium undergoing CT scans with constant tube current [Li, Zhang, and Liu, Med. Phys. 39, 5347-5352 (2012)]. The authors have adapted this method to CT scans with tube current modulation (TCM). Methods: For a scan with variable tube current, the scan range was divided into multiple subscan ranges, each with a nearly constant tube current. Then the dose calculation algorithm presented previously was applied. For a clinical CT scan series that presented tube current per slice, the authors adopted an efficient approach that computed the longitudinal dose distribution for one scan length equal to the slice thickness, which center was at z = 0. The cumulative dose at a specific point was a summation of the contributions from all slices and the overscan. Results: The dose calculations performed for a total of four constant and variable tube current distributions agreed with the published results of Dixon and Boone [Med. Phys. 40, 111920 (14pp.) (2013)]. For an abdomen/pelvis scan of an anthropomorphic phantom (model ATOM 701-B, CIRS, Inc., VA) on a GE Lightspeed Pro 16 scanner with 120 kV, N x T = 20 mm, pitch = 1.375, z axis current modulation (auto mA), and angular current modulation (smart mA), dose measurements were performed using two lines of optically stimulated luminescence dosimeters, one of which was placed near the phantom center and the other on the surface. Dose calculations were performed on the central and peripheral axes of a cylinder containing water, whose cross-sectional mass was about equal to that of the ATOM phantom in its abdominal region, and the results agreed with the measurements within 28.4%. Conclusions: The described method provides an effective approach that takes into account subject size, scan length, and constant or variable tube current to evaluate CT dose to a shift-invariant medium. For a clinical CT scan, dose calculations may be performed with a water-containing cylinder whose cross-sectional mass is equal to that of the subject. This method has the potential to substantially improve evaluations of patient dose from clinical CT scans, compared to CTDIvol, size-specific dose estimate (SSDE), or the dose evaluated for a TCM scan with a constant tube current equal to the average tube current of the TCM scan. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Dose equations for tube current modulation in CT scanning and the interpretation of the associated CTDIvol
    Dixon, Robert L.
    Boone, John M.
    MEDICAL PHYSICS, 2013, 40 (11)
  • [42] Dose reduction in body CT examinations by anatomically adapted tube current modulation
    Bautz, WA
    Heim, I
    Wolf, H
    Kalender, WA
    RADIOLOGY, 1997, 205 : 1399 - 1399
  • [43] Radiation dose reduction to the breast in thoracic CT: Comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current
    Wang, Jia
    Duan, Xinhui
    Christner, Jodie A.
    Leng, Shuai
    Yu, Lifeng
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2011, 38 (11) : 6084 - 6092
  • [44] Effect of Localizer Type and Patient Off-Centering On CT Radiation Dose with Use of Automatic Tube Current Modulation
    Ruan, C.
    Sodickson, A.
    Hamberg, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3656 - 3656
  • [45] Effect of Automatic Tube Current Modulation on Radiation Dose and Image Quality for Low Tube Voltage Multidetector Row CT Angiography: Phantom Study
    Schindera, Sebastian T.
    Nelson, Rendon C.
    Yoshizumi, Terry
    Toncheva, Greta
    Nguyen, Giao
    DeLong, David M.
    Szucs-Farkas, Zsolt
    ACADEMIC RADIOLOGY, 2009, 16 (08) : 997 - 1002
  • [46] Chest CT: Reduction in radiation dose using automated x-ray tube current adjustment
    Mayo, JR
    Hsieh, J
    Whittall, KP
    Coche, EE
    Kim, K
    RADIOLOGY, 1997, 205 : 1442 - 1442
  • [47] Commissioning monoenergetic CT images for optimal proton dose calculations using TwinBeam scans
    Randers, P.
    Fuglsang, M.
    Taasti, V. Trier
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1128 - S1129
  • [48] Extraction of Tube Current Values from DICOM CT Images for Patient Dose Calculations
    Lin, P.
    Kubo, T.
    Krishnapillai, R.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [49] Dose reduction in radiotherapy CT scans: clinical experience using variable tube voltage
    Alomar, Marc
    Mari, Adria
    Gil, Carmen
    Pablo Arias, Juan
    Font, Joan
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3835 - S3837
  • [50] Is It Better to Enter a Volume CT Dose Index Value before or after Scan Range Adjustment for Radiation Dose Optimization of Pediatric Cardiothoracic CT with Tube Current Modulation?
    Goo, Hyun Woo
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (04) : 692 - 703