Phase-contrast MR angiography for detection of arteriosclerotic renal artery stenosis

被引:2
|
作者
Duda, SH
Schick, F
Teufl, F
MullerSchimpfle, M
Erley, C
Schneider, W
Miller, S
Claussen, CD
机构
[1] UNIV TUBINGEN,DEPT INTERNAL MED 3,D-72076 TUBINGEN,GERMANY
[2] UNIV TUBINGEN,DEPT CARDIOVASC & THORAC SURG,D-72076 TUBINGEN,GERMANY
关键词
renal arteries; stenosis or obstruction; MR; pulse sequences; phase imaging;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the accuracy of 3-D phase-contrast (PC) MR imaging with a 2-D time-of-flight (TOF) technique in the detection of arteriosclerotic renal artery stenosis. Material and Methods: Twenty-two patients with 28 angiographically proven renal artery stenoses were examined in a prospective blinded fashion by using 2-D TOF MR angiography (MRA) with venous saturation (FLASH) and 3-D PC MRA. The renal arteries were subdivided into 3 segments and graded for the presence of stenoses on a scale of 0-4 by 3 radiologists in blind. Results: The accuracy of TOF and PC imaging in detecting renal artery stenoses was 65% and 77% respectively. Both 2-D TOF and 3-D PC MRA depicted 84% of the stenoses of the proximal renal artery greater than 50% in diameter. Renal artery stenoses greater than 50% and more than 15 mm in distance from the aorta were detected in 40% of cases with the 2-D TOF sequence and in 76% with the 3-D PC technique (p<0.05). The rate of false-negative results was 32%. Conclusion: PC MRA is better at visualizing stenoses in the middle segment of the renal arteries and supplements conventional TOF techniques with additional information. However, even when the two techniques are combined, the false-negative rate in the MR imaging of stenoses of the renal arteries still needs to be reduced.
引用
收藏
页码:287 / 291
页数:5
相关论文
共 50 条
  • [41] Cerebral Venous Thrombosis: Diagnostic Features of Phase-Contrast MR Angiography
    Tulupov, A. A.
    Savelyeva, L. A.
    Bogomyakova, O. B.
    Prygova, Yu A.
    APPLIED MAGNETIC RESONANCE, 2011, 41 (2-4) : 551 - 560
  • [42] Contrast-enhanced MR angiography for evaluation of carotid artery stenosis
    Link, J
    Steffens, JC
    Graessner, J
    Heller, M
    RADIOLOGY, 1996, 201 : 158 - 158
  • [43] A PITFALL IN DETECTION OF INTRACRANIAL UNRUPTURED ANEURYSMS ON 3-DIMENSIONAL PHASE-CONTRAST MR-ANGIOGRAPHY
    ARAKI, Y
    KOHMURA, E
    TSUKAGUCHI, I
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (09) : 1618 - 1623
  • [44] HIGH-VELOCITY FLOW DETECTED WITH PHASE-CONTRAST MR ANGIOGRAPHY BUT NOT WITH TIME-OF-FLIGHT MR ANGIOGRAPHY
    COUSINS, JP
    WAGLE, WA
    ZIRINSKY, K
    DUMOULIN, CL
    RADIOLOGY, 1992, 185 : 203 - 204
  • [45] Renal MR angiography: Current debates and developments in imaging of renal artery stenosis
    Schoenberg, SO
    Rieger, J
    Nittka, M
    Dietrich, O
    Johannson, LO
    Reiser, MF
    SEMINARS IN ULTRASOUND CT AND MRI, 2003, 24 (04) : 255 - 267
  • [46] Caffeine-induced Vascular Reactivity in the Ophthalmic Artery: A Preliminary Study using Phase-contrast MR Angiography
    Park, Chan-A
    Kim, Hang-Keun
    Lee, Yeong-Bae
    Son, Young-Don
    Kang, Chang-Ki
    JOURNAL OF MAGNETICS, 2017, 22 (04) : 557 - 562
  • [47] Assessment of renal artery stenosis by 3-D contrast-enhanced and 3-D phase-contrast magnetic resonance angiography: A comparison with conventional X-ray angiography
    Rozo, JC
    Flamm, S
    Lambert, B
    Lee, VV
    Hernandez, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 323A - 323A
  • [48] An International Multicenter Comparison of Time-SLIP Unenhanced MR Angiography and Contrast-Enhanced CT Angiography for Assessing Renal Artery Stenosis: The Renal Artery Contrast-Free Trial
    Albert, Timothy S. E.
    Akahane, Masaaki
    Parienty, Isabelle
    Yellin, Nancy
    Catala, Violeta
    Alomar, Xavier
    Prot, Antoine
    Tomizawa, Nobuo
    Xue, Huadan
    Katabathina, Venkata S.
    Lopera, Jorge E.
    Jin, Zhengyu
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (01) : 182 - 188
  • [49] Noninvasive analysis of renal artery blood flow dynamics with MR cine phase-contrast flow measurements
    Schoenberg, SO
    Just, A
    Bock, M
    Knopp, MV
    Persson, PB
    Kirchheim, HR
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (05): : H2477 - H2484
  • [50] CORRECTION OF PARTIAL VOLUME INACCURACIES IN QUANTITATIVE PHASE-CONTRAST MR-ANGIOGRAPHY
    HAMILTON, CA
    MAGNETIC RESONANCE IMAGING, 1994, 12 (07) : 1127 - 1130