Optimization of pinhole SPECT calibration

被引:0
|
作者
Bequé, D [1 ]
Nuyts, J [1 ]
Bormans, G [1 ]
Suetens, P [1 ]
Dupont, P [1 ]
机构
[1] Katholieke Univ Leuven, Dept Nucl Med, Louvain, Belgium
关键词
pinhole; geometric calibration; acquisition geometry; SPECT;
D O I
10.1109/NSSMIC.2003.1352366
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Previously, we developed a method to determine the acquisition geometry of a pinhole camera. This information is needed for the correct reconstruction of pinhole SPECT images. The method uses a calibration phantom consisting of three point sources. Their positions in the field of view influence the accuracy of the geometry estimate. This study proposes a specific configuration of point sources with a specific position in the field of view for optimal image reconstruction accuracy. For the proposed calibration setup, inaccuracies of the geometry estimate due to noise in the calibration data, only cause sub-resolution inaccuracies in reconstructed images. Further, the calibration method uses a model of the point source configuration, which is only known with limited accuracy. The study demonstrates however, that, with the proposed calibration setup, the error in reconstructed images is comparable to the error in the phantom model.
引用
收藏
页码:2343 / 2347
页数:5
相关论文
共 50 条
  • [41] Geometric Sensitivity of Variable Pinhole SPECT with a Keel-edge Pinhole Model
    Hyemi Cha
    Young-Jun Jung
    Kisung Lee
    Hakjae Lee
    Seungbin Bae
    Jaekeon Bae
    Journal of the Korean Physical Society, 2019, 74 : 318 - 323
  • [42] Geometrical Calibration of a PET-scanner-based Multi-pinhole SPECT Using LYSO Background Radiation
    Wei, Qingyang
    Wang, Shi
    Dai, Tiantian
    Ma, Tianyu
    Liu, Hui
    Wu, Jing
    Jiang, Nianming
    Wu, Zhaoxia
    Liu, Yaqiang
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [43] Optimization of multi-pinhole SPECT imaging for measuring quantitative cerebral blood flow in rats
    Zeniya, Tsutomu
    Kawashima, Hidekazu
    Fukuda, Hajime
    Hashikawa, Yoshiko
    Koshino, Kazuhiro
    Hirano, Yoshiyuki
    Hori, Yuuki
    Miyake, Yoshinori
    Iida, Hidehiro
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [44] System Calibration for FastSPECT III: An Ultra-High Resolution CCD-Based Pinhole SPECT System
    Han, Ling
    Caucci, Luca
    Miller, Brian W.
    Barrett, Harrison H.
    Woolfenden, James M.
    Furenlid, Lars R.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [45] Modeling of Pixelated Detector in SPECT Pinhole Reconstruction
    Feng, Bing
    Zeng, Gengsheng L.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [46] Evaluation of multiplexing in multi-pinhole SPECT
    Jorgensen, Aaron K.
    Zeng, Gengsheng L.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2213 - 2217
  • [47] Modeling of Pixelated Detector in SPECT Pinhole Reconstruction
    Feng, Bing
    Zeng, Gengsheng L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (02) : 888 - 893
  • [48] Distorted pinhole camera modeling and calibration
    Juarez-Salazar, Rigoberto
    Zheng, Juan
    Diaz-Ramirez, Victor H.
    APPLIED OPTICS, 2020, 59 (36) : 11310 - 11318
  • [49] Clinical interest of the pinhole SPECT in thyroid pathology
    Hesse, M.
    Beersaerts, G.
    Walrand, S.
    Neirinckx, S.
    Demonceau, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S197 - S197
  • [50] Laser alignment system for helical pinhole SPECT
    Metzler, SD
    Greer, KL
    Jaszczak, RJ
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1860 - 1864