CORRECTION OF PARTIAL VOLUME INACCURACIES IN QUANTITATIVE PHASE-CONTRAST MR-ANGIOGRAPHY

被引:20
|
作者
HAMILTON, CA
机构
[1] Department of Radiology, MRI Center, The Bowman Gray School of Medicine, Winston-Salem, NC 27157-1022, Medical Center Blvd
关键词
PHASE CONTRAST; PHASE MAPPING; PARTIAL VOLUME; MAGNETIC RESONANCE ANGIOGRAPHY (MRA); QUANTITATIVE VELOCITY MEASUREMENT;
D O I
10.1016/0730-725X(94)91245-R
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The phase difference method of phase contrast MR angiography provides a means of measuring the average velocity in each voxel of an MR scan. When static tissue is present in a voxel containing flow, the measured velocity is not the average velocity of the flow alone, but is lower due to the partial volume effect of the static tissue. We present a preprocessing technique that removes the contribution of static tissue in each voxel prior to calculation of average velocity, resulting in more accurate velocity measurements and better lumen definition. Results of flow tube experiments are presented which confirm the improvement in measurement accuracy.
引用
收藏
页码:1127 / 1130
页数:4
相关论文
共 50 条
  • [1] QUANTITATIVE FLOW MEASUREMENT IN PHASE-CONTRAST MR ANGIOGRAPHY
    WALKER, MF
    SOUZA, SP
    DUMOULIN, CL
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) : 304 - 313
  • [2] PULSATILE INCREASES IN ANEURYSM SIZE DETERMINED BY CINE PHASE-CONTRAST MR-ANGIOGRAPHY
    MEYER, FB
    HUSTON, J
    RIEDERER, SS
    JOURNAL OF NEUROSURGERY, 1993, 78 (06) : 879 - 883
  • [3] 3D PHASE-CONTRAST EPI MR-ANGIOGRAPHY OF THE CAROTID ARTERIES
    WILDERMUTH, S
    DEBATIN, JF
    HUISMAN, TAGM
    LEUNG, DA
    MCKINNON, GC
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (06) : 871 - 878
  • [4] EFFECTS OF INTRAVOXEL VELOCITY DISTRIBUTIONS ON THE ACCURACY OF THE PHASE-MAPPING METHOD IN PHASE-CONTRAST MR-ANGIOGRAPHY
    HAMILTON, CA
    MORAN, PR
    SANTAGO, P
    RAJALA, SA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) : 752 - 755
  • [5] 3-DIMENSIONAL PHASE-CONTRAST MR-ANGIOGRAPHY OF THE RENAL-ARTERIES - COMPARISON WITH AORTOGRAPHY
    GOMES, AS
    YOON, H
    FLAMM, SD
    GOODWIN, SC
    RADIOLOGY, 1995, 197 : 214 - 214
  • [6] THE ROLE OF THE CIRCLE OF WILLIS IN CAROTID OCCLUSION - ASSESSMENT WITH PHASE-CONTRAST MR-ANGIOGRAPHY AND TRANSCRANIAL DUPLEX
    MIRALLES, M
    DOLZ, JL
    COTILLAS, J
    ALDOMA, J
    SANTISO, MA
    GIMENEZ, A
    CAPDEVILA, A
    CAIROLS, MA
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1995, 10 (04) : 424 - 430
  • [7] UPPER ABDOMINAL PHASE-CONTRAST MR-ANGIOGRAPHY - COMPARISON OF CINE AND NON-CINE TECHNIQUES
    BURKART, DJ
    JOHNSON, CD
    RADIOLOGY, 1995, 195 (01) : 101 - 105
  • [8] A PITFALL IN DETECTION OF INTRACRANIAL UNRUPTURED ANEURYSMS ON 3-DIMENSIONAL PHASE-CONTRAST MR-ANGIOGRAPHY
    ARAKI, Y
    KOHMURA, E
    TSUKAGUCHI, I
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (09) : 1618 - 1623
  • [9] CAROTID-ARTERY STENOSIS - CLINICAL EFFICACY OF MR PHASE-CONTRAST FLOW QUANTIFICATION AS AN ADJUNCT TO MR-ANGIOGRAPHY
    VANNINEN, RL
    MANNINEN, HI
    PARTANEN, PLK
    VAINIO, PA
    SOIMAKALLIO, S
    RADIOLOGY, 1995, 194 (02) : 459 - 467
  • [10] EVALUATION OF THE PORTAL VENOUS SYSTEM BEFORE LIVER-TRANSPLANTATION - VALUE OF PHASE-CONTRAST MR-ANGIOGRAPHY
    NGHIEM, HV
    WINTER, TC
    MOUNTFORD, MC
    MACK, LA
    YUAN, C
    COLDWELL, DM
    ALTHAUS, SJ
    CARITHERS, RL
    MCVICAR, JP
    FREENY, PC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (04) : 871 - 878