Investigation of sensitivity improvement on passive voltage contrast for defect isolation

被引:5
|
作者
Lee, JC [1 ]
Chen, CH [1 ]
Su, D [1 ]
Chuang, JH [1 ]
机构
[1] Taiwan Semicond Mfg Co Ltd, SBIP, Hsinchu 300, Taiwan
关键词
D O I
10.1016/S0026-2714(02)00216-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the increasing complexity of process technology, device features are now down to the deep-submicron range and the number of metal layers has increased to as many as 9 layers. At the same time, failure analysis (FA) has become significantly more difficult especially fault localization. Many localization tools such as EMMI (combined with Mercury Cadmium Telluride detector), LIVA, TIVA, SEI, OBIRCH, OBIC... etc. are not always precise enough by themselves to pin point defects. However, combining these techniques with layout tracing and passive voltage contrast (PVC) can improve the accuracy of defect isolation and increase the FA hit rate greatly. Passive voltage contrast in SEM or FIB is a well-known technique to identify leaky poly and open nodes (contacts via). However, conventional PVC cannot easily discern problems caused by higher resistance or implant induced faulty nodes. This work describes how to use different techniques, such as increasing emission current, increasing objective aperture, applying stage bias and thinning the substrate from the backside to improve the sensitivity of passive voltage contrast to localize defects. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1707 / 1710
页数:4
相关论文
共 50 条
  • [31] Defect Investigation in Medium-Voltage EPR Cable
    Reid, Alistair J.
    Hu, Xiao
    Judd, Martin D.
    Siew, W. H.
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 323 - 326
  • [32] Strategies for Passive Sensitivity Improvement of NDIR Ethylene Gas Detectors
    Sklorz, Adam
    Lang, Walter
    EUROSENSORS XXV, 2011, 25
  • [33] Dynamic imagery can enhance contrast sensitivity improvement by imagery
    Tanaka, Y.
    Tamori, Y.
    Asakura, N.
    Suzuki, R.
    PERCEPTION, 2009, 38 : 177 - 177
  • [34] Improvement of contrast sensitivity with practice is not compatible with a sensory threshold account
    Solomon, Joshua A.
    Tyler, Christopher W.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2017, 34 (06) : 870 - 880
  • [35] Impaired contrast sensitivity does not reflect nigrostriatal defect in Parkinson disease
    Kotagal, Vikas
    Muller, Martijn
    Albin, Roger
    Koeppe, Robert
    Frey, Kirk
    Bohnen, Nicolaas
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [36] CATHODOLUMINESCENCE CONTRAST OF LOCALIZED DEFECTS .2. DEFECT INVESTIGATION
    PEY, KL
    PHANG, JCH
    CHAN, DSH
    SCANNING MICROSCOPY, 1995, 9 (02) : 367 - 380
  • [37] Electron Beam Inspection: Voltage Contrast Inspection to Characterize Contact Isolation
    Hafer, Richard F.
    Stamper, Andrew
    Hsieh, Jerry
    2020 31ST ANNUAL SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE (ASMC), 2020,
  • [38] Passive voltage contrast technique for rapid in-line characterization and failure isolation during development of deep-submicron ASIC CMOS technology
    Liang, V
    Sur, H
    Bothra, S
    ISTFA '98: PROCEEDINGS OF THE 24TH INTERNATIONAL SYMPOSIUM FOR TESTING AND FAILURE ANALYSIS, 1998, : 221 - 225
  • [39] A PHOTOELECTROCHEMICAL INVESTIGATION OF PASSIVE FILMS FORMED BY ALTERNATING VOLTAGE PASSIVATION
    SCHMUKI, P
    BOHNI, H
    MANSFELD, F
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1993, 140 (07) : L119 - L121
  • [40] Fault Identification by Use of a Simulated Passive Voltage Contrast Reference CAD Display
    Fredrickson, R.
    ISTFA 2006, 2006, : 328 - 333