Simultaneous multi-head calibration for pinhole SPECT

被引:11
|
作者
Metzler, SD [1 ]
Jaszczak, RJ
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[3] Duke Univ, Dept Biomed Engn, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
calibration; instrumentation; pinhole; small animal; single photon emission computed tomography; SPECT;
D O I
10.1109/TNS.2005.862978
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pinhole collimation is used as a magnifying geometry to overcome the resolution constraints of the gamma cameras used in SPECT. It is very sensitive to the mechanical position of the aperture relative to the axis of rotation. It is also sensitive to the axial position of the aperture. When one camera head is used, there is no intrinsic reference point for determining the axial mechanical shift. However, when multiple heads are used, the axial origin can be defined as the center of the first aperture. The other apertures can be measured relative to the first. A procedure has been developed for simultaneously calibrating multiple heads by using a single point source in the field of view of all heads. The gantry is rotated through 360 degrees. The centroids are fit using a maximum-likelihood method to an equation that describes the axial and transaxial geometry. The three coordinates of the point source are determined along with the mechanical and electronic shifts in the axial and transaxial directions; the axial mechanical shift of the first aperture is set to zero by definition. Another advantage of multi-head calibration is that a further constraint on the position of the point source is made. We apply the calibration information to a sub-micro disk phantom with 1.6 mm disks.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 50 条
  • [21] Targeted multi-pinhole SPECT
    Branderhorst, Woutjan
    Vastenhouw, Brendan
    van der Have, Frans
    Blezer, Erwin L. A.
    Bleeker, Wim K.
    Beekman, Freek J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (03) : 552 - 561
  • [22] Targeted multi-pinhole SPECT
    Woutjan Branderhorst
    Brendan Vastenhouw
    Frans van der Have
    Erwin L. A. Blezer
    Wim K. Bleeker
    Freek J. Beekman
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 552 - 561
  • [23] Calibration of scintillation cameras and pinhole SPECT Imaging systems
    Chen, YC
    Furenlid, LR
    Wilson, DW
    Barrett, HH
    Small Animal SPECT Imaging, 2005, : 195 - 201
  • [24] List Mode Image Reconstruction With a Multi-pinhole Triple Head SPECT System
    Fujishiro, Yohei
    Murata, Kazumi
    Motomura, Nobutoku
    Ogawa, Koichi
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [25] A simplified geometric calibration method for rotating triple head pinhole SPECT system using point source
    Kim, Joong Hyun
    Lee, Jae Sung
    Lee, Won Woo
    Kim, Yu Kyeong
    Kim, Sang Eun
    Lee, Dong Soo
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3368 - 3371
  • [26] Restoration of multi-collimator/multi-head SPECT data via the vector Wiener filter.
    Links, JM
    Prince, JL
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 219P - 219P
  • [27] MULTI-HEAD SEQUENTIAL TRANSDUCERS
    PAUN, G
    REVUE ROUMAINE DE MATHEMATIQUES PURES ET APPLIQUEES, 1981, 26 (09): : 1235 - 1253
  • [28] On the diversity of multi-head attention
    Li, Jian
    Wang, Xing
    Tu, Zhaopeng
    Lyu, Michael R.
    NEUROCOMPUTING, 2021, 454 : 14 - 24
  • [29] ON MULTI-HEAD FINITE AUTOMATA
    ROSENBERG, AL
    IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1966, 10 (05) : 388 - +
  • [30] Evaluation of multiplexing in multi-pinhole SPECT
    Jorgensen, Aaron K.
    Zeng, Gengsheng L.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2213 - 2217