Phase-contrast MR angiography for detection of arteriosclerotic renal artery stenosis

被引:2
|
作者
Duda, SH
Schick, F
Teufl, F
MullerSchimpfle, M
Erley, C
Schneider, W
Miller, S
Claussen, CD
机构
[1] UNIV TUBINGEN,DEPT INTERNAL MED 3,D-72076 TUBINGEN,GERMANY
[2] UNIV TUBINGEN,DEPT CARDIOVASC & THORAC SURG,D-72076 TUBINGEN,GERMANY
关键词
renal arteries; stenosis or obstruction; MR; pulse sequences; phase imaging;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the accuracy of 3-D phase-contrast (PC) MR imaging with a 2-D time-of-flight (TOF) technique in the detection of arteriosclerotic renal artery stenosis. Material and Methods: Twenty-two patients with 28 angiographically proven renal artery stenoses were examined in a prospective blinded fashion by using 2-D TOF MR angiography (MRA) with venous saturation (FLASH) and 3-D PC MRA. The renal arteries were subdivided into 3 segments and graded for the presence of stenoses on a scale of 0-4 by 3 radiologists in blind. Results: The accuracy of TOF and PC imaging in detecting renal artery stenoses was 65% and 77% respectively. Both 2-D TOF and 3-D PC MRA depicted 84% of the stenoses of the proximal renal artery greater than 50% in diameter. Renal artery stenoses greater than 50% and more than 15 mm in distance from the aorta were detected in 40% of cases with the 2-D TOF sequence and in 76% with the 3-D PC technique (p<0.05). The rate of false-negative results was 32%. Conclusion: PC MRA is better at visualizing stenoses in the middle segment of the renal arteries and supplements conventional TOF techniques with additional information. However, even when the two techniques are combined, the false-negative rate in the MR imaging of stenoses of the renal arteries still needs to be reduced.
引用
收藏
页码:287 / 291
页数:5
相关论文
共 50 条
  • [21] Contrast-enhanced MR angiography utilizing parallel acquisition techniques in renal artery stenosis detection
    Slanina, Martin
    Zizka, Jan
    Klzo, Ludovit
    Lojik, Miroslav
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (01) : E46 - E50
  • [22] QUANTITATIVE FLOW MEASUREMENT IN PHASE-CONTRAST MR ANGIOGRAPHY
    WALKER, MF
    SOUZA, SP
    DUMOULIN, CL
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) : 304 - 313
  • [23] Poststenotic signal attenuation on 3 D phase-contrast MR angiography: a useful finding in haemodynamically significant carotid artery stenosis
    T. Iseda
    S. Nakano
    D. Miyahara
    S. Uchinokura
    T. Goya
    S. Wakisaka
    Neuroradiology, 2000, 42 : 868 - 873
  • [24] Poststenotic signal attenuation on 3D phase-contrast MR angiography: a useful finding in haemodynamically significant carotid artery stenosis
    Iseda, T
    Nakano, S
    Miyahara, D
    Uchinokura, S
    Goya, T
    Wakisaka, S
    NEURORADIOLOGY, 2000, 42 (12) : 868 - 873
  • [25] Phase-contrast MR angiography of intracranial dural arteriovenous fistulae
    M. Cellerini
    M. Mascalchi
    S. Mangiafico
    G. P. Ferrito
    V. Scardigli
    G. Pellicanò
    N. Quilici
    Neuroradiology, 1999, 41 : 487 - 492
  • [26] Enhancement of phase-contrast MR angiography with superparamagnetic iron oxide
    Tanimoto, A
    Yuasa, Y
    Hiramatsu, K
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02): : 446 - 450
  • [27] Noninvasive Assessment of Transstenotic Pressure Gradients in Porcine Renal Artery Stenoses by Using Vastly Undersampled Phase-Contrast MR Angiography
    Bley, Thorsten A.
    Johnson, Kevin M.
    Francois, Christopher J.
    Reeder, Scott B.
    Schiebler, Mark L.
    Landgraf, Benjamin R.
    Consigny, Daniel
    Grist, Thomas M.
    Wieben, Oliver
    RADIOLOGY, 2011, 261 (01) : 266 - 273
  • [28] Phase-contrast MR angiography of intracranial dural arteriovenous fistulae
    Cellerini, M
    Mascalchi, M
    Mangiafico, S
    Ferrito, GP
    Scardigli, V
    Pellicanò, G
    Quilici, N
    NEURORADIOLOGY, 1999, 41 (07) : 487 - 492
  • [29] Phase-Contrast MR Imaging Support for the Diagnosis of Aqueductal Stenosis
    Sankari, S. Stoquart-El
    Lehmann, P.
    Gondry-Jouet, C.
    Fichten, A.
    Godefroy, O.
    Meyer, M. -E.
    Baledent, O.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (01) : 209 - 214
  • [30] MR angiography of arteriosclerotic carotid artery disease
    Fellner, FA
    Wutke, R
    Fellner, C
    Lang, W
    Laub, G
    Matzel, KE
    Bautz, WA
    NEW ASPECTS OF HIGH TECHNOLOGY IN MEDICINE, 2000, : 317 - 321