Radiation dose calculations for CT scans with tube current modulation using the approach to equilibrium function

被引:10
|
作者
Li, Xinhua
Zhang, Da
Liu, Bob [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Div Diagnost Imaging Phys, Boston, MA 02114 USA
关键词
computed tomography (CT); dosimetry; tube current modulation; DOSIMETRY; EQUATIONS;
D O I
10.1118/1.4898124
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The approach to equilibrium function has been used previously to calculate the radiation dose to a shift-invariant medium undergoing CT scans with constant tube current [Li, Zhang, and Liu, Med. Phys. 39, 5347-5352 (2012)]. The authors have adapted this method to CT scans with tube current modulation (TCM). Methods: For a scan with variable tube current, the scan range was divided into multiple subscan ranges, each with a nearly constant tube current. Then the dose calculation algorithm presented previously was applied. For a clinical CT scan series that presented tube current per slice, the authors adopted an efficient approach that computed the longitudinal dose distribution for one scan length equal to the slice thickness, which center was at z = 0. The cumulative dose at a specific point was a summation of the contributions from all slices and the overscan. Results: The dose calculations performed for a total of four constant and variable tube current distributions agreed with the published results of Dixon and Boone [Med. Phys. 40, 111920 (14pp.) (2013)]. For an abdomen/pelvis scan of an anthropomorphic phantom (model ATOM 701-B, CIRS, Inc., VA) on a GE Lightspeed Pro 16 scanner with 120 kV, N x T = 20 mm, pitch = 1.375, z axis current modulation (auto mA), and angular current modulation (smart mA), dose measurements were performed using two lines of optically stimulated luminescence dosimeters, one of which was placed near the phantom center and the other on the surface. Dose calculations were performed on the central and peripheral axes of a cylinder containing water, whose cross-sectional mass was about equal to that of the ATOM phantom in its abdominal region, and the results agreed with the measurements within 28.4%. Conclusions: The described method provides an effective approach that takes into account subject size, scan length, and constant or variable tube current to evaluate CT dose to a shift-invariant medium. For a clinical CT scan, dose calculations may be performed with a water-containing cylinder whose cross-sectional mass is equal to that of the subject. This method has the potential to substantially improve evaluations of patient dose from clinical CT scans, compared to CTDIvol, size-specific dose estimate (SSDE), or the dose evaluated for a TCM scan with a constant tube current equal to the average tube current of the TCM scan. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Patient Dose Monitoring in CT with Tube Current Modulation and Multiple Series
    Boone, J.
    Dixon, R.
    Li, B.
    Zhang, D.
    Li, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E374 - E374
  • [22] Dose reduction in multidetector CT using attenuation-based online tube current modulation
    Tack, D
    De Maertelaer, V
    Gevenois, PA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) : 331 - 334
  • [23] Reducing CT Dose During Routine Brain CT Using Attenuation Based Tube Current Modulation (TCM)
    Angel, E.
    Zhang, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3925 - 3925
  • [24] Effect of CT Scan Parameters on Adult and Pediatric CT Dose When Using Automatic Tube Current Modulation
    Winslow, J.
    Kappadath, S.
    MEDICAL PHYSICS, 2010, 37 (06) : 3102 - +
  • [25] Effect of tube current modulation for dose estimation using a simulation tool on body CT examination
    Kawaguchi, Ai
    Matsunaga, Yuta
    Kobayashi, Masanao
    Suzuki, Shoichi
    Matsubara, Kosuke
    Chida, Koichi
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (04) : 562 - 568
  • [26] Pediatric chest MDCT using tube current modulation: Effect on radiation dose with breast shielding
    Coursey, Courtney
    Frush, Donald P.
    Yoshizumi, Terry
    Toncheva, Greta
    Nguyen, Giao
    Greenberg, S. Bruce
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (01) : W54 - W61
  • [27] Calculation of scan length and size-specific dose at longitudinal positions of body CT scans using dose equilibrium function
    Li, Xinhua
    Marschall, Theodore A.
    Yang, Kai
    Liu, Bob
    MEDICAL PHYSICS, 2023, 50 (02) : 1096 - 1104
  • [28] Radiation dose reduction to the eye lens in head CT using tungsten functional paper and organ-based tube current modulation
    Kosaka, Hiroyuki
    Monzen, Hajime
    Amano, Morikazu
    Tamura, Mikoto
    Hattori, Shota
    Kono, Yuki
    Nishimura, Yasumasa
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 124
  • [29] Scanning beyond anatomic limits of the thorax in chest CT: Findings, radiation dose, and automatic tube current modulation
    Campbell, J
    Kalra, MK
    Rizzo, S
    Maher, MM
    Shepard, JA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (06) : 1525 - 1530
  • [30] Metallic prosthesis: Technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients
    Dalal, T
    Kalra, MK
    Rizzo, SMR
    Schmidt, B
    Suess, C
    Flohr, T
    Blake, MA
    Saini, S
    RADIOLOGY, 2005, 236 (02) : 671 - 675