Optimization of pinhole SPECT calibration

被引:0
|
作者
Bequé, D [1 ]
Nuyts, J [1 ]
Bormans, G [1 ]
Suetens, P [1 ]
Dupont, P [1 ]
机构
[1] Katholieke Univ Leuven, Dept Nucl Med, Louvain, Belgium
关键词
pinhole; geometric calibration; acquisition geometry; SPECT;
D O I
10.1109/NSSMIC.2003.1352366
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Previously, we developed a method to determine the acquisition geometry of a pinhole camera. This information is needed for the correct reconstruction of pinhole SPECT images. The method uses a calibration phantom consisting of three point sources. Their positions in the field of view influence the accuracy of the geometry estimate. This study proposes a specific configuration of point sources with a specific position in the field of view for optimal image reconstruction accuracy. For the proposed calibration setup, inaccuracies of the geometry estimate due to noise in the calibration data, only cause sub-resolution inaccuracies in reconstructed images. Further, the calibration method uses a model of the point source configuration, which is only known with limited accuracy. The study demonstrates however, that, with the proposed calibration setup, the error in reconstructed images is comparable to the error in the phantom model.
引用
收藏
页码:2343 / 2347
页数:5
相关论文
共 50 条
  • [31] SIMPLE PINHOLE CAMERA CALIBRATION
    DAWSONHOWE, KM
    VERNON, D
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1994, 5 (01) : 1 - 6
  • [32] Thyroid pinhole SPECT in mice using a large rotating gamma camera thanks to refined geometric calibration
    Franken, P. R.
    Darcourt, J.
    Defrise, M.
    Vanhove, C.
    Guglielmi, J.
    Koulibaly, P. M.
    Marsault, R.
    Pourcher, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S388 - S388
  • [33] Investigating pinhole SPECT for wrist imaging
    Sabondjian, Eric
    Wells, R. Glenn
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2218 - 2222
  • [34] Targeted multi-pinhole SPECT
    Branderhorst, Woutjan
    Vastenhouw, Brendan
    van der Have, Frans
    Blezer, Erwin L. A.
    Bleeker, Wim K.
    Beekman, Freek J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (03) : 552 - 561
  • [35] Pinhole SPECT vs. cone-beam SPECT
    Zeng, Gengsheng L.
    MEDICAL BIOMETRICS, PROCEEDINGS, 2007, 4901 : 240 - 247
  • [36] Targeted multi-pinhole SPECT
    Woutjan Branderhorst
    Brendan Vastenhouw
    Frans van der Have
    Erwin L. A. Blezer
    Wim K. Bleeker
    Freek J. Beekman
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 552 - 561
  • [37] Ultra high resolution pinhole SPECT
    Ogawa, K
    Kawade, T
    Nakamura, K
    Kubo, A
    Ichihara, T
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1600 - 1604
  • [38] Intrinsic Uniformity Requirements for Pinhole SPECT
    Seret, Alain
    Bleeser, Frederic
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2006, 34 (01) : 43 - 47
  • [39] Bedside SPECT Imaging with Pinhole Collimation
    Cebula, A.
    Gilland, D.
    Studenski, M.
    MEDICAL PHYSICS, 2010, 37 (06) : 3357 - +
  • [40] Geometric Sensitivity of Variable Pinhole SPECT with a Keel-edge Pinhole Model
    Cha, Hyemi
    Jung, Young-Jun
    Lee, Kisung
    Lee, Hakjae
    Bae, Seungbin
    Bae, Jaekeon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 74 (03) : 318 - 323