Investigation of sensitivity improvement on passive voltage contrast for defect isolation

被引:5
|
作者
Lee, JC [1 ]
Chen, CH [1 ]
Su, D [1 ]
Chuang, JH [1 ]
机构
[1] Taiwan Semicond Mfg Co Ltd, SBIP, Hsinchu 300, Taiwan
关键词
D O I
10.1016/S0026-2714(02)00216-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the increasing complexity of process technology, device features are now down to the deep-submicron range and the number of metal layers has increased to as many as 9 layers. At the same time, failure analysis (FA) has become significantly more difficult especially fault localization. Many localization tools such as EMMI (combined with Mercury Cadmium Telluride detector), LIVA, TIVA, SEI, OBIRCH, OBIC... etc. are not always precise enough by themselves to pin point defects. However, combining these techniques with layout tracing and passive voltage contrast (PVC) can improve the accuracy of defect isolation and increase the FA hit rate greatly. Passive voltage contrast in SEM or FIB is a well-known technique to identify leaky poly and open nodes (contacts via). However, conventional PVC cannot easily discern problems caused by higher resistance or implant induced faulty nodes. This work describes how to use different techniques, such as increasing emission current, increasing objective aperture, applying stage bias and thinning the substrate from the backside to improve the sensitivity of passive voltage contrast to localize defects. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1707 / 1710
页数:4
相关论文
共 50 条
  • [41] Circuit Tracing on Integrated Circuit Using FIB Passive Voltage Contrast Effect
    Sorkin, Alexander
    Pawlowicz, Chris
    Krechmer, Alex
    Phaneuf, Michael W.
    ISTFA 2015: CONFERENCE PROCEEDINGS FROM THE 41ST INTERNATIONAL SYMPOSIUM FOR TESTING AND FAILURE ANALYSIS, 2015, : 92 - 96
  • [42] PASSIVE NON-RESONANT TECHNIQUE FOR PULSE CONTRAST ENHANCEMENT AND GAIN ISOLATION
    SALA, K
    RICHARDSON, MC
    JOURNAL OF APPLIED PHYSICS, 1978, 49 (04) : 2268 - 2276
  • [43] Power Distribution Analysis of an Integrated Circuit Using FIB Passive Voltage Contrast
    Sorkin, Alexander
    Pawlowicz, Chris
    Krechmer, Alex
    ISTFA 2016: CONFERENCE PROCEEDINGS FROM THE 42ND INTERNATIONAL SYMPOSIUM FOR TESTING AND FAILURE ANALYSIS, 2016, : 313 - 316
  • [44] Voltage contrast defect inspection of contacts and vias for deep quarter micron devices
    Yamazaki, Y
    Hayashi, H
    Miyoshi, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 (12B): : 7168 - 7172
  • [45] Voltage contrast defect inspection of contacts and vias for deep quarter micron devices
    Yamazaki, Yuichiro
    Hayashi, Hiroyuki
    Miyoshi, Motosuke
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (12 B): : 7168 - 7172
  • [46] Defect Localization and Nanofabrication for Conductive Structures with Voltage Contrast in Helium Ion Microscopy
    Xia, Deying
    McVey, Shawn
    Chuong Huynh
    Kuehn, Wilhelm
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (05) : 5509 - 5516
  • [47] Experimental Investigation on the Sensitivity of an Industrial Process to Voltage Dips
    Weldemariam, L. E.
    Gartner, H. J.
    Cuk, V.
    Cobben, J. F. G.
    Kling, W. L.
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [48] Sensitivity improvement of the receiver module in the passive Tag based RFID reader
    Rhee, Seunghak
    Park, Jongan
    Chun, Jonghun
    UBIQUITOUS INTELLIGENCE AND COMPUTING, PROCEEDINGS, 2007, 4611 : 13 - +
  • [49] Investigation of using passive repeaters for indoor radio coverage improvement
    Huang, Y
    Yi, N
    Zhu, X
    IEEE ANTENNAS AND PROPAGATION SOCIETY SYMPOSIUM, VOLS 1-4 2004, DIGEST, 2004, : 1623 - 1626
  • [50] Equipment for investigation of the electronic devices with the voltage contrast technique in SEM
    Drzazga, W
    Klubinski, G
    Slowko, W
    METAL/NONMETAL MICROSYSTEMS: PHYSICS, TECHNOLOGY, AND APPLICATIONS, 1996, 2780 : 121 - 124