Phase-contrast MR angiography for detection of arteriosclerotic renal artery stenosis

被引:2
|
作者
Duda, SH
Schick, F
Teufl, F
MullerSchimpfle, M
Erley, C
Schneider, W
Miller, S
Claussen, CD
机构
[1] UNIV TUBINGEN,DEPT INTERNAL MED 3,D-72076 TUBINGEN,GERMANY
[2] UNIV TUBINGEN,DEPT CARDIOVASC & THORAC SURG,D-72076 TUBINGEN,GERMANY
关键词
renal arteries; stenosis or obstruction; MR; pulse sequences; phase imaging;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the accuracy of 3-D phase-contrast (PC) MR imaging with a 2-D time-of-flight (TOF) technique in the detection of arteriosclerotic renal artery stenosis. Material and Methods: Twenty-two patients with 28 angiographically proven renal artery stenoses were examined in a prospective blinded fashion by using 2-D TOF MR angiography (MRA) with venous saturation (FLASH) and 3-D PC MRA. The renal arteries were subdivided into 3 segments and graded for the presence of stenoses on a scale of 0-4 by 3 radiologists in blind. Results: The accuracy of TOF and PC imaging in detecting renal artery stenoses was 65% and 77% respectively. Both 2-D TOF and 3-D PC MRA depicted 84% of the stenoses of the proximal renal artery greater than 50% in diameter. Renal artery stenoses greater than 50% and more than 15 mm in distance from the aorta were detected in 40% of cases with the 2-D TOF sequence and in 76% with the 3-D PC technique (p<0.05). The rate of false-negative results was 32%. Conclusion: PC MRA is better at visualizing stenoses in the middle segment of the renal arteries and supplements conventional TOF techniques with additional information. However, even when the two techniques are combined, the false-negative rate in the MR imaging of stenoses of the renal arteries still needs to be reduced.
引用
收藏
页码:287 / 291
页数:5
相关论文
共 50 条
  • [31] Noninvasive Detection of Vertebral Artery Stenosis A Comparison of Contrast-Enhanced MR Angiography, CT Angiography, and Ultrasound
    Khan, Sofia
    Rich, Philip
    Clifton, Andrew
    Markus, Hugh S.
    STROKE, 2009, 40 (11) : 3499 - 3503
  • [32] Renal artery stenosis: Evaluation with breath-hold, three-dimensional, dynamic, gadolinium-enhanced versus three-dimensional, phase-contrast MR angiography
    DeCobelli, F
    Vanzulli, A
    Sironi, S
    Mellone, R
    Angeli, E
    Venturini, M
    Garancini, MP
    Quartagno, R
    Bianchi, G
    DelMaschio, A
    RADIOLOGY, 1997, 205 (03) : 689 - 695
  • [33] Breath-hold 3D dynamic single-dose gadolinium-enhanced MR angiography (MRA) versus 3D phase-contrast MR angiography in evaluation of renal artery stenosis
    DeCobelli, F
    Vanzulli, A
    Sironi, S
    Angeli, E
    Venturini, M
    DelMaschio, A
    RADIOLOGY, 1997, 205 : 272 - 272
  • [34] LIVER METASTASES - DETECTION BY PHASE-CONTRAST MR IMAGING
    STARK, DD
    WITTENBERG, J
    MIDDLETON, MS
    FERRUCCI, JT
    RADIOLOGY, 1986, 158 (02) : 327 - 332
  • [35] Phase-contrast MR angiography of peripheral arteries: technique and clinical application
    P. Reimer
    M. Boos
    European Radiology, 1999, 9 : 122 - 127
  • [36] Phase-contrast MR angiography of peripheral arteries: technique and clinical application
    Reimer, P
    Boos, M
    EUROPEAN RADIOLOGY, 1999, 9 (01) : 122 - 127
  • [37] Coarctation of the aorta: Collateral flow assessment with phase-contrast MR angiography
    Julsrud, PR
    Breen, JF
    Felmlee, JP
    Warnes, CA
    Connolly, HM
    Schaff, HV
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (06) : 1735 - 1742
  • [38] 3-DIMENSIONAL PHASE-CONTRAST MR-ANGIOGRAPHY OF THE RENAL-ARTERIES - COMPARISON WITH AORTOGRAPHY
    GOMES, AS
    YOON, H
    FLAMM, SD
    GOODWIN, SC
    RADIOLOGY, 1995, 197 : 214 - 214
  • [39] Cerebral Venous Thrombosis: Diagnostic Features of Phase-Contrast MR Angiography
    A. A. Tulupov
    L. A. Savelyeva
    O. B. Bogomyakova
    Yu. A. Prygova
    Applied Magnetic Resonance, 2011, 41 : 551 - 560
  • [40] PHASE-CONTRAST CINE MR ANGIOGRAPHY IN CHRONIC LIVER-DISEASE
    BURKART, DJ
    JOHNSON, CD
    MORTON, MJ
    EHMAN, RL
    RADIOLOGY, 1993, 187 (02) : 407 - 412