Optimization of pinhole SPECT calibration

被引:0
|
作者
Bequé, D [1 ]
Nuyts, J [1 ]
Bormans, G [1 ]
Suetens, P [1 ]
Dupont, P [1 ]
机构
[1] Katholieke Univ Leuven, Dept Nucl Med, Louvain, Belgium
关键词
pinhole; geometric calibration; acquisition geometry; SPECT;
D O I
10.1109/NSSMIC.2003.1352366
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Previously, we developed a method to determine the acquisition geometry of a pinhole camera. This information is needed for the correct reconstruction of pinhole SPECT images. The method uses a calibration phantom consisting of three point sources. Their positions in the field of view influence the accuracy of the geometry estimate. This study proposes a specific configuration of point sources with a specific position in the field of view for optimal image reconstruction accuracy. For the proposed calibration setup, inaccuracies of the geometry estimate due to noise in the calibration data, only cause sub-resolution inaccuracies in reconstructed images. Further, the calibration method uses a model of the point source configuration, which is only known with limited accuracy. The study demonstrates however, that, with the proposed calibration setup, the error in reconstructed images is comparable to the error in the phantom model.
引用
收藏
页码:2343 / 2347
页数:5
相关论文
共 50 条
  • [1] Optimization of geometrical calibration in pinhole SPECT
    Bequé, D
    Nuyts, J
    Suetens, P
    Bormans, G
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (02) : 180 - 190
  • [2] An improved calibration technique for pinhole SPECT
    Bordoni, Emanuela
    Mahmood, Shelan
    Erlandsson, Kjell
    Cullum, Ian
    Hutton, Brian
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [3] Perturbative refinement of the geometric calibration in pinhole SPECT
    Defrise, Michel
    Vanhove, Christian
    Nuyts, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (02) : 204 - 214
  • [4] Simultaneous multi-head calibration for pinhole SPECT
    Metzler, SD
    Jaszczak, RJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 113 - 120
  • [5] Calibration of scintillation cameras and pinhole SPECT Imaging systems
    Chen, YC
    Furenlid, LR
    Wilson, DW
    Barrett, HH
    Small Animal SPECT Imaging, 2005, : 195 - 201
  • [6] Simultaneous multi-head calibration for pinhole SPECT
    Metzler, SD
    Jaszczak, RJ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2947 - 2951
  • [7] Accuracy of auto-calibration for pinhole micro-SPECT
    DiFilippo, Frank P.
    Riffe, Matthew J.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1782 - 1785
  • [8] Selection of point source configuration for multi-pinhole SPECT calibration
    Zhou, Lin
    Vunckx, Kathleen
    Nuyts, Johan
    IEEE Nuclear Science Symposium Conference Record, 2011, : 3622 - 3624
  • [9] Selection of Point Source Configuration for Multi-pinhole SPECT Calibration
    Zhau, Lin
    Vunckx, Kathleen
    Nuyts, Lahan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3622 - 3624
  • [10] A detector response function design in pinhole SPECT including geometrical calibration
    El Bitar, Z.
    Huesman, R. H.
    Boutchko, R.
    Bekaert, Virgile
    Brasse, David
    Gullberg, G. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2395 - 2411