Optimization of pinhole SPECT calibration

被引:0
|
作者
Bequé, D [1 ]
Nuyts, J [1 ]
Bormans, G [1 ]
Suetens, P [1 ]
Dupont, P [1 ]
机构
[1] Katholieke Univ Leuven, Dept Nucl Med, Louvain, Belgium
关键词
pinhole; geometric calibration; acquisition geometry; SPECT;
D O I
10.1109/NSSMIC.2003.1352366
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Previously, we developed a method to determine the acquisition geometry of a pinhole camera. This information is needed for the correct reconstruction of pinhole SPECT images. The method uses a calibration phantom consisting of three point sources. Their positions in the field of view influence the accuracy of the geometry estimate. This study proposes a specific configuration of point sources with a specific position in the field of view for optimal image reconstruction accuracy. For the proposed calibration setup, inaccuracies of the geometry estimate due to noise in the calibration data, only cause sub-resolution inaccuracies in reconstructed images. Further, the calibration method uses a model of the point source configuration, which is only known with limited accuracy. The study demonstrates however, that, with the proposed calibration setup, the error in reconstructed images is comparable to the error in the phantom model.
引用
收藏
页码:2343 / 2347
页数:5
相关论文
共 50 条
  • [21] PET-based geometrical calibration of a pinhole SPECT add-on for an animal PET scanner
    Deng, Xiao
    Beaudoin, Jean-Francois
    Cadorette, Jules
    Naaman, Charles
    Lecomte, Roger
    Yao, Rutao
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2011 - 2025
  • [22] Optimization of pinhole collimator for small animal SPECT using Monte Carlo simulation
    Song, TY
    Choi, Y
    Chung, YH
    Jung, JH
    Choe, YS
    Lee, KH
    Kim, SE
    Kim, BT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 327 - 332
  • [23] System calibration and statistical image reconstruction for ultra-high resolution stationary pinhole SPECT
    van der Have, Frans
    Vastenhouw, Brendan
    Rentmeester, Mart
    Beekman, Freek J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (07) : 960 - 971
  • [24] Simultaneous geometrical calibration of dual head multi-pinhole SPECT optimized for brain imaging
    Qian, Hua
    Jansen, Floris
    Beque, Dirk
    Seo, Youngho
    Bal, Girish
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [25] Quantitative Accuracy Assessment and Optimization of SPECT Geometrical Calibration
    Ma T.
    Miao Y.
    Yao R.
    Dai T.
    Deng X.
    Tsinghua Science and Technology, 2010, 15 (01) : 96 - 101
  • [26] Quantitative Accuracy Assessment and Optimization of SPECT Geometrical Calibration
    马天予
    缪寅斌
    戴甜甜
    TsinghuaScienceandTechnology, 2010, 15 (01) : 96 - 101
  • [27] Parathyroid detection by Pinhole Spect (PHS)
    Hesse, M.
    Brichand, C.
    Walrand, S.
    Marchal, M.
    Demonceau, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S370 - S370
  • [28] Characterization of pinhole SPECT acquisition geometry
    Bequé, D
    Nuyts, J
    Bormans, G
    Suetens, P
    Dupont, P
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (05) : 599 - 612
  • [29] A simplified geometric calibration method for rotating triple head pinhole SPECT system using point source
    Kim, Joong Hyun
    Lee, Jae Sung
    Lee, Won Woo
    Kim, Yu Kyeong
    Kim, Sang Eun
    Lee, Dong Soo
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3368 - 3371
  • [30] Parameter Optimization and Effective Imaging Volume Determination of Helical Scan for a Pinhole Animal SPECT
    Yao, Rutao
    Deng, Xiao
    Dai, Tiantian
    Wei, Qingyang
    Beaudoin, Jean-Francois
    Naaman, Charles
    Ma, Tianyu
    Cadorette, Jules
    Lecomte, Roger
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3797 - 3803