Analysis on Boiler Main Protection Logic of 600 MW Supercritical Unit

被引:0
|
作者
Pan Jin-jie [1 ]
Liu You-kuan [2 ]
Tian Pei [3 ]
机构
[1] Univ North China, Elect Power Co, Yunnan Power Grid Graduateworkstn, Kun Ming 650217, Peoples R China
[2] Yunnan Power Grid Power Res Inst, Kun Ming 650217, Peoples R China
[3] Univ North China, Elect Power, Grad Sch Automat, Baoding 071000, Peoples R China
关键词
FSSS; MFT; W-shape flame boiler; 600 MW supercritical unit;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces the function of Furnace Safeguard Supervisory System (FSSS) for the power plant of huadian zhenxiong of 600 MW supercritical unit of W-shape flame boiler. Proceeding detailed analysis for the trip on the boiler main fuel trip logical, and the investment conditions in the operation process. This is providing the reference for the same type boiler main protection function.
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [33] The Parallel and Process Control Technology of Axial Flow Fans in a 600MW Supercritical Boiler
    Lyu D.
    Bin Y.
    Li W.
    Jiang S.
    Zeng J.
    Liu S.
    Chen W.
    Xie G.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (17): : 5574 - 5582
  • [34] Research and application of condenser cathodic protection of 600MW unit
    Wuhan Shuili Dianli Daxue Xuebao, 5 (81-83):
  • [35] An experimental study on the hydrodynamic performance of the water-wall system of a 600 MW supercritical CFB boiler
    Chen, Ye
    Lu, Xiaofeng
    Zhang, Wenqing
    Wang, Quanhai
    Chen, Sida
    Fan, Xuchen
    Li, Jianbo
    APPLIED THERMAL ENGINEERING, 2018, 141 : 280 - 287
  • [36] Studies on heat flux distribution on the membrane walls in a 600 MW supercritical arch-fired boiler
    Zhang, Dalong
    Meng, Chenwei
    Zhang, Hai
    Liu, Pengyuan
    Li, Zhouhang
    Wu, Yuxin
    Lu, Junfu
    Zhou, Wu
    Ran, Shenming
    Zhang, Dinghai
    APPLIED THERMAL ENGINEERING, 2016, 103 : 264 - 273
  • [37] Numerical calculation of the temperature field of membrane waterwall in burner zone of 600MW supercritical boiler
    Li, Chun-Yan
    Yan, Wei-Ping
    Liang, Xiu-Jun
    Huang, Jing-Li
    Dongli Gongcheng/Power Engineering, 2008, 28 (05): : 677 - 681
  • [38] Study on Dynamic Characteristics of a 600MW Ultra-Supercritical Double-Reheat Boiler
    Wang, Zhu
    Liu, Ming
    Wang, Chaoyang
    Chong, Daotong
    Yan, Yunjie
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 5257 - 5262
  • [39] Experimental Study on the Heat-Transfer Characteristics of a 600 MW Supercritical Circulating Fluidized Bed Boiler
    Chen, Ye
    Lu, Xiaofeng
    Zhang, Wenqing
    Wang, Quanhai
    Chen, Sida
    Xu, Jie
    Yang, Yu
    Li, Jianbo
    ENERGY & FUELS, 2018, 32 (01) : 1 - 9
  • [40] Experimental and numerical study on air flow uniformity in the isobaric windbox of a 600 MW supercritical CFB boiler
    Yan, Jin
    Lu, Xiaofeng
    Wang, Quanhai
    Kang, Yinhu
    Li, Jianbo
    Zhou, Jinliang
    Zhang, Yi
    Lv, Zhuo
    Sun, Sicong
    APPLIED THERMAL ENGINEERING, 2017, 122 : 311 - 321