Simultaneous multi-head calibration for pinhole SPECT

被引:11
|
作者
Metzler, SD [1 ]
Jaszczak, RJ
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[3] Duke Univ, Dept Biomed Engn, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
calibration; instrumentation; pinhole; small animal; single photon emission computed tomography; SPECT;
D O I
10.1109/TNS.2005.862978
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pinhole collimation is used as a magnifying geometry to overcome the resolution constraints of the gamma cameras used in SPECT. It is very sensitive to the mechanical position of the aperture relative to the axis of rotation. It is also sensitive to the axial position of the aperture. When one camera head is used, there is no intrinsic reference point for determining the axial mechanical shift. However, when multiple heads are used, the axial origin can be defined as the center of the first aperture. The other apertures can be measured relative to the first. A procedure has been developed for simultaneously calibrating multiple heads by using a single point source in the field of view of all heads. The gantry is rotated through 360 degrees. The centroids are fit using a maximum-likelihood method to an equation that describes the axial and transaxial geometry. The three coordinates of the point source are determined along with the mechanical and electronic shifts in the axial and transaxial directions; the axial mechanical shift of the first aperture is set to zero by definition. Another advantage of multi-head calibration is that a further constraint on the position of the point source is made. We apply the calibration information to a sub-micro disk phantom with 1.6 mm disks.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 50 条
  • [1] Simultaneous multi-head calibration for pinhole SPECT
    Metzler, SD
    Jaszczak, RJ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2947 - 2951
  • [2] Simultaneous geometrical calibration of dual head multi-pinhole SPECT optimized for brain imaging
    Qian, Hua
    Jansen, Floris
    Beque, Dirk
    Seo, Youngho
    Bal, Girish
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [3] Multi-Head Multi-Loss Model Calibration
    Galdran, Adrian
    Verjans, Johan W.
    Carneiro, Gustavo
    Ballester, Miguel A. Gonzalez
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT III, 2023, 14222 : 108 - 117
  • [4] Optimization of pinhole SPECT calibration
    Bequé, D
    Nuyts, J
    Bormans, G
    Suetens, P
    Dupont, P
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2343 - 2347
  • [5] Boresight Calibration of the Aerial Multi-Head Camera System
    Lee, Young-Jin
    Yilmaz, Alper
    EVOLUTIONARY AND BIO-INSPIRED COMPUTATION: THEORY AND APPLICATIONS V, 2011, 8059
  • [6] Detection of motion in SPECT using multi-head data combination
    Pellot-Barakat, C
    Ivanovic, M
    Weber, DA
    Shelton, DK
    Herment, A
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1669 - 1673
  • [7] SENSITIVITY, RESOLUTION AND IMAGE QUALITY WITH A MULTI-HEAD SPECT CAMERA
    FAHEY, FH
    HARKNESS, BA
    KEYES, JW
    MADSEN, MT
    BATTISTI, C
    ZITO, V
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (10) : 1859 - 1863
  • [8] Selection of point source configuration for multi-pinhole SPECT calibration
    Zhou, Lin
    Vunckx, Kathleen
    Nuyts, Johan
    IEEE Nuclear Science Symposium Conference Record, 2011, : 3622 - 3624
  • [9] Selection of Point Source Configuration for Multi-pinhole SPECT Calibration
    Zhau, Lin
    Vunckx, Kathleen
    Nuyts, Lahan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3622 - 3624
  • [10] Geometrical calibration and aperture configuration design in multi-pinhole spect
    Vunckx, K.
    Defrise, M.
    Beque, D.
    Vanhove, C.
    Andreyev, A.
    Nuyts, J.
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1403 - +